Reduced cement volume does not affect screw stability in augmented pedicle screws

被引:19
|
作者
Weiser, Lukas [1 ]
Sellenschloh, Kay [2 ]
Pueschel, Klaus [3 ]
Morlock, Michael M. [2 ]
Viezens, Lennart [1 ]
Lehmann, Wolfgang [1 ]
Huber, Gerd [2 ]
机构
[1] Univ Med Ctr Gottingen, Dept Trauma Surg Orthopaed Surg & Plast Surg, Robert Koch Str 40, D-37099 Gottingen, Germany
[2] TUHH Hamburg Univ Technol, Inst Biomech, Hamburg, Germany
[3] Univ Med Ctr Hamburg Eppendorf, Inst Forens Med, Hamburg, Germany
关键词
Pedicle screw; Cement augmentation; Cement volume; CAPSI; Bone mineral density; BONE-MINERAL DENSITY; OSTEOPOROTIC SPINE; POLYMETHYLMETHACRYLATE AUGMENTATION; BIOMECHANICAL CHARACTERISTICS; FIXATION; INSTRUMENTATION; STRENGTH; LEAKAGE; FRACTURES; DISEASES;
D O I
10.1007/s00586-020-06376-w
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose Cement augmentation of pedicle screws is able to improve screw anchorage in osteoporotic vertebrae but is associated with a high complication rate. The goal of this study was to evaluate the impact of different cement volumes on pedicle screw fatigue strength. Methods Twenty-five human vertebral bodies (T12-L4) were collected from donors between 73 and 97 years of age. Bone density (BMD) was determined by quantitative computed tomography. Vertebral bodies were instrumented by conventional pedicle screws, and unilateral cement augmentation was performed. Thirteen vertebrae were augmented with a volume of 1 ml and twelve with a volume of 3 ml bone cement. A fatigue test was performed using a cranial-caudal sinusoidal, cyclic load (0.5 Hz) with increasing compression force (100 N + 0.1 N/cycles). Results The load to failure was 183.8 N for the non-augmented screws and was increased significantly to 268.1 N (p < 0.001) by cement augmentation. Augmentation with 1 ml bone cement increased the fatigue load by 41% while augmentation with 3 ml increased the failure load by 51% compared to the non-augmented screws, but there was no significant difference in fatigue loads between the specimens with screws augmented with 1 ml and screws augmented with 3 ml of bone cement (p = 0.504). Conclusion Cement augmentation significantly increases pedicle screw stability. The benefit of augmentation on screw anchorage was not significantly affected by reducing the applied volume of cement from 3 ml to 1 ml. Considering the high risk of cement leakage during augmentation, we recommend the usage of a reduced volume of 1 ml bone cement for each pedicle screw. Graphic Abstracts These slides can be retrieved under Electronic Supplementary Material . [GRAPHICS] .
引用
收藏
页码:1297 / 1303
页数:7
相关论文
共 50 条
  • [31] Cement-Augmented Pedicle Screw Fixation in Patients with Osteoporosis : Safety, Efficacy and Complications
    Olbrycht, Tomasz
    Latka, Kajetan
    Kolodziej, Waldemar
    Krzeszowiec, Tomasz
    Latka, Dariusz
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2025, 68 (02) : 127 - 136
  • [32] Surgical Treatment of Scoliosis in Osteogenesis Imperfecta With Cement-augmented Pedicle Screw Instrumentation
    Yilmaz, Guney
    Hwang, Steven
    Oto, Murat
    Kruse, Richard
    Rogers, Kenneth J.
    Bober, Michael B.
    Cahill, Patrick J.
    Shah, Suken A.
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2014, 27 (03): : 174 - 180
  • [33] Correlation of pull-out strength of cement-augmented pedicle screws with CT-volumetric measurement of cement
    Foelsch, Christian
    Goost, Hans
    Figiel, Jens
    Paletta, Juergen R. J.
    Schultz, Wolfgang
    Lakemeier, Stefan
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2012, 57 (06): : 473 - 480
  • [34] Risk of cement leakage and pulmonary embolism by bone cement-augmented pedicle screw fixation of the thoracolumbar spine
    Janssen, Insa
    Ryang, Yu-Mi
    Gempt, Jens
    Bette, Stefanie
    Gerhardt, Julia
    Kirschke, Jan S.
    Meyer, Bernhard
    SPINE JOURNAL, 2017, 17 (06): : 837 - 844
  • [35] Insufficient stability of pedicle screws in osteoporotic vertebrae: biomechanical correlation of bone mineral density and pedicle screw fixation strength
    Lukas Weiser
    Gerd Huber
    Kay Sellenschloh
    Lennart Viezens
    Klaus Püschel
    Michael M. Morlock
    Wolfgang Lehmann
    European Spine Journal, 2017, 26 : 2891 - 2897
  • [36] Insufficient stability of pedicle screws in osteoporotic vertebrae: biomechanical correlation of bone mineral density and pedicle screw fixation strength
    Weiser, Lukas
    Huber, Gerd
    Sellenschloh, Kay
    Viezens, Lennart
    Pueschel, Klaus
    Morlock, Michael M.
    Lehmann, Wolfgang
    EUROPEAN SPINE JOURNAL, 2017, 26 (11) : 2891 - 2897
  • [37] A meta-analysis of complications associated with the use of cement-augmented pedicle screws in osteoporosis of spine
    Zhang, Jinlong
    Wang, Guohua
    Zhang, Nannan
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2021, 107 (07)
  • [38] Fenestrated pedicle screws for cement-augmented purchase in patients with bone softening: A review of 21 cases
    Amendola L.
    Gasbarrini A.
    Fosco M.
    Simoes C.E.
    Terzi S.
    De Iure F.
    Boriani S.
    Journal of Orthopaedics and Traumatology, 2011, 12 (4) : 193 - 199
  • [39] Thoracic pedicle screw insertion in Asian cadaveric specimen: does radiological pedicle profile affect outcome?
    Chris Yin Wei Chan
    Mun Keong Kwan
    Lim Beng Saw
    Surgical and Radiologic Anatomy, 2011, 33 : 19 - 25
  • [40] Thoracic pedicle screw insertion in Asian cadaveric specimen: does radiological pedicle profile affect outcome?
    Chan, Chris Yin Wei
    Kwan, Mun Keong
    Saw, Lim Beng
    SURGICAL AND RADIOLOGIC ANATOMY, 2011, 33 (01) : 19 - 25