Investigating in vivo airway wall mechanics during tidal breathing with optical coherence tomography

被引:15
|
作者
Robertson, Claire [1 ,2 ]
Lee, Sang-Won [3 ,4 ]
Ahn, Yeh-Chan [3 ,5 ]
Mahon, Sari [3 ]
Chen, Zhongping [1 ,2 ,3 ]
Brenner, Matthew [3 ,6 ]
George, Steven C. [1 ,2 ,7 ]
机构
[1] Univ Calif Irvine, Dept Biomed Engn, Irvine, CA 92697 USA
[2] Univ Calif Irvine, Edwards Lifesci Ctr Adv Cardiovasc Technol, Irvine, CA 92697 USA
[3] Univ Calif Irvine, Beckman Laser Inst, Irvine, CA 92612 USA
[4] Elect & Telecommun Res Inst, Taejon 305700, South Korea
[5] Pukyong Natl Univ, Dept Biomed Engn, Pusan 608737, South Korea
[6] Univ Calif Irvine, Div Pulm & Crit Care, Orange, CA 92868 USA
[7] Univ Calif Irvine, Dept Chem Engn & Mat Sci, Irvine, CA 92697 USA
关键词
airway compliance; mechanics; in vivo; optical coherence tomography; ULTRASONIC PALPATION; ELASTOGRAPHY; ASTHMA; OCT; DEFORMATION; DYNAMICS; STRAIN; LUNG;
D O I
10.1117/1.3642006
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Optical coherence tomography (OCT) is a nondestructive imaging technique offering high temporal and spatial resolution, which makes it a natural choice for assessing tissue mechanical properties. We have developed methods to mechanically analyze the compliance of the rabbit trachea in vivo using tissue deformations induced by tidal breathing, offering a unique tool to assess the behavior of the airways during their normal function. Four-hundred images were acquired during tidal breathing with a custom-built endoscopic OCT system. The surface of the tissue was extracted from a set of these images via image processing algorithms, filtered with a bandpass filter set at respiration frequency to remove cardiac and probe motion, and compared to ventilatory pressure to calculate wall compliance. These algorithms were tested on elastic phantoms to establish reliability and reproducibility. The mean tracheal wall compliance (in five animals) was 1.3 +/- 0.3x10(-5) (mm Pa)(-1). Unlike previous work evaluating airway mechanics, this new method is applicable in vivo, noncontact, and loads the trachea in a physiological manner. The technique may have applications in assessing airway mechanics in diseases such as asthma that are characterized by significant airway remodeling. (C) 2011 Society of Photo-Optical Instrumentation Engineers (SPIE). [DOI: 10.1117/1.3642006]
引用
收藏
页数:8
相关论文
共 50 条
  • [21] In vivo imaging of airway cilia and mucus clearance with micro-optical coherence tomography
    Chu, Kengyeh K.
    Unglert, Carolin
    Ford, Tim N.
    Cui, Dongyao
    Carruth, Robert W.
    Singh, Kanwarpal
    Liu, Linbo
    Birket, Susan E.
    Solomon, George M.
    Rowe, Steven M.
    Tearney, Guillermo J.
    BIOMEDICAL OPTICS EXPRESS, 2016, 7 (07): : 2494 - 2505
  • [22] Phenotyping airway disease with optical coherence tomography
    Coxson, Harvey O.
    Eastwood, Peter R.
    Williamson, Jonathan P.
    Sin, Don D.
    RESPIROLOGY, 2011, 16 (01) : 34 - 43
  • [23] Optical coherence tomography of the lung and lower airway
    Mikhail-Hanna, N
    Mukai, D
    El-Abbadi, NH
    Jung, WG
    Mina-Araghi, R
    Chen, ZP
    Colt, H
    Brenner, M
    CHEST, 2003, 124 (04) : 77S - 77S
  • [24] Reproducibility Of Optical Coherence Tomography Airway Imaging
    Kirby, M.
    Nickens, T.
    Ohtani, K.
    Lisbona, R. M. Lopez
    Lee, A. M. D.
    Phaipanich, T.
    Lane, P.
    MacAulay, C.
    Lam, S.
    Coxson, H. O.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2015, 191
  • [25] Reproducibility of optical coherence tomography airway imaging
    Kirby, Miranda
    Ohtani, Keishi
    Nickens, Taylor
    Lopez Lisbona, Rosa Maria
    Lee, Anthony M. D.
    Shaipanich, Tawimas
    Lane, Pierre
    MacAulay, Calum
    Lam, Stephen
    Coxson, Harvey O.
    BIOMEDICAL OPTICS EXPRESS, 2015, 6 (11): : 4365 - 4377
  • [26] Measuring airway dimensions during bronchoscopy using anatomical optical coherence tomography
    Williamson, J. P.
    Armstrong, J. J.
    McLaughlin, R. A.
    Noble, P. B.
    West, A. R.
    Becker, S.
    Curatolo, A.
    Noffsinger, W. J.
    Mitchell, H. W.
    Phillips, M. J.
    Sampson, D. D.
    Hillman, D. R.
    Eastwood, P. R.
    EUROPEAN RESPIRATORY JOURNAL, 2010, 35 (01) : 34 - 41
  • [27] In vivo characterisation of field pea stem wall thickness using optical coherence tomography
    Fang, Qi
    Castro-Urrea, Felipe A.
    Haederle, Felix
    Sanderson, Rowan W.
    Silva, Dilusha
    A. Cowling, Wallace
    Kennedy, Brendan F.
    PLANT METHODS, 2023, 19 (01)
  • [28] In vivo characterisation of field pea stem wall thickness using optical coherence tomography
    Qi Fang
    Felipe A. Castro-Urrea
    Felix Haederle
    Rowan W. Sanderson
    Dilusha Silva
    Wallace A. Cowling
    Brendan F. Kennedy
    Plant Methods, 19
  • [29] Identification And Quantification Of Airway Wall Layers With Optical Coherence Tomography: a Histology Based Validation Study
    D'Hooghe, J. N. S.
    De Bruin, D. M.
    Roelofs, J. J. T. H.
    Annema, J. T.
    Bonta, P. I.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2016, 193
  • [30] Fluid Challenge Induces Transient Airway Wall Edema Visualized Via Optical Coherence Tomography
    Thiboutot, J.
    Scott, W.
    Park, H.
    Li, X.
    Yarmus, L. B.
    Mitzner, W.
    Brown, R. H.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2018, 197