Hourly dynamic simulation of solar ejector cooling system using TRNSYS for Jordanian climate

被引:79
|
作者
Tashtoush, Bourhan [1 ]
Alshare, Aiman [2 ]
Al-Rifai, Saja [1 ]
机构
[1] JUST, Dept Mech Engn, Irbid, Jordan
[2] German Jordanian Univ, Mech & Maintenance Engn Dept, Sakhr Al Ahmasi, Jordan
关键词
Solar cooling air-conditioning; Ejector; Evacuated tube solar collectors; Flat plate collector; TRNSYS; EES; VARIABLE GEOMETRY EJECTORS; REFRIGERATION SYSTEM; PERFORMANCE; DESIGN; COLLECTORS; CYCLES; ENERGY; R600A;
D O I
10.1016/j.enconman.2015.05.010
中图分类号
O414.1 [热力学];
学科分类号
摘要
This work describes a simulation program developed on the TRNSYS-EES softwares. This program is used to design the solar collector subsystem components and to evaluate the performance of the solar ejector cooling system with R134a as a refrigerant. In addition dynamic hourly simulation of 7 kW solar ejector cooling system (SECS) constant pressure mixing components, using TRNSYS software is carried out. The performance of solar collector and the overall system performance are investigated and the ejector sub-system is modeled with EES software. The solar collector type, area, storage tank size, and the flow rate through the cycle are optimized. Solar collector type and area are selected based on the maximum energy gain, where the maximum energy gain is a measure of the collector performance. The system performance is computed in the form of desired outlet temperature to run 7 kW cooling cycle. The effect of tilt angle on the solar system performance is investigated and the optimum tilt angle for the best performance of the system is determined. Selection of the best refrigerant to meet the cooling requirement with the maximum COP is studied. In addition, the time fraction of the storage tank outlet temperature for different collector areas, at a mass flow rate of 50 kg/h m(2) is investigated. It is found that evacuated tube type has better performance than the flat plate type, where each collector is anchored at its optimal tilt angle of 28 degrees. Furthermore, the energy required of the 7 kW-cooling-system is adequately met with the selection of an evacuated-tube solar collector system with an area of 60-70 m(2). The solar fraction is in the range of 0.52-0.542 and the corresponding time fraction is 5.04 h/days. Hourly and monthly simulation of SECS, which is supplemented with 2 m(3) storage tank size and operated at a flow rate of 50 kg/h per square meter of collector area is carried out. Under peak solar radiation and highest ambient temperature, the overall system efficiency has a minimum value of 0.32, whereas the COPejec of the ejector cooling cycle for this model is in the range of 0.52-0.547, the solar collector efficiency is between 0.52 and 0.92, and the overall COPo is in the range of 0.32-0.47. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:288 / 299
页数:12
相关论文
共 50 条
  • [41] Dynamic simulation of a trigeneration system using an absorption cooling system and building integrated photovoltaic thermal solar collectors
    Jalalizadeh, Mohammad
    Fayaz, Rima
    Delfani, Shahram
    Mosleh, Hassan Jafari
    Karami, Maryam
    JOURNAL OF BUILDING ENGINEERING, 2021, 43
  • [42] Numerical simulation of a cooling tower coupled with heat pump system associated with single house using TRNSYS
    Chargui, R.
    Sammouda, H.
    Farhat, A.
    ENERGY CONVERSION AND MANAGEMENT, 2013, 75 : 105 - 117
  • [43] Theoretical and experimental study on solar ejector cooling system using R236fa
    Zhang, B.
    Lv, J. S.
    Zuo, J. X.
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2014, 9 (04) : 245 - 249
  • [44] SOLAR THERMAL SYSTEM SIMULATION OF PEANUT DRYING DEVICE BASED ON TRNSYS
    Wang, Chao
    Zhang, GuoLiang
    Yang, Liu
    Zhang, ChuanYang
    INMATEH-AGRICULTURAL ENGINEERING, 2018, 54 (01): : 55 - 62
  • [45] Analysis of a solar-assisted ejector cooling system for air conditioning
    Varga, Szabolcs
    Oliveira, Armando C.
    Diaconu, Bogdan
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2009, 4 (01) : 2 - 8
  • [46] On the validity of a design method for a solar-assisted ejector cooling system
    Colle, S.
    Pereira, G. S.
    Vidal Gutierrez, H. R.
    Escobar Moragas, R.
    SOLAR ENERGY, 2009, 83 (02) : 139 - 149
  • [47] Ejector Configuration for Designing a Simple and High Performance Solar Cooling System
    Saito, Yusuke
    Ito, Tatsuya
    Matsuo, Akiko
    Sato, Haruki
    2013 ISES SOLAR WORLD CONGRESS, 2014, 57 : 2564 - 2571
  • [48] Performance of a solar ejector cooling-system in the southern region of Turkey
    Ersoy, H. Kursad
    Yalcin, Sakir
    Yapici, Rafet
    Ozgoren, Muammer
    APPLIED ENERGY, 2007, 84 (09) : 971 - 983
  • [49] On the validaty of a design method to estimate the solar fraction for an ejector cooling system
    Colle, Sergio
    Pereira, Guilherme dos Santos
    Gutierrez, Humberto Ricardo Vidal
    PROCEEDINGS OF ISES SOLAR WORLD CONGRESS 2007: SOLAR ENERGY AND HUMAN SETTLEMENT, VOLS I-V, 2007, : 848 - 852
  • [50] Combined cooling and power system with solar-driven ejector refrigeration
    Xu Y.
    Wang H.
    Ge Z.
    Wang J.
    Xia Y.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2022, 43 (04): : 249 - 255