Evaluation of a newly developed visual shade-matching apparatus

被引:0
|
作者
Paravina, RD
机构
关键词
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This study evaluated a newly developed visual shade-matching apparatus, Shademat Visual+, as well as the influence of tab arrangement, clinician gender, and years in practice on shade-matching quality. Materials and Methods: A group of 129 color-normal evaluators-dental students and general dentists-matched the shade of four ceramometal crowns using the Vitapan Classical shade guide. Crowns were positioned onto the upper member of an artificial head and fastened to the headrest of the dental chair or Shademat Visual+. Shade tabs were arranged according to the manufacturer's suggestion or according to DeltaE* in relation to the "lightest" tab and divided into groups (alternative arrangement). The evaluators matched the shade of four ceramometal crowns both in daylight and using the Shadernat Visual+ artificial light source. The color coordinates were determined using digital image analysis. Based on DeltaE* values, each shade-matching result was ranked from I (the worst match) to 16 (the best match) points. Results: The evaluators achieved a better result in Shadernat Visual+ trials than in daylight trials (13.2 points vs 12.4 points; P < .001). For the same ceramometal crown, 12.7 points were recorded in daylight trials with the manufacturer-suggested arrangement, and 13.7 were recorded with the alternative arrangement (P < .001). Corresponding values for Shademat Visual+ trials were 13.6 points and 14.6 points, respectively (P < .001). Female-male and student-dentist evaluator differences were not significant. Conclusion: The Shadernat Visual+ apparatus enabled better shade-matching results than daylight. The alternative tab arrangement enabled better results than the manufacturer-suggested one. Gender and years in practice did not influence shade-matching quality.
引用
收藏
页码:528 / 534
页数:7
相关论文
共 50 条
  • [41] Evaluation of shade matching in the repair of indirect restorative materials with universal shade composites
    Gencer, Busra Karabulut
    Acar, Ezgi
    Tarcin, Bilge
    EUROPEAN ORAL RESEARCH, 2023, 57 (01) : 41 - 48
  • [42] Performance report of a newly developed slow positron pulsing apparatus
    Graduate Univ for Advanced Studies, Ibaraki, Japan
    Mater Sci Forum, (629-631):
  • [43] A systematic review of visual and instrumental measurements for tooth shade matching
    Chen, Hui
    Huang, Jing
    Dong, Xian
    Qian, Jielei
    He, Jiajing
    Qu, Xinhua
    Lu, Eryi
    QUINTESSENCE INTERNATIONAL, 2012, 43 (08): : 649 - 659
  • [44] Comparison of shade matching by visual observation and an intraoral dental colorimeter
    Li, Q.
    Wang, Y. N.
    JOURNAL OF ORAL REHABILITATION, 2007, 34 (11) : 848 - 854
  • [45] Performance report of a newly developed slow positron pulsing apparatus
    Oshima, N
    Hamada, E
    Suzuki, T
    Kanazawa, I
    Ito, Y
    POSITRON ANNIHILATION: ICPA-11 - PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON POSITRON ANNIHILATION, KANSAS CITY, MISSOURI, USA, MAY 1997, 1997, 255-2 : 629 - 631
  • [46] Shade Matching of OMNICHROMA Analyzed by Four Digital and Visual Shade Selection Techniques: An In Vitro Study
    Al-Hadithi, Abdalwahab
    Gholam, Mohammed
    DENTAL HYPOTHESES, 2022, 13 (04): : 124 - 127
  • [47] In Vivo Evaluations of Inter-Observer Reliability Using VITA Easyshade (R) Advance 4.0 Dental Shade-Matching Device
    Zlataric, Dubravka Knezovic
    Illes, Davor
    Alajbeg, Iva Z.
    Zagar, Maja
    ACTA STOMATOLOGICA CROATICA, 2016, 50 (01) : 34 - 39
  • [48] Performance evaluation of TBM clogging potential for plain and conditioning soil using a newly developed laboratory apparatus
    Kang, Chao
    Yi, Yaolin
    Bayat, Alireza
    INTERNATIONAL JOURNAL OF GEOTECHNICAL ENGINEERING, 2020, 14 (05) : 463 - 472
  • [49] Evaluation of Shade Matching Accuracy of Smartphone Application compared to Conventional Visual Method: An Observational Pilot Study
    Hari, Tumma Sri
    Thonse, Ektha Pai
    Hallikerimath, Rajendra B.
    Melavanki, Chithra L.
    Nayak, Ajay Kumar
    Ruttonji, Z. A. R. I. R.
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2022, 16 (12) : ZC27 - ZC31
  • [50] Evaluation of a newly developed biological patch
    Sung, HW
    Chang, Y
    Chiu, YT
    Lu, JH
    Hsu, HL
    Shih, CC
    ADVANCED BIOMATERIALS IN BIOMEDICAL ENGINEERING AND DRUG DELIVERY SYSTEMS, 1996, : 249 - 250