Simulation of gamma-ray semiconductor detector generally makes assumptions such as electric field uniformity, constancy of mobilities and trapping times respect to electric field, etc. At least a part of these assumptions are not valid. A way to overcome this problem is to measure the collection efficiency as a function of depth directly. By a particular version of the micro-IBIC technique we measured the collection efficiency on a section of a CdTe detector and we used the experimental data as input for the Monte Carlo code ISIDE for simulating pulse height spectra produced by Co-57. The results obtained by this more realistic approach are presented and can be compared both with other kinds of simulations and with available experimental data.
引用
收藏
页码:145 / 147
页数:3
相关论文
共 50 条
  • [41] Radiation Detectors for X-Ray and Gamma-Ray Spectroscopy
    G. F. Knoll
    Journal of Radioanalytical and Nuclear Chemistry, 2000, 243 : 125 - 131
  • [42] Radiation detectors for X-ray and gamma-ray spectroscopy
    Knoll, GF
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2000, 243 (01) : 125 - 131
  • [43] Gamma-ray burst afterglows from realistic fireballs
    Dai, ZG
    Huang, YF
    Lu, T
    ASTROPHYSICAL JOURNAL, 1999, 520 (02): : 634 - 640
  • [44] MONTE-CARLO SIMULATION OF GAMMA-RAY SPECTRA FROM SEMICONDUCTOR-DETECTORS
    OLSCHNER, F
    LUND, JC
    STERN, I
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) : 1176 - 1179
  • [45] AN ANALYTICAL SIMULATION TO CALIBRATE GAMMA-RAY CYLINDRICAL DETECTORS FOR ENVIRONMENTAL AND RADIOACTIVE WASTE MEASUREMENTS
    Nafee, Sherif S.
    NUCLEAR TECHNOLOGY, 2010, 172 (02) : 211 - 219
  • [46] Wafer-Bonded Silicon Gamma-Ray Detectors
    Wulf, Eric A.
    Hobart, Karl D.
    Kub, Francis J.
    Kurfess, James D.
    Phlips, Bernard F.
    Tadjer, Marko
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 1624 - 1629
  • [47] Electrode configuration and energy resolution in gamma-ray detectors
    Luke, PN
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 380 (1-2): : 232 - 237
  • [48] GAMMA-RAY SPECTROMETRY WITH THICK MERCURIC IODIDE DETECTORS
    BEYERLE, A
    HULL, K
    MARKAKIS, J
    LOPEZ, B
    SZYMCZYK, WM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 213 (01): : 107 - 113
  • [49] Wafer-bonded silicon gamma-ray detectors
    Wulf, Eric A.
    Hobart, Karl D.
    Kub, Francis J.
    Mitchell, Lee J.
    Phlips, Bernard F.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 1531 - +
  • [50] Comparison of the gamma-ray burst sensitivity of different detectors
    Band, DL
    ASTROPHYSICAL JOURNAL, 2003, 588 (02): : 945 - 951