Reduced cement volume does not affect screw stability in augmented pedicle screws

被引:19
|
作者
Weiser, Lukas [1 ]
Sellenschloh, Kay [2 ]
Pueschel, Klaus [3 ]
Morlock, Michael M. [2 ]
Viezens, Lennart [1 ]
Lehmann, Wolfgang [1 ]
Huber, Gerd [2 ]
机构
[1] Univ Med Ctr Gottingen, Dept Trauma Surg Orthopaed Surg & Plast Surg, Robert Koch Str 40, D-37099 Gottingen, Germany
[2] TUHH Hamburg Univ Technol, Inst Biomech, Hamburg, Germany
[3] Univ Med Ctr Hamburg Eppendorf, Inst Forens Med, Hamburg, Germany
关键词
Pedicle screw; Cement augmentation; Cement volume; CAPSI; Bone mineral density; BONE-MINERAL DENSITY; OSTEOPOROTIC SPINE; POLYMETHYLMETHACRYLATE AUGMENTATION; BIOMECHANICAL CHARACTERISTICS; FIXATION; INSTRUMENTATION; STRENGTH; LEAKAGE; FRACTURES; DISEASES;
D O I
10.1007/s00586-020-06376-w
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose Cement augmentation of pedicle screws is able to improve screw anchorage in osteoporotic vertebrae but is associated with a high complication rate. The goal of this study was to evaluate the impact of different cement volumes on pedicle screw fatigue strength. Methods Twenty-five human vertebral bodies (T12-L4) were collected from donors between 73 and 97 years of age. Bone density (BMD) was determined by quantitative computed tomography. Vertebral bodies were instrumented by conventional pedicle screws, and unilateral cement augmentation was performed. Thirteen vertebrae were augmented with a volume of 1 ml and twelve with a volume of 3 ml bone cement. A fatigue test was performed using a cranial-caudal sinusoidal, cyclic load (0.5 Hz) with increasing compression force (100 N + 0.1 N/cycles). Results The load to failure was 183.8 N for the non-augmented screws and was increased significantly to 268.1 N (p < 0.001) by cement augmentation. Augmentation with 1 ml bone cement increased the fatigue load by 41% while augmentation with 3 ml increased the failure load by 51% compared to the non-augmented screws, but there was no significant difference in fatigue loads between the specimens with screws augmented with 1 ml and screws augmented with 3 ml of bone cement (p = 0.504). Conclusion Cement augmentation significantly increases pedicle screw stability. The benefit of augmentation on screw anchorage was not significantly affected by reducing the applied volume of cement from 3 ml to 1 ml. Considering the high risk of cement leakage during augmentation, we recommend the usage of a reduced volume of 1 ml bone cement for each pedicle screw. Graphic Abstracts These slides can be retrieved under Electronic Supplementary Material . [GRAPHICS] .
引用
收藏
页码:1297 / 1303
页数:7
相关论文
共 50 条
  • [41] Does the Bone Cement Affect Miniscrew Stability?
    Ates, Mustafa B.
    Motro, Melih
    Kovan, Aysegul
    Acar, Yasemin Bahar
    Erverdi, Nejat
    Gulmez, Turgut
    TURKISH JOURNAL OF ORTHODONTICS, 2013, 26 (03) : 119 - 128
  • [42] Risk Factors for Adjacent Fractures After Cement-Augmented Thoracolumbar Pedicle Screw Instrumentation
    Schwarz, Falko
    Burckhart, Michaela
    Mclean, Aaron Lawson
    Kalff, Rolf
    Waschke, Albrecht
    INTERNATIONAL JOURNAL OF SPINE SURGERY, 2018, 12 (05): : 565 - 570
  • [43] Biomechanical study of lumbar pedicle screws: Does convergence affect axial pullout strength?
    Barber, JW
    Boden, SD
    Ganey, T
    Hutton, WC
    JOURNAL OF SPINAL DISORDERS, 1998, 11 (03): : 215 - 220
  • [44] EVALUATION OF THE INTRINSIC PROPERTIES OF PEDICLE SCREWS: DO DIAMETER, MANUFACTURING AND SCREW DESIGN AFFECT RESISTANCE AND/OR RESISTIVITY
    Limthongkul, Worawat
    Savage, Jason
    Nenonene, Emmanuel K.
    Karaikovic, Eldin E.
    BOSNIAN JOURNAL OF BASIC MEDICAL SCIENCES, 2009, 9 : S77 - S82
  • [45] Biomechanical performance of various cement-augmented cannulated pedicle screw designs for osteoporotic bones
    Tolunay T.
    Arslan K.
    Yaman O.
    Dalbayrak S.
    Demir T.
    Spine Deformity, 2015, 3 (3) : 205 - 210
  • [46] Clinical accuracy and initial experience with augmented reality-assisted pedicle screw placement: the first 205 screws
    Liu, Ann
    Jin, Yike
    Cottrill, Ethan
    Khan, Majid
    Westbroek, Erick
    Ehresman, Jeff
    Pennington, Zach
    Lo, Sheng-Fu L.
    Sciubba, Daniel M.
    Molina, Camilo A.
    Witham, Timothy F.
    JOURNAL OF NEUROSURGERY-SPINE, 2022, 36 (03) : 351 - 357
  • [47] Percutaneous Endovascular Retrieval of Large Cement Leakage into the Right Atrium Following Cement-Augmented Pedicle Screw Instrumentation
    Takahashi, Shinji
    Sohgawa, Etsuji
    Suzuki, Akinobu
    Yamamoto, Akira
    Sasaki, Ryo
    Tanaka, Katsuaki
    Terai, Hidetomi
    Hoshino, Masatoshi
    Toyoda, Hiromitsu
    Tamai, Koji
    Nakamura, Hiroaki
    SPINE SURGERY AND RELATED RESEARCH, 2021, 5 (06): : 446 - 449
  • [48] Biomechanical study of injectable hollow pedicle screws for PMMA augmentation in severely osteoporotic lumbar vertebrae: effect of PMMA distribution and volume on screw stability
    Liu, Da
    Sheng, Jun
    Wu, Hong-hua
    Kang, Xia
    Xie, Qing-yun
    Luo, Yang
    Zhou, Jiang-jun
    Zheng, Wei
    JOURNAL OF NEUROSURGERY-SPINE, 2018, 29 (06) : 639 - 646
  • [49] Cement augmented percutaneous iliosacral screws prevent screw loosening in the treatment of patients with fragility fractures of the pelvis
    Haveman, Roelien
    Link, Bjorn-Christian
    Beeres, Frank J. P.
    Babst, Reto
    SWISS MEDICAL WEEKLY, 2018, 148 : 7S - 7S
  • [50] Application of cement-augmented pedicle screws in elderly patients with spinal tuberculosis and severe osteoporosis: a preliminary study
    Gao, Shutao
    Hu, Yukun
    Mamat, Fulati
    Liang, Weidong
    Mamat, Mardan
    Xun, Chuanhui
    Zhang, Jian
    Sheng, Weibin
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)