Measuring airway dimensions during bronchoscopy using anatomical optical coherence tomography

被引:55
|
作者
Williamson, J. P. [1 ,3 ]
Armstrong, J. J. [4 ]
McLaughlin, R. A. [4 ]
Noble, P. B. [6 ]
West, A. R. [5 ]
Becker, S. [4 ]
Curatolo, A. [4 ]
Noffsinger, W. J. [1 ]
Mitchell, H. W. [5 ]
Phillips, M. J. [2 ]
Sampson, D. D. [4 ]
Hillman, D. R. [1 ,7 ]
Eastwood, P. R. [1 ,3 ,7 ]
机构
[1] Sir Charles Gairdner Hosp, Dept Pulm Physiol, Perth, WA 6000, Australia
[2] Sir Charles Gairdner Hosp, Dept Resp Med, Perth, WA 6000, Australia
[3] Univ Western Australia, Sch Anat & Human Biol, Nedlands, WA 6009, Australia
[4] Univ Western Australia, Opt Biomed Engn Lab, Sch Elect Elect & Comp Engn, Nedlands, WA 6009, Australia
[5] Univ Western Australia, Sch Biomed Biomol & Chem Sci, Nedlands, WA 6009, Australia
[6] Telethon Inst Child Hlth Res, Div Clin Sci, Perth, WA, Australia
[7] W Australian Sleep Disorders Res Inst, Perth, WA, Australia
基金
英国医学研究理事会;
关键词
Airway dimensions; computed tomography; interventional bronchoscopy; optical coherence tomography; quantitative bronchoscopy; COMPUTED-TOMOGRAPHY; PHARYNGEAL SHAPE; SIZE; INDIVIDUALS; CALIBER; LUMEN; LUNG;
D O I
10.1183/09031936.00041809
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Airway dimensions are difficult to quantify bronchoscopically because of optical distortion and a limited ability to gauge depth. Anatomical optical coherence tomography (aOCT), a novel imaging technique, may overcome these limitations. This study evaluated the accuracy of aOCT against existing techniques in phantom, excised pig and in vivo human airways. Three comparative studies were performed: 1) micrometer-derived area measurements in 10 plastic tubes were compared with aOCT-derived area; 2) aOCT-derived airway compliance curves from excised pig airways were compared with curves derived using an endoscopic technique; and 3) airway dimensions from the trachea to subsegmental bronchi were measured using aOCT in four anaesthetised patients during bronchoscopy and compared with computed tomography (CT) measurements. Measurements in plastic tubes revealed aOCT to be accurate and reliable. In pig airways, aOCT-derived compliance measurements compared closely with endoscopic data. In human airways, dimensions measured with aOCT and CT correlated closely. Bland-Altman plots showed that aOCT diameter and area measurements were higher than CT measurements by 7.6% and 15.1%, respectively. Airway measurements using aOCT are accurate, reliable and compare favourably with existing imaging techniques. Using aOCT with conventional bronchoscopy allows real-time measurement of airway dimensions and could be useful clinically in settings where knowledge of airway calibre is required.
引用
下载
收藏
页码:34 / 41
页数:8
相关论文
共 50 条
  • [21] Using optical coherence tomography (OCT) imaging in the evaluation of airway dynamics
    Szabari, Margit V.
    Kelly, Vanessa J.
    Applegate, Matthew B.
    Chee, Chunmin
    Tan, Khay M.
    Hariri, Lida P.
    Harris, R. Scott
    Winkler, Tilo
    Suter, Melissa J.
    ENDOSCOPIC MICROSCOPY XI; AND OPTICAL TECHNIQUES IN PULMONARY MEDICINE III, 2016, 9691
  • [22] Optical coherence tomography of the lung and lower airway
    Mikhail-Hanna, N
    Mukai, D
    El-Abbadi, NH
    Jung, WG
    Mina-Araghi, R
    Chen, ZP
    Colt, H
    Brenner, M
    CHEST, 2003, 124 (04) : 77S - 77S
  • [23] Phenotyping airway disease with optical coherence tomography
    Coxson, Harvey O.
    Eastwood, Peter R.
    Williamson, Jonathan P.
    Sin, Don D.
    RESPIROLOGY, 2011, 16 (01) : 34 - 43
  • [24] Reproducibility Of Optical Coherence Tomography Airway Imaging
    Kirby, M.
    Nickens, T.
    Ohtani, K.
    Lisbona, R. M. Lopez
    Lee, A. M. D.
    Phaipanich, T.
    Lane, P.
    MacAulay, C.
    Lam, S.
    Coxson, H. O.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2015, 191
  • [25] Reproducibility of optical coherence tomography airway imaging
    Kirby, Miranda
    Ohtani, Keishi
    Nickens, Taylor
    Lopez Lisbona, Rosa Maria
    Lee, Anthony M. D.
    Shaipanich, Tawimas
    Lane, Pierre
    MacAulay, Calum
    Lam, Stephen
    Coxson, Harvey O.
    BIOMEDICAL OPTICS EXPRESS, 2015, 6 (11): : 4365 - 4377
  • [26] Measuring the optical characteristics of medulloblastoma with optical coherence tomography
    Vuong, Barry
    Skowron, Patryk
    Kiehl, Tim-Rasmus
    Kyan, Matthew
    Garzia, Livia
    Sun, Cuiru
    Taylor, Michael D.
    Yang, Victor X. D.
    BIOMEDICAL OPTICS EXPRESS, 2015, 6 (04): : 1487 - 1501
  • [27] Multi-modal anatomical Optical Coherence Tomography and CT for in vivo Dynamic Upper Airway Imaging
    Balakrishnan, Santosh
    Bu, Ruofei
    Price, Hillel
    Zdanski, Carlton
    Oldenburg, Amy L.
    OPTICAL IMAGING, THERAPEUTICS, AND ADVANCED TECHNOLOGY IN HEAD AND NECK SURGERY AND OTOLARYNGOLOGY, 2017, 10039
  • [28] Measuring Intracellular Motion in Cancer Cells using Optical Coherence Tomography
    Zam, Azhar
    Kolios, Michael C.
    DYNAMICS AND FLUCTUATIONS IN BIOMEDICAL PHOTONICS XIII, 2016, 9707
  • [29] Assessing Airway Remodeling In Asthma And The Response To Allergen Using Optical Coherence Tomography
    Suter, M. J.
    Adams, D. C.
    Miller, A. J.
    Holz, J. A.
    Szabari, M. V.
    Hariri, L. P.
    Cho, J. L.
    Harris, R.
    Griffith, J. W.
    Hamilos, D. L.
    Luster, A. D.
    Medoff, B. D.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2017, 195
  • [30] Validation of Human Small Airway Measurements Using Endobronchial Optical Coherence Tomography
    Chen, Yu
    Ding, Ming
    Guan, Wei-jie
    Li, Shiyue
    Zhong, Nanshan
    CHEST, 2016, 149 (04) : 446A - 446A