AN ANALYTICAL SIMULATION TO CALIBRATE GAMMA-RAY CYLINDRICAL DETECTORS FOR ENVIRONMENTAL AND RADIOACTIVE WASTE MEASUREMENTS

被引:2
|
作者
Nafee, Sherif S. [1 ,2 ]
机构
[1] Univ Alexandria, Dept Phys, Fac Sci, Alexandria 21121, Egypt
[2] King Abdullaziz Univ, Dept Phys, Fac Sci, Jeddah 21589, Saudi Arabia
关键词
HPGe detectors; self-attenuation; coincidence summing corrections; INCLUDING SELF-ABSORPTION; COINCIDENCE CORRECTIONS; EFFICIENCY; HPGE;
D O I
10.13182/NT10-A10906
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The calibration of gamma-ray cylindrical detectors is often required in the analysis of high or low environmental samples and the homogenously distributive nuclear waste drums. Therefore, a new analytical simulation method is proposed in the present work to calculate the full-energy peak efficiencies of high-purity germanium cylindrical detectors using extended sources of low and high volumes. The sources were mounted at three different positions with respect to the detector's axis (coaxial, parallel, and perpendicular), labeled as Position 1, Position 2, and Position 3, respectively. The self-attenuation and the coincidence summing effects at low source-detector distance are also included in the algorithm. A remarkable agreement between the measured and the calculated efficiencies is achieved with discrepancies <4% for the first two positions and between 5 and 7% for the last one.
引用
收藏
页码:211 / 219
页数:9
相关论文
共 50 条
  • [1] Probability correction for the analytical simulation approach to calibrating γ-ray cylindrical detectors for environmental measurements
    Nafee, S. Sherif
    APPLIED RADIATION AND ISOTOPES, 2011, 69 (07) : 1019 - 1026
  • [2] GE(LI) GAMMA-RAY DETECTORS FOR ENVIRONMENTAL ACTIVITY MEASUREMENTS
    WALFORD, GV
    HEALTH PHYSICS, 1970, 19 (01): : 171 - +
  • [3] A realistic simulation of gamma-ray detectors
    Manfredotti, C
    Fizzotti, F
    Polesello, P
    Vittone, E
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 380 (1-2): : 145 - 147
  • [4] ENVIRONMENTAL GAMMA-RAY MEASUREMENTS
    DICKSON, HW
    ABDULLAH, SA
    FOX, WF
    HEALTH PHYSICS, 1974, 27 (06): : 631 - 631
  • [5] Realistic simulation of gamma-ray detectors
    Univ of Torino, Torino, Italy
    Nucl Instrum Methods Phys Res Sect A, 1-2 (145-147):
  • [6] SIMULATION OF THE TOTAL EFFICIENCY OF CYLINDRICAL SCINTILLATION GAMMA-RAY DETECTORS FOR DISK SOURCES
    Rehman, Shakeel U.
    Mirza, Sikander M.
    Mirza, Nasir M.
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2010, 25 (02): : 85 - 92
  • [7] ENVIRONMENTAL GAMMA-RAY MEASUREMENTS WITH TLDS
    ISHIKAWA, Y
    WATANABE, T
    ICHIKAWA, K
    HEALTH PHYSICS, 1985, 49 (02): : 378 - 378
  • [8] LaCl3:Ce coincidence signatures to calibrate gamma-ray detectors
    McIntyre, Justin I.
    Schrom, Brian T.
    Cooper, Mathew W.
    Day, Anthony
    Hayes, James C.
    Heimbigner, Tom R.
    Hubbard, Charles W.
    Ripplinger, Michael D.
    Suarez, Reynold
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 652 (01): : 201 - 204
  • [9] RADIOACTIVE STANDARDS FOR CALIBRATION OF GERMANIUM DETECTORS FOR GAMMA-RAY SPECTROMETRY
    DEBERTIN, K
    SCHOTZIG, U
    WALZ, KF
    WEISS, HM
    PTB-MITTEILUNGEN, 1977, 87 (01): : 22 - 26
  • [10] Simulation studies of CZT detectors as gamma-ray calorimeter
    Jung, I.
    Krawczynski, H.
    Komarov, S.
    Sobotka, L.
    ASTROPARTICLE PHYSICS, 2006, 26 (02) : 119 - 128