Measuring airway dimensions during bronchoscopy using anatomical optical coherence tomography

被引:55
|
作者
Williamson, J. P. [1 ,3 ]
Armstrong, J. J. [4 ]
McLaughlin, R. A. [4 ]
Noble, P. B. [6 ]
West, A. R. [5 ]
Becker, S. [4 ]
Curatolo, A. [4 ]
Noffsinger, W. J. [1 ]
Mitchell, H. W. [5 ]
Phillips, M. J. [2 ]
Sampson, D. D. [4 ]
Hillman, D. R. [1 ,7 ]
Eastwood, P. R. [1 ,3 ,7 ]
机构
[1] Sir Charles Gairdner Hosp, Dept Pulm Physiol, Perth, WA 6000, Australia
[2] Sir Charles Gairdner Hosp, Dept Resp Med, Perth, WA 6000, Australia
[3] Univ Western Australia, Sch Anat & Human Biol, Nedlands, WA 6009, Australia
[4] Univ Western Australia, Opt Biomed Engn Lab, Sch Elect Elect & Comp Engn, Nedlands, WA 6009, Australia
[5] Univ Western Australia, Sch Biomed Biomol & Chem Sci, Nedlands, WA 6009, Australia
[6] Telethon Inst Child Hlth Res, Div Clin Sci, Perth, WA, Australia
[7] W Australian Sleep Disorders Res Inst, Perth, WA, Australia
基金
英国医学研究理事会;
关键词
Airway dimensions; computed tomography; interventional bronchoscopy; optical coherence tomography; quantitative bronchoscopy; COMPUTED-TOMOGRAPHY; PHARYNGEAL SHAPE; SIZE; INDIVIDUALS; CALIBER; LUMEN; LUNG;
D O I
10.1183/09031936.00041809
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Airway dimensions are difficult to quantify bronchoscopically because of optical distortion and a limited ability to gauge depth. Anatomical optical coherence tomography (aOCT), a novel imaging technique, may overcome these limitations. This study evaluated the accuracy of aOCT against existing techniques in phantom, excised pig and in vivo human airways. Three comparative studies were performed: 1) micrometer-derived area measurements in 10 plastic tubes were compared with aOCT-derived area; 2) aOCT-derived airway compliance curves from excised pig airways were compared with curves derived using an endoscopic technique; and 3) airway dimensions from the trachea to subsegmental bronchi were measured using aOCT in four anaesthetised patients during bronchoscopy and compared with computed tomography (CT) measurements. Measurements in plastic tubes revealed aOCT to be accurate and reliable. In pig airways, aOCT-derived compliance measurements compared closely with endoscopic data. In human airways, dimensions measured with aOCT and CT correlated closely. Bland-Altman plots showed that aOCT diameter and area measurements were higher than CT measurements by 7.6% and 15.1%, respectively. Airway measurements using aOCT are accurate, reliable and compare favourably with existing imaging techniques. Using aOCT with conventional bronchoscopy allows real-time measurement of airway dimensions and could be useful clinically in settings where knowledge of airway calibre is required.
引用
下载
收藏
页码:34 / 41
页数:8
相关论文
共 50 条
  • [1] Regional Airway Compliance in Asthma Measured Using Anatomical Optical Coherence Tomography
    Williamson, J. P.
    Armstrong, J. J.
    McLaughlin, R. A.
    Sampson, D. D.
    Regli, A.
    Walsh, J. H.
    James, A. L.
    Noffsinger, W. J.
    Hillman, D. R.
    Eastwood, P. R.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2009, 179
  • [2] Respiratory gating of anatomical optical coherence tomography images of the human airway
    McLaughlin, Robert A.
    Armstrong, Julian J.
    Becker, Sven
    Walsh, Jennifer H.
    Jain, Arpit
    Hillman, David R.
    Eastwood, Peter R.
    Sampson, David D.
    OPTICS EXPRESS, 2009, 17 (08): : 6568 - 6577
  • [3] Autofluorescence bronchoscopy and optical coherence tomography
    Lam, Stephen
    JOURNAL OF THORACIC ONCOLOGY, 2007, 2 (08) : S237 - S238
  • [4] Optical coherence tomography in conjunction with bronchoscopy
    Rodrigues, Ascedio Jose
    Takimura, Celso Kiyochi
    Lemos Neto, Pedro Alves
    Figueiredo, Viviane Rossi
    JORNAL BRASILEIRO DE PNEUMOLOGIA, 2012, 38 (02) : 174 - 180
  • [5] Using Optical Coherence Tomography To Improve Diagnostic and Therapeutic Bronchoscopy
    Williamson, Jonathan P.
    McLaughlin, Robert A.
    Phillips, Martin J.
    Armstrong, Julian J.
    Becker, Sven
    Walsh, Jennifer H.
    Sampson, David D.
    Hillman, David R.
    Eastwood, Peter R.
    CHEST, 2009, 136 (01) : 272 - 276
  • [6] Imaging of the pediatric airway using optical coherence tomography
    Ridgway, James Matthew
    Ahuja, Gurpreet
    Guo, Shuguang
    Su, Jianping
    Mahmood, Usama
    Chen, Zhongping
    Wong, Brian
    LARYNGOSCOPE, 2007, 117 (12): : 2206 - 2212
  • [7] Measuring Airway Remodeling in Patients With Different COPD Staging Using Endobronchial Optical Coherence Tomography
    Ding, Ming
    Chen, Yu
    Guan, Wei-Jie
    Zhong, Chang-Hao
    Jiang, Mei
    Luo, Wei-Zhan
    Chen, Xiao-Bo
    Tang, Chun-Li
    Tang, Yan
    Jian, Qi-Ming
    Wang, Wei
    Li, Shi-Yue
    Zhong, Nan-Shan
    CHEST, 2016, 150 (06) : 1281 - 1290
  • [8] Airway narrowing assessed by anatomical optical coherence tomography in vitro: dynamic airway wall morphology and function
    Noble, Peter B.
    West, Adrian R.
    McLaughlin, Robert A.
    Armstrong, Julian J.
    Becker, Sven
    McFawn, Peter K.
    Williamson, Jonathan P.
    Eastwood, Peter R.
    Hillman, David R.
    Sampson, David D.
    Mitchell, Howard W.
    JOURNAL OF APPLIED PHYSIOLOGY, 2010, 108 (02) : 401 - 411
  • [9] Measuring biofoam anisotropy using optical coherence tomography
    Mac Intyre, Jonatan R.
    Raka, Doruntina
    Aydin, Mehmet
    Viitanen, Leevi
    Koivisto, Juha
    JOURNAL OF MATERIALS SCIENCE, 2022, 57 (25) : 11663 - 11672
  • [10] Measuring biofoam anisotropy using optical coherence tomography
    Jonatan R. Mac Intyre
    Doruntina Raka
    Mehmet Aydin
    Leevi Viitanen
    Juha Koivisto
    Journal of Materials Science, 2022, 57 : 11663 - 11672