Hourly dynamic simulation of solar ejector cooling system using TRNSYS for Jordanian climate

被引:79
|
作者
Tashtoush, Bourhan [1 ]
Alshare, Aiman [2 ]
Al-Rifai, Saja [1 ]
机构
[1] JUST, Dept Mech Engn, Irbid, Jordan
[2] German Jordanian Univ, Mech & Maintenance Engn Dept, Sakhr Al Ahmasi, Jordan
关键词
Solar cooling air-conditioning; Ejector; Evacuated tube solar collectors; Flat plate collector; TRNSYS; EES; VARIABLE GEOMETRY EJECTORS; REFRIGERATION SYSTEM; PERFORMANCE; DESIGN; COLLECTORS; CYCLES; ENERGY; R600A;
D O I
10.1016/j.enconman.2015.05.010
中图分类号
O414.1 [热力学];
学科分类号
摘要
This work describes a simulation program developed on the TRNSYS-EES softwares. This program is used to design the solar collector subsystem components and to evaluate the performance of the solar ejector cooling system with R134a as a refrigerant. In addition dynamic hourly simulation of 7 kW solar ejector cooling system (SECS) constant pressure mixing components, using TRNSYS software is carried out. The performance of solar collector and the overall system performance are investigated and the ejector sub-system is modeled with EES software. The solar collector type, area, storage tank size, and the flow rate through the cycle are optimized. Solar collector type and area are selected based on the maximum energy gain, where the maximum energy gain is a measure of the collector performance. The system performance is computed in the form of desired outlet temperature to run 7 kW cooling cycle. The effect of tilt angle on the solar system performance is investigated and the optimum tilt angle for the best performance of the system is determined. Selection of the best refrigerant to meet the cooling requirement with the maximum COP is studied. In addition, the time fraction of the storage tank outlet temperature for different collector areas, at a mass flow rate of 50 kg/h m(2) is investigated. It is found that evacuated tube type has better performance than the flat plate type, where each collector is anchored at its optimal tilt angle of 28 degrees. Furthermore, the energy required of the 7 kW-cooling-system is adequately met with the selection of an evacuated-tube solar collector system with an area of 60-70 m(2). The solar fraction is in the range of 0.52-0.542 and the corresponding time fraction is 5.04 h/days. Hourly and monthly simulation of SECS, which is supplemented with 2 m(3) storage tank size and operated at a flow rate of 50 kg/h per square meter of collector area is carried out. Under peak solar radiation and highest ambient temperature, the overall system efficiency has a minimum value of 0.32, whereas the COPejec of the ejector cooling cycle for this model is in the range of 0.52-0.547, the solar collector efficiency is between 0.52 and 0.92, and the overall COPo is in the range of 0.32-0.47. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:288 / 299
页数:12
相关论文
共 50 条
  • [31] Solar-driven ejector-absorption cooling system
    Sözen, A
    Özalp, M
    APPLIED ENERGY, 2005, 80 (01) : 97 - 113
  • [32] Application research of solar ejector cooling system in zhengzhou region
    Zheng, H. F.
    Li, A. G.
    Fan, X. W.
    Wang, F. K.
    Zhang, X. P.
    CRYOGENICS AND REFRIGERATION, PROCEEDINGS, 2008, : 565 - 569
  • [33] A novel hybrid solar ejector cooling system with thermoelectric generators
    Al-Nimr, Moh'd Ahmad
    Tashtoush, Bourhan
    Hasan, Alabas
    ENERGY, 2020, 198
  • [34] A TRNSYS Dynamic Simulation Model for Photovoltaic System Powering a Reverse Osmosis Desalination Unit with Solar Energy
    Chaker, Rym
    Dhaouadi, Hatem
    Mhiri, Hatem
    Bournot, Philippe
    INTERNATIONAL JOURNAL OF CHEMICAL REACTOR ENGINEERING, 2010, 8
  • [35] Performance analysis of a solar cooling system using self tuning fuzzy-PID control with TRNSYS
    Visek, Emilia
    Mazzrella, Livio
    Motta, Mario
    2013 ISES SOLAR WORLD CONGRESS, 2014, 57 : 2609 - 2618
  • [36] Modelling of a solar desiccant cooling system using a TRNSYS-MATLAB co-simulator: A review
    Sudhakar, K.
    Jenkins, Matthew S.
    Mangal, Shivy
    Priya, S. Shanmuga
    JOURNAL OF BUILDING ENGINEERING, 2019, 24
  • [37] A TRNSYS dynamic simulation model for photovoltaic system powering a reverse osmosis desalination unit with solar energy
    Chaker R.
    Dhaouadi H.
    Mhiri H.
    Bournot P.
    International Journal of Chemical Reactor Engineering, 2010, 8
  • [38] Design of Solar Heating and Cooling System in Cold Areas of China Based on TRNSYS
    Liang, Ruobing
    Zhang, Jili
    Ma, Liangdong
    Zhao, Liang
    Shen, Shengqiang
    SUSTAINABLE CITIES DEVELOPMENT AND ENVIRONMENT, PTS 1-3, 2012, 209-211 : 1778 - 1782
  • [39] Solar thermal power plants simulation using the TRNSYS software
    Popel, O.S.
    Frid, S.E.
    Shpilrain, E.E.
    Journal De Physique. IV : JP, 1999, 9 (03): : 3 - 599
  • [40] Solar thermal power plants simulation using the TRNSYS software
    Popel, OS
    Frid, SE
    Shpilrain, EE
    JOURNAL DE PHYSIQUE IV, 1999, 9 (P3): : 599 - 604