Determining internal target volume (ITV) for mobile lung tumours: 2-D kilovoltage (kV) fluoroscopy, 3D or 4D cone-beam CT (CBCT)?

被引:1
|
作者
Jain, P. [2 ]
Marchant, T.
Davies, J. [1 ]
Duffy, M. [1 ]
Watkins, G. R. [2 ]
Burt, P. A.
Faivre-Finn, C.
Harris, M.
Stout, R.
Moore, C.
Price, P. [2 ]
机构
[1] Christie Hosp, Wade Ctr Radiotherapy Res, Manchester, Lancs, England
[2] Univ Manchester, Acad Radiat Oncol, Manchester M13 9PL, Lancs, England
关键词
D O I
10.1016/S0169-5002(08)70088-6
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
87
引用
收藏
页码:S28 / S28
页数:1
相关论文
共 50 条
  • [1] INVESTIGATE THE EQUIVALENCE OF CONE BEAM CT (CBCT) VERSUS 4-DIMENSINOAL (4D) MIP IMAGES FOR INTERNAL TARGET VOLUME (ITV) DEFINITION IN LUNG SBRT
    Wang, L.
    Lin, T.
    Fan, J.
    Jin, L.
    Ma, C. M. C.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S528 - S529
  • [2] Investigate the Equivalence of Cone Beam CT (CBCT) versus 4-Dimensinoal (4D) MIP Images for Internal Target Volume (ITV) Definition
    Wang, L.
    Fan, J.
    Lin, T.
    Jin, L.
    Feigenberg, S.
    Ma, C.
    [J]. MEDICAL PHYSICS, 2010, 37 (06) : 3162 - +
  • [3] 4D cone-beam CT (CBCT) using an on-board imager
    Li, T.
    Xing, L.
    Munro, P.
    Yang, Y.
    Loo, B.
    Koong, A.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2234 - 2234
  • [4] Iterative volume of interest based 4D cone-beam CT
    Martin, Rachael
    Ahmad, Moiz
    Hugo, Geoffrey
    Pan, Tinsu
    [J]. MEDICAL PHYSICS, 2017, 44 (12) : 6515 - 6528
  • [5] Individualizing 4D cone-beam CT (CBCT) acquisition protocol for external beam radiotherapy
    Mao, W.
    Li, T.
    Munro, P.
    Chao, M.
    Xing, L.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S146 - S147
  • [6] 3D and 4D imaging from multi-threaded cone-beam CT scans
    Knaup, Michael
    Kachelriess, Marc
    Kalender, Willi A.
    [J]. 2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1881 - 1885
  • [7] A review on 4D cone-beam CT (4D-CBCT) in radiation therapy: Technical advances and clinical applications
    Zhang, Yawei
    Jiang, Zhuoran
    Zhang, You
    Ren, Lei
    [J]. MEDICAL PHYSICS, 2024, 51 (08) : 5164 - 5180
  • [8] Accuracy Verification of 4D Cone Beam CT (CBCT)-Based Lung Tumor Registration by Way of In-Treatment 4D CBCT Analysis
    Nakagawa, K.
    Haga, A.
    Takahashi, W.
    Yamashita, H.
    Imae, T.
    Kida, S.
    Masutani, Y.
    Kotoku, J.
    Sakumi, A.
    Ohtomo, K.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S752 - S752
  • [9] Evaluation of 4D CT to 4D Cone-Beam CT Deformable Image Registration for Lung Cancer Adaptive Radiation Therapy
    Balik, S.
    Hugo, G.
    Weiss, E.
    Jan, N.
    Roman, N.
    Sleeman, W.
    Fatyga, M.
    Christensen, G.
    Murphy, M.
    Lu, J.
    Keall, P.
    Williamson, J.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3875 - 3875
  • [10] Evaluation of the cone beam CT for internal target volume localization in lung stereotactic radiotherapy in comparison with 4D MIP images
    Wang, Lu
    Chen, Xiaoming
    Lin, Mu-Han
    Xue, Jun
    Lin, Teh
    Fan, Jiajin
    Jin, Lihui
    Ma, Charlie M.
    [J]. MEDICAL PHYSICS, 2013, 40 (11)