Assessment of Solid Insulation by Analyzing Oil in Service Transformers and Laboratory Ageing Studies

被引:0
|
作者
Maiti, Prabhat Kumar [1 ]
机构
[1] CPRI, Reg Testing Lab, Kolkata, India
关键词
ageing; solid insulation; furan; DGA; FURANIC COMPOUNDS; POLYMERIZATION; TEMPERATURES; CELLULOSE; PAPER;
D O I
10.1109/CATCON56237.2022.10077656
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
Transformers are the most critical and costliest equipment in the power grid system. Therefore, fir a reliable power supply, it is crucial to ensure the power transformer is operating at its best level. The ageing of oil -tilled power transformers causes several flaws in the insulating materials. The remaining life of a transformer is assessed by the ageing status of its liquid and solid insulation. The quality of liquid insulation is maintained by processes like filtration, reclamation, replacement, etc., depending on the level of degradation of the oil, whereas severe deterioration of solid insulation necessitates more expensive activities such as rewinding or replacement of the transformer. Therefore, effective diagnostic methods are essential to analyze the insulation status of the transformer. Presently, there are various techniques in practice for the assessment of insulation status. Among the methods, degree of polymerization (DP) is the most significant one. Nevertheless, obtaining a representative paper sample from an operational transformer is difficult. In this paper, an attempt is made to assess the insulation status of a transfimmer through the estimating oil samples. Oil samples of transformers in service are brought to the laboratory and investigated for various electrical and physicochemical properties, including furan content, CO2/CO ratio, and alcohol content. The relationship between furan content and various oil parameters is analyzed. The study is further extended to the assessment of laboratory aged test samples of oil/paper/copper systems, aged at 130 degrees C for up to 14 days. In field samples, a correlation between furan content, CO2/CO ratio, and oil property is obtained where oil-paper equilibrium is undisturbed by treatment of oil. In the case of laboratory aged samples, the concentration of furan is thund to increase with an increase in the duration of thermal exposure, varying with oil property. This investigation demonstrates that accurate and systematic condition monitoring of oil can be considered as an alternate to DP measurement.
引用
收藏
页码:288 / 292
页数:5
相关论文
共 50 条
  • [41] Method for Rating and Analyzing the Combined Effects of Moisture and Temperature on the Oil-Paper Insulation System of Power Transformers by Means of Load Variations
    de Carvalho Sousa, Felipe Resende
    de Jesus Ribeiro, Cacilda
    Pereira Marques, Andre
    da Cunha Brito, Leonardo
    [J]. JOURNAL OF CONTROL AUTOMATION AND ELECTRICAL SYSTEMS, 2020, 31 (05) : 1309 - 1321
  • [42] Experimental dataset on the tensile and compressive mechanical properties of plain Kraft and crepe papers used as insulation in power transformers after ageing in mineral oil
    Oria, Carmela
    Carrascal, Isidro
    Ferreno, Diego
    Fernandez, Inmaculada
    Ortiz, Alfredo
    [J]. DATA IN BRIEF, 2021, 36
  • [43] Frequency domain dielectric characteristic parameters for quantitative assessment of moisture content of oil-paper insulation in power transformers
    Liao, Ruijin
    Liu, Jiefeng
    Lü, Yandong
    Yang, Lijun
    Gao, Jun
    [J]. Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2015, 30 (01): : 204 - 211
  • [45] Ageing condition assessment of oil-paper insulation using near infrared spectroscopy detection and analytical technique
    Tang, Feng
    Zhang, Yin
    Yuan, Bin
    Li, Yuan
    Zhang, Wen-Bo
    Zhang, Guan-Jun
    [J]. JOURNAL OF ENGINEERING-JOE, 2019, (16): : 3026 - 3029
  • [46] Thermal ageing study on palm oil methyl ester-impregnated thermally upgraded kraft paper insulation for reliable application in HVDC converter transformers
    Thavasilingam, Sudhakar
    Venugopal, Nisha Patingareveettil
    Paramasivan, Muthukumar
    Rathinam, Muniraj
    Manikandan, Shanmugam
    Thankaswamy, Jarin
    [J]. ELECTRICAL ENGINEERING, 2024,
  • [47] Assessment of insulation condition of 130 kV oil-paper current transformers using return voltage measurements and an expert system
    Krivda, A
    Neimanis, R
    Gubanski, SM
    [J]. IEEE 1997 ANNUAL REPORT - CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS I AND II, 1997, : 210 - 213
  • [48] Feedforward Artificial Neural Network (FFANN) Application in Solid Insulation Evaluation Methods for the Prediction of Loss of Life in Oil-Submerged Transformers
    Thango, Bonginkosi A.
    [J]. ENERGIES, 2022, 15 (22)
  • [49] Determination of copper in liquid and solid insulation for large electrical equipment by ICP-OES. Application to copper contamination assessment in power transformers
    Bruzzoniti, Maria Concetta
    De Carlo, Rosa Maria
    Sarzanini, Corrado
    Maina, Riccardo
    Tumiatti, Vander
    [J]. TALANTA, 2012, 99 : 703 - 711
  • [50] Method for quantitative assessment of transformer oil-paper insulation non-uniform ageing parameters based on frequency domain dielectric response
    Zhang, Mingze
    Li, Lu
    Liu, Heqian
    Jia, Haifeng
    Liu, Ji
    Meng, Fanhao
    [J]. IET SCIENCE MEASUREMENT & TECHNOLOGY, 2022, 16 (02) : 118 - 129