Design and Implementation of a Dual-Region Self-Referencing Fiber-Optic Surface Plasmon Resonance Biosensor

被引:13
|
作者
Bello, Valentina [1 ,2 ]
Vandezande, Wouter [3 ]
Daems, Devin [2 ]
Lammertyn, Jeroen [2 ]
机构
[1] Univ Pavia, Dept Elect Comp & Biomed Engn, Dept Biosyst, I-27100 Pavia, Italy
[2] Katholieke Univ Leuven, Fac Biosci Engn, Dept Biosyst, MeBioS Biosensor Grp, B-3001 Leuven, Belgium
[3] Katholieke Univ Leuven, Ctr Membrane Separat Adsorpt Catalysis & Spect Sus, Dept Microbial & Mol Syst, B-3001 Leuven, Belgium
基金
欧盟地平线“2020”;
关键词
surface plasmon resonance; fiber-optic biosensor; dual-region biosensor; aptamer-based bioassay; high-resolution melting assay; REFRACTIVE-INDEX; SPR SENSOR; SENSITIVITY; EXCITATION; SILVER;
D O I
10.1021/acssensors.2c01362
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The need for self-referencing is extremely important in the field of biosensing. In this manuscript, we report on the study, design, and validation of a dual-region self-referencing fiber-optic surface plasmon resonance biosensor. One region is intended to measure and monitor the binding events of the biological sample under test, while the other one is designed to be used as a reference channel to compensate for external factors, such as bulk refractive index modifications and temperature oscillations, that can negatively affect the biomolecular interaction measurement. Two different configurations for the biosensor probe are presented and investigated here, both theoretically and experimentally. First, the theoretical performance of the proposed biosensor probes, in terms of surface plasmon resonance wavelength shift, was simulated using a numerical model. Afterward, they were experimentally validated in sucrose-water solutions and showed a response to refractive index and temperature changes with sensitivities up to 2000 nm/RIU and 1.559 nm/degrees C, respectively. Finally, an aptamer-based bioassay and a high-resolution melting assay were successfully implemented on the two proposed configurations, demonstrating the feasibility of analyzing the binding events and measuring other external signal modifications simultaneously using the same biosensor probe.
引用
收藏
页码:3360 / 3368
页数:9
相关论文
共 50 条
  • [31] Using monoclonal antibody to determine lead ions with a localized surface plasmon resonance fiber-optic biosensor
    Lin, Tsao-Jen
    Chung, Mon-Fu
    [J]. SENSORS, 2008, 8 (01) : 582 - 593
  • [32] A self-referencing fiber-optic sensor for macro-bending detection immune to temperature and strain perturbations
    Jeong, Y
    Baek, S
    Lee, B
    [J]. 14TH INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS, 2000, 4185 : 700 - 703
  • [33] Novel dual-channel fiber-optic surface plasmon resonance sensors for biological monitoring
    Peng, Wei
    Kim, Yoon-Chang
    Banerji, Soame
    Booksh, Karl S.
    [J]. SMART STRUCTURES AND MATERIALS 2006: SMART SENSOR MONITORING SYSTEMS AND APPLICATIONS, 2006, 6167
  • [34] Investigation of dual-channel fiber-optic surface plasmon resonance sensing for biological applications
    Peng, W
    Banerji, S
    Kim, YC
    Booksh, KS
    [J]. OPTICS LETTERS, 2005, 30 (22) : 2988 - 2990
  • [35] Fiber Surface Modification Technology for Fiber-Optic Localized Surface Plasmon Resonance Biosensors
    Zhang, Qiang
    Xue, Chenyang
    Yuan, Yanling
    Lee, Junyang
    Sun, Dong
    Xiong, Jijun
    [J]. SENSORS, 2012, 12 (03) : 2729 - 2741
  • [36] Localized surface plasmon coupled fluorescence fiber-optic biosensor with gold nanoparticles
    Hsieh, Bao-Yu
    Chang, Ying-Feng
    Ng, Ming-Yaw
    Liu, Wei-Chih
    Lin, Chao-Hsiung
    Wu, Hsieh-Ting
    Chou, Chien
    [J]. ANALYTICAL CHEMISTRY, 2007, 79 (09) : 3487 - 3493
  • [37] Surface functionalization for self-referencing surface plasmon resonance (SPR) biosensors by multi-step self-assembly
    Boozer, C
    Yu, QM
    Chen, SF
    Lee, CY
    Homola, J
    Yee, SS
    Jiang, SY
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2003, 90 (1-3) : 22 - 30
  • [38] Fiber-Optic Surface Plasmon Resonance Sensors and Biochemical Applications: A Review
    Liu, Yun
    Peng, Wei
    [J]. JOURNAL OF LIGHTWAVE TECHNOLOGY, 2021, 39 (12) : 3781 - 3791
  • [39] Measurement of glucose concentration by fiber-optic surface plasmon resonance sensor
    Li, Dachao
    Zhu, Rui
    Wu, Peng
    Wu, Jianwei
    Xu, Kexin
    [J]. OPTICAL FIBERS AND SENSORS FOR MEDICAL DIAGNOSTICS AND TREATMENT APPLICATIONS XIII, 2013, 8576
  • [40] Surface plasmon resonance based fiber-optic sensor for the detection of pesticide
    Rajan
    Chand, Subhash
    Gupta, B. D.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2007, 123 (02) : 661 - 666