Absolute determination of chemical kinetic rate constants by optical tracking the reaction on the second timescale using cavity-enhanced absorption spectroscopy

被引:2
|
作者
Yi, Hongming [1 ]
Meng, Lingshuo [1 ,2 ]
Wu, Tao [3 ]
Lauraguais, Amelie [1 ]
Coeur, Cecile [1 ]
Tomas, Alexandre [2 ]
Fu, Hongbo [4 ]
Gao, Xiaoming [5 ]
Chen, Weidong [1 ]
机构
[1] Univ Littoral Cote dOpale, Lab Physicochim Atmosphere, F-59140 Dunkerque, France
[2] Univ Lille, Ctr Energy & Environm, Inst Mines Telecom, IMT Nord Europe, F-59000 Lille, France
[3] Nanchang Hangkong Univ, Key Lab Nondestruct Test, Nanchang 330063, Jiangxi, Peoples R China
[4] Fudan Univ, Inst Atmospher Sci, Shanghai Key Lab Atmospher Particle Pollut & Prev, Shanghai 200433, Peoples R China
[5] Chinese Acad Sci, Anhui Inst Opt & Fine Mech, Hefei 230031, Peoples R China
关键词
GAS-PHASE REACTIONS; NO3 RADICAL REACTIONS; ATMOSPHERIC CHEMISTRY; PHOTOCHEMICAL DATA; ORGANIC-COMPOUNDS; VOCS;
D O I
10.1039/d2cp00206j
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
We report a new spectroscopic platform coupled to an atmospheric simulation chamber for the direct determination of chemical rate constants with high accuracy at a second time-scale resolution. These developed analytical instruments consist of an incoherent broadband cavity enhanced absorption spectrometer using a red light emitting diode (LED) emitting at similar to 662 nm (LED-IBBCEAS) associated with a multipass cell direct absorption spectrometer (MPC-DAS) coupled to an external cavity quantum cascade laser (EC-QCL) operating in the mid-infrared region at approximately 8 mu m (EC-QCL-MPC-DAS). Spectrometers were employed to investigate the NO3-initiated oxidation of four selected volatile organic compounds (VOCs) for the determination of the corresponding rate constants with a dynamic range of 5 orders of magnitude (from 10(-11) to 10(-16) cm(3) molecule(-1) s(-1)). Rate constants of (6.5 +/- 0.5) x 10(-15), (7.0 +/- 0.4) x 10(-13), and (5.8 +/- 0.5) x 10(-16) cm(3) molecule(-1) s(-1) for propanal, isoprene and formaldehyde, respectively, were directly determined by fitting the measured concentration-time profiles of NO3 and VOCs (measured using a proton transfer reaction time-of-flight mass spectrometer, PTR-ToF-MS) to chemical models based on the FACSIMILE simulation software (version 4.2.50) at 760 torr and 293 +/- 2 K. The obtained rate constants are in good agreement with the most recent recommendations of the IUPAC (International Union of Pure and Applied Chemistry). In addition, a rate constant of (2.60 +/- 0.30) x 10(-11) cm(3) molecule(-1) s(-1) for the oxidation of 2-methoxyphenol by NO3 radicals was first determined using the absolute kinetic method. Compared to the mostly used indirect relative rate method, the rate constant uncertainty is reduced from similar to 20% to similar to 12%. The results demonstrated the high potential of using modern spectroscopic techniques to directly determine the chemical reaction rate constants.
引用
收藏
页码:7396 / 7404
页数:9
相关论文
共 50 条
  • [31] Validation of in situ Measurements of Atmospheric Nitrous Acid Using Incoherent Broadband Cavity-enhanced Absorption Spectroscopy
    Yoshihiro Nakashima
    Yasuhiro Sadanaga
    Analytical Sciences, 2017, 33 : 519 - 523
  • [32] Sensitive and rapid laser diagnostic for shock tube kinetics studies using cavity-enhanced absorption spectroscopy
    Sun, Kai
    Wang, Shengkai
    Sur, Ritobrata
    Chao, Xing
    Jeffries, Jay B.
    Hanson, Ronald K.
    OPTICS EXPRESS, 2014, 22 (08): : 9291 - 9300
  • [33] Validation of in situ Measurements of Atmospheric Nitrous Acid Using Incoherent Broadband Cavity-enhanced Absorption Spectroscopy
    Nakashima, Yoshihiro
    Sadanaga, Yasuhiro
    ANALYTICAL SCIENCES, 2017, 33 (04) : 519 - 524
  • [34] Absolute frequency stabilization of an extended-cavity diode laser by means of noise-immune cavity-enhanced optical heterodyne molecular spectroscopy
    Dinesan, Hemanth
    Fasci, Eugenio
    Castrillo, Antonio
    Gianfrani, Livio
    OPTICS LETTERS, 2014, 39 (07) : 2198 - 2201
  • [35] Using Hyperheuristics to Improve the Determination of the Kinetic Constants of a Chemical Reaction in Heterogeneous Phase
    Cutillas-Lozano, Jose-Matias
    Gimenez, Domingo
    2014 INTERNATIONAL CONFERENCE ON COMPUTATIONAL SCIENCE, 2014, 29 : 1345 - 1355
  • [36] Determination of the kinetic constants of a chemical reaction in heterogeneous phase using parameterized metaheuristics
    Cutillas-Lozano, Jose-Matias
    Gimenez, Domingo
    2013 INTERNATIONAL CONFERENCE ON COMPUTATIONAL SCIENCE, 2013, 18 : 787 - 796
  • [37] THE COMPLETE DETERMINATION OF KINETIC RATE CONSTANTS FOR COUPLED CHEMICAL-REACTIONS BY MEANS OF RELAXATION SPECTROSCOPY
    JOHNSON, CS
    ROMINE, WO
    CHEMICAL PHYSICS LETTERS, 1980, 71 (01) : 145 - 147
  • [38] APPROXIMATE DETERMINATION OF ABSOLUTE UNIMOLECULAR RATE CONSTANTS USING THE FIELD-IONIZATION KINETIC METHOD
    BRAND, WA
    LEVSEN, K
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1983, 51 (2-3): : 135 - 154
  • [39] Sub-ppb NO2 detection by optical feedback cavity-enhanced absorption spectroscopy with a blue diode laser
    Courtillot, I.
    Morville, J.
    Motto-Ros, V.
    Romanini, D.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2006, 85 (2-3): : 407 - 412
  • [40] Measurement of Trace C2H6 Based on Optical-Feedback Cavity-Enhanced Absorption Spectroscopy
    Wan Fu
    Chen Wei-gen
    Gu Zhao-liang
    Zou Jing-xin
    Du Ling-ling
    Qi Wei
    Zhou Qu
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35 (10) : 2792 - 2796