Accuracy and trending of non-invasive hemoglobin measurement during different volume and perfusion statuses

被引:26
|
作者
Adel, Abdelmoneim [1 ]
Awada, Wael [1 ,2 ]
Abdelhamid, Bassant [1 ]
Omar, Heba [1 ]
Abd El Dayem, Omnia [3 ]
Hasanin, Ahmed [1 ,4 ]
Rady, Ashraf [1 ]
机构
[1] Cairo Univ, Fac Med, Dept Anesthesia & Crit Care Med, 01 Elsarayah St, Cairo 11559, Egypt
[2] Al Ghad Int Coll Appl Hlth Sci, Dept Emergency Med, Riyadh, Saudi Arabia
[3] Cairo Univ, Dept Clin & Chem Pathol, Cairo, Egypt
[4] Elameen Hosp, Dept Crit Care Med, At Taif, Saudi Arabia
关键词
Hemoglobin; Masimo; Pulse co-oximetry; Non-invasive; Fluid responsiveness; PULSE CO-OXIMETRY; FLUID RESPONSIVENESS; TRAUMA PATIENTS; INDEX; METAANALYSIS; TRANSFUSION; STANDARD;
D O I
10.1007/s10877-018-0101-z
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The evolution of non-invasive hemoglobin measuring technology would save time and improve transfusion practice. The validity of pulse co-oximetry hemoglobin (SpHb) measurement in the perioperative setting was previously evaluated; however, the accuracy of SpHb in different volume statuses as well as in different perfusion states was not well investigated. The aim of this work is to evaluate the accuracy and trending of SpHb in comparison to laboratory hemoglobin (Lab-Hb) during acute bleeding and after resuscitation. Seventy patients scheduled for major orthopedic procedures with anticipated major blood loss were included. Radical-7 device was used for continuous assessment of SpHb, volume status [via pleth variability index (PVI)] and perfusion status [via perfusion index (PI)]. Lab-Hb and SpHb were measured at three time-points, a baseline reading, after major bleeding, and after resuscitation. Samples were divided into fluid-responsive and fluid non-responsive samples, and were also divided into high-PI and low-PI samples. Accuracy of SpHb was determined using Bland-Altman analysis. Trending of SpHb was evaluated using polar plot analysis. We obtained 210 time-matched readings. Fluid non-responsive samples were 106 (50.5%) whereas fluid responsive samples were 104 (49.5%). Excellent correlation was reported between Lab-Hb and SpHb (r=0.938). Excellent accuracy with moderate levels of agreement was also reported between both measures among all samples, fluid non-responsive samples, fluid-responsive samples, high-PI samples, and low-PI samples [Mean bias (limits of agreement): 0.01 (-1.33 and 1.34) g/dL, -0.08 (-1.27 and 1.11) g/dL, 0.09 (-1.36 and 1.54) g/dL, 0.01 (-1.34 to 1.31) g/dL, and 0.04 (-1.31 to 1.39) g/dL respectively]. Polar plot analysis showed good trending ability for SpHb as a follow up monitor. In conclusion, SpHb showed excellent correlation with Lab-Hb in fluid responders, fluid non-responders, low-PI, and high PI states. Despite a favorable mean bias of 0.01g/dL for SpHb, the relatively wide levels of agreement (-1.3 to 1.3g/dL) might limit its accuracy. SpHb showed good performance as a trend monitor.
引用
收藏
页码:1025 / 1031
页数:7
相关论文
共 50 条
  • [1] Accuracy and trending of non-invasive hemoglobin measurement during different volume and perfusion statuses
    Abdelmoneim Adel
    Wael Awada
    Bassant Abdelhamid
    Heba Omar
    Omnia Abd El Dayem
    Ahmed Hasanin
    Ashraf Rady
    [J]. Journal of Clinical Monitoring and Computing, 2018, 32 : 1025 - 1031
  • [2] Accuracy of non-invasive hemoglobin level measurement in the emergency department
    Aseri, Zohair Ahmed Ali Al
    Aldawood, Badr Abdulrahman
    Altamimi, Adel Abdullah
    Mosleh, Haytam Issa
    Qaw, Amnah Samir
    Albatran, Hawra Ibraheem
    AlMasri, Maram Mohammed
    AlRihan, Tasneem Muhammed
    AlAithan, Fatimah Bassem
    AlAssaf, Laura Suliaman
    [J]. AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2023, 64 : 200 - 203
  • [3] Validity of accuracy and trending ability of non-invasive continuous total hemoglobin measurement in complex spine surgery: a prospective cohort study
    Chang, Feng-Cheng
    Lin, Jr-Rung
    Liu, Fu-Chao
    [J]. BMC ANESTHESIOLOGY, 2019, 19 (1)
  • [4] Validity of accuracy and trending ability of non-invasive continuous total hemoglobin measurement in complex spine surgery: a prospective cohort study
    Feng-Cheng Chang
    Jr-Rung Lin
    Fu-Chao Liu
    [J]. BMC Anesthesiology, 19
  • [5] Improving non-invasive hemoglobin measurement accuracy using nonparametric models
    Man, Jianing
    Zielinski, Martin D.
    Das, Devashish
    Wutthisirisart, Phichet
    Pasupathy, Kalyan S.
    [J]. JOURNAL OF BIOMEDICAL INFORMATICS, 2022, 126
  • [6] Non-invasive haemodynamic monitoring. A choice between trending and accuracy
    Karnwal, A.
    Lippmann, M.
    Kakazu, C.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2015, 115 (03) : 470 - 471
  • [7] Non-invasive measurement of hemoglobin during cesarean hysterectomy: a case series
    Butwick, A. J.
    Hilton, G.
    Riley, E. T.
    Carvalho, B.
    [J]. INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 2011, 20 (03) : 240 - 245
  • [8] Non-invasive Measurement of Hemoglobin Content in Blood
    Nirupa, Lourdes Albina J.
    Kumar, Jagadeesh, V
    [J]. 2014 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2014, : 638 - 642
  • [9] Non-invasive sensor for an in vivo hemoglobin measurement
    Kraitl, Jens
    Timm, Ulrich
    Ewald, Hartmut
    Lewis, Elfed
    [J]. 2011 IEEE SENSORS, 2011, : 276 - 279
  • [10] Non-invasive Hemoglobin Measurement for Anemia Diagnosis
    Rochmanto, Raditya Artha
    Zakaria, Hasballah
    Alviana, Ratih Devi
    Shahib, Nurhalim
    [J]. 2017 4TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING, COMPUTER SCIENCE AND INFORMATICS (EECSI), 2017, : 125 - 129