AN ANALYTICAL SIMULATION TO CALIBRATE GAMMA-RAY CYLINDRICAL DETECTORS FOR ENVIRONMENTAL AND RADIOACTIVE WASTE MEASUREMENTS

被引:2
|
作者
Nafee, Sherif S. [1 ,2 ]
机构
[1] Univ Alexandria, Dept Phys, Fac Sci, Alexandria 21121, Egypt
[2] King Abdullaziz Univ, Dept Phys, Fac Sci, Jeddah 21589, Saudi Arabia
关键词
HPGe detectors; self-attenuation; coincidence summing corrections; INCLUDING SELF-ABSORPTION; COINCIDENCE CORRECTIONS; EFFICIENCY; HPGE;
D O I
10.13182/NT10-A10906
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The calibration of gamma-ray cylindrical detectors is often required in the analysis of high or low environmental samples and the homogenously distributive nuclear waste drums. Therefore, a new analytical simulation method is proposed in the present work to calculate the full-energy peak efficiencies of high-purity germanium cylindrical detectors using extended sources of low and high volumes. The sources were mounted at three different positions with respect to the detector's axis (coaxial, parallel, and perpendicular), labeled as Position 1, Position 2, and Position 3, respectively. The self-attenuation and the coincidence summing effects at low source-detector distance are also included in the algorithm. A remarkable agreement between the measured and the calculated efficiencies is achieved with discrepancies <4% for the first two positions and between 5 and 7% for the last one.
引用
收藏
页码:211 / 219
页数:9
相关论文
共 50 条
  • [21] Simulation and experimental results on monolithic CdZnTe gamma-ray detectors
    d'Aillon, EG
    Gentet, MC
    Montémont, G
    Rustique, J
    Verger, L
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (06) : 3096 - 3102
  • [22] CHARACTERIZATION OF FRACTURES USING DIRECTIONAL GAMMA-RAY DETECTORS AND RADIOACTIVE-TRACERS
    REIS, JC
    IDREES, M
    NUCLEAR GEOPHYSICS, 1992, 6 (04): : 487 - 497
  • [23] The collimator shape design of segmented gamma-ray scanning for radioactive waste
    Hou Suxia
    Luo Jijun
    Li Rusong
    Wang Yongcang
    ANNALS OF NUCLEAR ENERGY, 2020, 135
  • [24] Calibration of HPGe gamma-ray detectors for measurement of radioactive noble gas sources
    Pibida, L.
    Nafee, S. S.
    Unterweger, M.
    Hammond, M. M.
    Karam, L.
    Abbas, M. I.
    APPLIED RADIATION AND ISOTOPES, 2007, 65 (02) : 225 - 233
  • [25] Spectrum shape analysis applied to radioactive waste gamma-ray spectroscopy
    Perot, B
    Artaud, JL
    Chabalier, B
    Misraki, J
    Chany, P
    ADVANCED MONTE CARLO FOR RADIATION PHYSICS, PARTICLE TRANSPORT SIMULATION AND APPLICATIONS, 2001, : 413 - 418
  • [26] ANALYTICAL PEAK FITTING FOR GAMMA-RAY SPECTRUM ANALYSIS WITH GE DETECTORS
    HAMMED, MA
    GRAY, PW
    NABOULSI, AH
    MACMAHON, TD
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 334 (2-3): : 543 - 550
  • [27] ANALYTICAL PEAK FITTING FOR GAMMA-RAY SPECTRUM ANALYSIS WITH GE DETECTORS
    LONGORIA, LC
    NABOULSI, AH
    GRAY, PW
    MACMAHON, TD
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 299 (1-3): : 308 - 312
  • [28] NEED FOR CYLINDRICAL GERMANIUM GAMMA-RAY DETECTORS WITH ACCURATELY SPECIFIED DIMENSIONS.
    Moens, L.
    Debertin, K.
    Nuclear instruments and methods in physics research, 1985, A238 (01): : 180 - 181
  • [29] Simulation of the radiation fallout from gamma-ray measurements
    Gusev A.A.
    Martin I.M.
    Alves M.A.
    de Abreu A.J.
    Modeling Earth Systems and Environment, 2015, 1 (3)
  • [30] A STANDARD TO CALIBRATE GAMMA-RAY SPECTROMETERS FOR GASEOUS SAMPLES
    OLSON, DG
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1984, 35 (08): : 755 - &