ACCURACY OF IMPLANT IMPRESSIONS WITHOUT IMPRESSION COPINGS: A THREE-DIMENSIONAL ANALYSIS

被引:23
|
作者
Kwon, Joo-Hyun [1 ]
Son, Yong-Ha [2 ]
Han, Chong-Hyun [1 ]
Kim, Sunjai [1 ]
机构
[1] Yonsei Univ, Gangnam Severance Dent Hosp, Coll Dent, Dept Prosthodont, Seoul 135720, South Korea
[2] Yonsei Univ, Coll Dent, Seoul 135720, South Korea
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2011年 / 105卷 / 06期
关键词
IN-VITRO; COMPONENTS; PROSTHESES; PRECISION; SYSTEM; FIT;
D O I
10.1016/S0022-3913(11)60075-9
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Implant impressions without impression copings can be used for cement-retained implant restorations. A comparison of the accuracy of implant impressions with and without impression copings is needed. Purpose. The purpose of this study was to evaluate and compare the dimensional accuracy of implant definitive casts that are fabricated by implant impressions with and without impression copings. Material and methods. An acrylic resin maxillary model was fabricated, and 3 implant replicas were secured in the right second premolar, first, and second molars. Two impression techniques were used to fabricate definitive casts (n=10). For the coping group (Group C), open tray impression copings were used for the final impressions. For the no-coping group (Group NC), cementable abutments were connected to the implant replicas, and final impressions were made assuming the abutments were prepared teeth. Computerized calculation of the centroids and long axes of the implant or stone abutment replicas was performed. The Mann-Whitney U test analyzed the amount of linear and rotational distortion between groups (alpha = .05). Results. At the first molar site, Group NC showed significantly greater linear distortion along the Y-axis, with a small difference between the groups (Group C, 7.8 +/- 7.4 mu m; Group NC, 19.5 +/- 12.2). At the second molar site, increased distortion was noted in Group NC for every linear and rotational variable, except for linear distortion along the Z-axis. Conclusions. Implant impression with open tray impression copings produced more accurate definitive casts than those fabricated without impression copings, especially those with greater inter-abutment distance. (J Prosthet Dent 2011;105:367-373)
引用
收藏
页码:367 / 373
页数:7
相关论文
共 50 条
  • [21] Orthodontic elastomeric chain as an alternative to dental floss for splinting implant impression copings for complete-arch implant impressions
    Joshi, Amruta A.
    Gaikwad, Amit M.
    Nadgere, Jyoti B.
    Ram, Sabita M.
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (01): : 188 - 189
  • [22] A Comparative Study of the Accuracy between Plastic and Metal Impression Transfer Copings for Implant Restorations
    Fernandez, Monica A.
    de Mendoza, Carmen Y. Paez
    Platt, Jeffrey A.
    Levon, John A.
    Hovijitra, Suteera T.
    Nimmo, Arthur
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2013, 22 (05): : 367 - 376
  • [23] Volumetric evaluation and three-dimensional accuracy of different elastomeric impression materials
    Emir, Faruk
    Ayyildiz, Simel
    Piskin, Bulent
    Sipahi, Cumhur
    MEASUREMENT, 2018, 127 : 436 - 442
  • [24] Accuracy of Three Implant Impression Techniques with Different Impression Materials and Stones
    Chang, Won-Gun
    Vahidi, Farhad
    Bae, Kwang-Hak
    Lim, Bum-Soon
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2012, 25 (01) : 44 - 47
  • [25] A technique to splint and verify the accuracy of implant impression copings with light-polymerizing acrylic resin
    Rutkunas, Vygandas
    Dgnatovic, Jevgenija
    JOURNAL OF PROSTHETIC DENTISTRY, 2014, 111 (03): : 254 - 256
  • [26] Comparison of accuracy between digital and conventional implant impressions: two and three dimensional evaluations
    Bi, Chuang
    Wang, Xingyu
    Tian, Fangfang
    Qu, Zhe
    Zhao, Jiaming
    JOURNAL OF ADVANCED PROSTHODONTICS, 2022, 14 (04): : 236 - 249
  • [27] The impact of impression coping geometrical design on accuracy of implant impressions: an experimental study
    Motaz Osman
    Neamat Hassan Abubakr
    Ahmed Suliman
    Hassan Ziada
    International Journal of Implant Dentistry, 6
  • [28] The impact of impression coping geometrical design on accuracy of implant impressions: an experimental study
    Osman, Motaz
    Abubakr, Neamat Hassan
    Suliman, Ahmed
    Ziada, Hassan
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2020, 6 (01)
  • [29] In vitro comparative study between complete arch conventional implant impressions and digital implant scans with scannable pick-up impression copings
    Conejo, Julian
    Yoo, Thomas H.
    Atria, Pablo J.
    Fraiman, Howard
    Blatz, Markus B.
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (03): : 475e1 - 475e7
  • [30] Accuracy of two elastomeric impression materials in transferring Paragon® dental implants:: a three-dimensional analysis.
    Bravo-Cavicchioli, DA
    Elias-Boneta, AR
    Psoter, WJ
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : A334 - A334