Non-invasive Hemoglobin Measurement Predictive Analytics with Missing Data and Accuracy Improvement Using Gaussian Process and Functional Regression Model

被引:1
|
作者
Man, Jianing [1 ,5 ]
Zielinski, Martin D. [2 ]
Das, Devashish [3 ]
Sir, Mustafa Y. [4 ]
Wutthisirisart, Phichet [5 ]
Camazine, Maraya [6 ]
Pasupathy, Kalyan S. [5 ,7 ]
机构
[1] Beijing Inst Technol, Inst Ind & Intelligent Syst Engn, Sch Mech Engn, Beijing, Peoples R China
[2] Baylor Coll Med, Dept Surg, Houston, TX 77030 USA
[3] Univ S Florida, Dept Ind & Management Syst Engn, Tempa, FL USA
[4] Amazon Com Inc, Seattle, WA USA
[5] Mayo Clin, Robert D & Patricia E Kern Ctr Sci Hlth Care Deli, Rochester, MN 55905 USA
[6] Mayo Clin, Dept Surg, Rochester, MN USA
[7] Univ Illinois, Dept Biomed & Hlth Informat Sci, Chicago, IL 60607 USA
关键词
Non-invasive hemoglobin measurement; Missing data; Functional regression method; Functional principal component analysis; Gaussian process; OXIMETRY; CARE;
D O I
10.1007/s10916-022-01854-8
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Recent use of noninvasive and continuous hemoglobin (SpHb) concentration monitor has emerged as an alternative to invasive laboratory-based hematological analysis. Unlike delayed laboratory based measures of hemoglobin (HgB), SpHb monitors can provide real-time information about the HgB levels. Real-time SpHb measurements will offer healthcare providers with warnings and early detections of abnormal health status, e.g., hemorrhagic shock, anemia, and thus support therapeutic decision-making, as well as help save lives. However, the finger-worn CO-Oximeter sensors used in SpHb monitors often get detached or have to be removed, which causes missing data in the continuous SpHb measurements. Missing data among SpHb measurements reduce the trust in the accuracy of the device, influence the effectiveness of hemorrhage interventions and future HgB predictions. A model with imputation and prediction method is investigated to deal with missing values and improve prediction accuracy. The Gaussian process and functional regression methods are proposed to impute missing SpHb data and make predictions on laboratory-based HgB measurements. Within the proposed method, multiple choices of sub-models are considered. The proposed method shows a significant improvement in accuracy based on a real-data study. Proposed method shows superior performance with the real data, within the proposed framework, different choices of sub-models are discussed and the usage recommendation is provided accordingly. The modeling framework can be extended to other application scenarios with missing values.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Non-invasive Hemoglobin Measurement Predictive Analytics with Missing Data and Accuracy Improvement Using Gaussian Process and Functional Regression Model
    Jianing Man
    Martin D. Zielinski
    Devashish Das
    Mustafa Y. Sir
    Phichet Wutthisirisart
    Maraya Camazine
    Kalyan S. Pasupathy
    [J]. Journal of Medical Systems, 46
  • [2] Improving non-invasive hemoglobin measurement accuracy using nonparametric models
    Man, Jianing
    Zielinski, Martin D.
    Das, Devashish
    Wutthisirisart, Phichet
    Pasupathy, Kalyan S.
    [J]. JOURNAL OF BIOMEDICAL INFORMATICS, 2022, 126
  • [3] Generalized Gaussian Process Regression Model for Non-Gaussian Functional Data
    Wang, Bo
    Shi, Jian Qing
    [J]. JOURNAL OF THE AMERICAN STATISTICAL ASSOCIATION, 2014, 109 (507) : 1123 - 1133
  • [4] Accuracy of non-invasive hemoglobin level measurement in the emergency department
    Aseri, Zohair Ahmed Ali Al
    Aldawood, Badr Abdulrahman
    Altamimi, Adel Abdullah
    Mosleh, Haytam Issa
    Qaw, Amnah Samir
    Albatran, Hawra Ibraheem
    AlMasri, Maram Mohammed
    AlRihan, Tasneem Muhammed
    AlAithan, Fatimah Bassem
    AlAssaf, Laura Suliaman
    [J]. AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2023, 64 : 200 - 203
  • [5] Non-Invasive Inference of Minute Ventilation Using Wearable ECG and Gaussian Process Regression
    Alam, Ridwan
    Peden, David B.
    Gong, Jiaqi
    Lach, John
    [J]. 2019 IEEE EMBS INTERNATIONAL CONFERENCE ON BIOMEDICAL & HEALTH INFORMATICS (BHI), 2019,
  • [6] Non-invasive hemoglobin measurement using optical method
    Ranjith, R.
    Priya, S.
    Dharshini, A. S. Kaviya
    Jeeva, J. B.
    [J]. HELIYON, 2024, 10 (15)
  • [7] Non-invasive hemoglobin measurement using embedded platform
    Pinto, Caje
    Parab, Jivan
    Naik, Gourish
    [J]. SENSING AND BIO-SENSING RESEARCH, 2020, 29
  • [8] Non-Invasive Hemoglobin Concentration Measurement Using MGGP-Based Model
    Golap, Md Asaf-uddowla
    Hashem, M. M. A.
    [J]. 2019 5TH INTERNATIONAL CONFERENCE ON ADVANCES IN ELECTRICAL ENGINEERING (ICAEE), 2019, : 1 - 6
  • [9] Cautious Model Predictive Control Using Gaussian Process Regression
    Hewing, Lukas
    Kabzan, Juraj
    Zeilinger, Melanie N.
    [J]. IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 2020, 28 (06) : 2736 - 2743
  • [10] Accuracy and trending of non-invasive hemoglobin measurement during different volume and perfusion statuses
    Adel, Abdelmoneim
    Awada, Wael
    Abdelhamid, Bassant
    Omar, Heba
    Abd El Dayem, Omnia
    Hasanin, Ahmed
    Rady, Ashraf
    [J]. JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2018, 32 (06) : 1025 - 1031