Implementation and evaluation of 4D cone beam CT (CBCT) reconstruction

被引:0
|
作者
Yang, Dong [1 ]
Ning, Ruola [1 ]
Liu, Shaohua [2 ]
Conover, David [2 ]
机构
[1] Univ Rochester, Dept Elect Commun Engn & Radiol, 601 Elmwood Ave, Rochester, NY 14627 USA
[2] Univ Rochester, Ctr Med, Dept Radiol, 601 Elmwood Ave, Rochester, NY 14642 USA
关键词
half-scan; cone-beam CT; flat panel detector; functional study;
D O I
10.1117/12.710222
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Tumor angiogenesis is the process by which new blood vessels are formed from the existing vessels in a tumor to promote tumor growth. Tumor angiogenesis has important implications in the diagnosis and treatment of various solid tumors. Flat panel detector based cone beam CT opens up a new way for detection of tumors, and tumor angiogenesis associated with functional CBCT has the potential to provide more information than traditional functional CT due to more overall coverage during the same scanning period and the reconstruction being isotropic resulting in a more accurate 3D volume intensity measurement. A functional study was conducted by using CBCT to determine the degree of the enhancement within the tumor after injecting the contrast agent intravenously. For typical doses of contrast material, the amount of enhancement is proportional to the concentration of this material within the region of interest. A series of images obtained at one location over time allows generation of time-attenuation data from which a number of semi-quantitative parameters, such as enhancement rate, can be determined. Computer simulations prove the superiority of half scan over full scan in terms of more accurately delineating the time-intensity curve, and all the simulation parameter settings are based on the actual CBCT prototype. An experiment study was conducted on our prototype CBCT system, and a full and half scan scheme is used to determine the time-intensity curve within the ROI of the mouse. The CBCT has an x-ray tube, a gantry with slip ring technology, and a 40x30 cm Varian Paxscan 4030CB real time FPD.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] 4D cone-beam CT (CBCT) using an on-board imager
    Li, T.
    Xing, L.
    Munro, P.
    Yang, Y.
    Loo, B.
    Koong, A.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2234 - 2234
  • [2] Evaluation of a 4D Cone-Beam CT Reconstruction Approach Using an Anthropomorphic Phantom
    Yaniv, Ziv
    Boese, Ian
    Sarmiento, Marily
    Cleary, Kevin
    [J]. INFORMATION PROCESSING IN COMPUTER-ASSISTED INTERVENTIONS, 2010, 6135 : 147 - +
  • [3] Evaluation of a 4D Cone-Beam CT Reconstruction Approach using a Simulation Framework
    Hartl, Alexander
    Yaniv, Ziv
    [J]. 2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 5729 - 5732
  • [4] Individualizing 4D cone-beam CT (CBCT) acquisition protocol for external beam radiotherapy
    Mao, W.
    Li, T.
    Munro, P.
    Chao, M.
    Xing, L.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S146 - S147
  • [5] Accuracy Verification of 4D Cone Beam CT (CBCT)-Based Lung Tumor Registration by Way of In-Treatment 4D CBCT Analysis
    Nakagawa, K.
    Haga, A.
    Takahashi, W.
    Yamashita, H.
    Imae, T.
    Kida, S.
    Masutani, Y.
    Kotoku, J.
    Sakumi, A.
    Ohtomo, K.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S752 - S752
  • [6] Adaptive 4D cone beam CT
    Lu, J.
    Zhu, R.
    Munro, P.
    Jeung, A.
    Mostafave, H.
    Chi, P.
    Balter, P.
    Guerrero, T.
    Mohan, R.
    Pan, T.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S609 - S609
  • [7] Directional Interpolation for Motion Weighted 4D Cone-Beam CT Reconstruction
    Zhang, Hua
    Sonke, Jan-Jakob
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2012, PT I, 2012, 7510 : 181 - 188
  • [8] Simultaneous motion estimation and image reconstruction (SMEIR) for 4D cone-beam CT
    Wang, Jing
    Gu, Xuejun
    [J]. MEDICAL PHYSICS, 2013, 40 (10)
  • [9] Simultaneous Motion Estimation and Image Reconstruction (SMEIR) for 4D Cone-beam CT
    Wang, Jing
    Gu, Xuejun
    [J]. MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [10] A hybrid reconstruction algorithm for fast and accurate 4D cone-beam CT imaginga)
    Yan, Hao
    Zhen, Xin
    Folkerts, Michael
    Li, Yongbao
    Pan, Tinsu
    Cervino, Laura
    Jiang, Steve B.
    Jia, Xun
    [J]. MEDICAL PHYSICS, 2014, 41 (07)