Probability correction for the analytical simulation approach to calibrating γ-ray cylindrical detectors for environmental measurements

被引:2
|
作者
Nafee, S. Sherif [1 ,2 ]
机构
[1] Univ Alexandria, Fac Sci, Dept Phys, Alexandria 21121, Egypt
[2] King Abdullaziz Univ, Fac Sci, Dept Phys, Jeddah 21589, Saudi Arabia
关键词
Marinelli beaker; gamma-ray detectors; Self-attenuation; Coincidence summing corrections; COINCIDENCE CORRECTIONS; EXTENDED SOURCES; PEAK EFFICIENCY; HPGE DETECTORS; SAMPLES;
D O I
10.1016/j.apradiso.2011.03.007
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Marinelli beakers increase geometric efficiency of detection in the gamma-spectrometry of low-activity environmental samples by positioning the sample in close proximity to the detector. A probability correction has been introduced to the analytical simulation approach proposed previously (Nafee et al., 2009) for calculating detection efficiencies of gamma-ray cylindrical detectors using extended low- and high-volume Marinelli beakers. Improved expressions for the self-attenuation and the coincidence summing effects at short source-detector distances have also been included in the analytical algorithm. A remarkable agreement between the measured and calculated efficiencies was observed as a result. Deviations of results calculated in this way from experimental values are twice as small as were observed with the previously reported analytical methods (Abbas, 2001; Nafee et al., 2009). (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1019 / 1026
页数:8
相关论文
共 33 条
  • [1] AN ANALYTICAL SIMULATION TO CALIBRATE GAMMA-RAY CYLINDRICAL DETECTORS FOR ENVIRONMENTAL AND RADIOACTIVE WASTE MEASUREMENTS
    Nafee, Sherif S.
    NUCLEAR TECHNOLOGY, 2010, 172 (02) : 211 - 219
  • [2] PROBABILITY CORRECTION APPROACH TO CALIBRATE HIGH-PURITY GERMANIUM CYLINDRICAL DETECTORS USING PARALLELEPIPED SOURCES
    Nafee, Sherif S.
    NUCLEAR TECHNOLOGY, 2014, 187 (03) : 328 - 336
  • [3] Simple analytical formula to calculate γ-ray cylindrical detectors efficiencies
    Hamzawy, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 624 (01): : 125 - 129
  • [4] A NEW APPROACH TO CALIBRATING FOR DISTANCE-AMPLITUDE CORRECTION IN ULTRASONIC FLAW DETECTORS
    JACKSON, JL
    RUMBOLD, JG
    MATERIALS EVALUATION, 1979, 37 (10) : P5 - P5
  • [5] ANALYTICAL APPROACH TO ENVIRONMENTAL RADIATION MEASUREMENTS
    STEPHENS, LD
    SMITH, AR
    THOMAS, RH
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1976, 23 (01) : 719 - 725
  • [6] GE(LI) GAMMA-RAY DETECTORS FOR ENVIRONMENTAL ACTIVITY MEASUREMENTS
    WALFORD, GV
    HEALTH PHYSICS, 1970, 19 (01): : 171 - +
  • [7] SIMULATION OF THE TOTAL EFFICIENCY OF CYLINDRICAL SCINTILLATION GAMMA-RAY DETECTORS FOR DISK SOURCES
    Rehman, Shakeel U.
    Mirza, Sikander M.
    Mirza, Nasir M.
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2010, 25 (02): : 85 - 92
  • [8] Application of GEANT4 simulation on calibration of HPGe detectors for cylindrical environmental samples
    Nikolic, J. D.
    Jokovic, D.
    Todorovic, D.
    Rajacic, M.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2014, 34 (02) : N47 - N55
  • [9] An approach to evaluate the efficiency of γ-ray detectors to determine the radioactivity in environmental samples
    Mohamed.S.Badawi
    Ahmed.M.El-Khatib
    Samah.M.Diab
    Sherif.S.Nafee
    Ekram.A.El-Mallah
    Chinese Physics C, 2014, (06) : 66 - 72
  • [10] An approach to evaluate the efficiency of γ-ray detectors to determine the radioactivity in environmental samples
    Badawi, Mohamed. S.
    El-Khatib, Ahmed M.
    Diab, Samah. M.
    Nafee, Sherif. S.
    El-Mallah, Ekram. A.
    CHINESE PHYSICS C, 2014, 38 (06)