Investigate the Equivalence of Cone Beam CT (CBCT) versus 4-Dimensinoal (4D) MIP Images for Internal Target Volume (ITV) Definition

被引:0
|
作者
Wang, L.
Fan, J.
Lin, T.
Jin, L.
Feigenberg, S.
Ma, C.
机构
关键词
D O I
10.1118/1.3468297
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
SU-GG-J-73
引用
收藏
页码:3162 / +
页数:2
相关论文
共 50 条
  • [1] INVESTIGATE THE EQUIVALENCE OF CONE BEAM CT (CBCT) VERSUS 4-DIMENSINOAL (4D) MIP IMAGES FOR INTERNAL TARGET VOLUME (ITV) DEFINITION IN LUNG SBRT
    Wang, L.
    Lin, T.
    Fan, J.
    Jin, L.
    Ma, C. M. C.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S528 - S529
  • [2] Is Cone Beam CT (CBCT) Equivalent to 4-Dimensinoal (4D) MIP Images to Account for Target Motion in SBRT Lung Treatment?
    Wang, L.
    Fan, J.
    Lin, T.
    Jin, L.
    Ma, C.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [3] Evaluation of the cone beam CT for internal target volume localization in lung stereotactic radiotherapy in comparison with 4D MIP images
    Wang, Lu
    Chen, Xiaoming
    Lin, Mu-Han
    Xue, Jun
    Lin, Teh
    Fan, Jiajin
    Jin, Lihui
    Ma, Charlie M.
    [J]. MEDICAL PHYSICS, 2013, 40 (11)
  • [4] Determining internal target volume (ITV) for mobile lung tumours: 2-D kilovoltage (kV) fluoroscopy, 3D or 4D cone-beam CT (CBCT)?
    Jain, P.
    Marchant, T.
    Davies, J.
    Duffy, M.
    Watkins, G. R.
    Burt, P. A.
    Faivre-Finn, C.
    Harris, M.
    Stout, R.
    Moore, C.
    Price, P.
    [J]. LUNG CANCER, 2008, 60 : S28 - S28
  • [5] Potentially Underestimating the Internal Target Volume (ITV) in Free-Breathing Cone-Beam CT (CBCT)
    Vergalasova, I.
    Maurer, J.
    Yin, F.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S672 - S672
  • [6] Implementation and evaluation of 4D cone beam CT (CBCT) reconstruction
    Yang, Dong
    Ning, Ruola
    Liu, Shaohua
    Conover, David
    [J]. MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [7] 4D-CT scan and radiotherapy for hepatocellular carcinoma: Role in the definition of internal target volume (ITV)
    De Bari, B.
    Sellal, N.
    Mornex, F.
    [J]. CANCER RADIOTHERAPIE, 2011, 15 (01): : 43 - 48
  • [8] Evaluation of the compatibility and accuracy of lung tumor ITV between 4D-CT and 4D-CBCT MIP images
    Tseng, Y.
    Zhang, M.
    Song, Y.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S951 - S951
  • [9] Target volume definition by 4D CT imaging and temporal projections
    Hristov, D
    Gangadharan, B
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 2112 - 2112
  • [10] Deep learning-based internal gross target volume definition in 4D CT images of lung cancer patients
    Ma, Yuanyuan
    Mao, Jingfang
    Liu, Xinguo
    Dai, Zhongying
    Zhang, Hui
    Zhang, Xinyang
    Li, Qiang
    [J]. MEDICAL PHYSICS, 2023, 50 (04) : 2303 - 2316