Investigation into Cervical Spine Biomechanics Following Single, Multilevel and Hybrid Disc Replacement Surgery with Dynamic Cervical Implant and Fusion: A Finite Element Study

被引:5
|
作者
Mumtaz, Muzammil [1 ,2 ,3 ,4 ]
Zafarparandeh, Iman [5 ]
Erbulut, Deniz Ufuk [6 ]
机构
[1] Univ Toledo, Engn Ctr Orthopaed Res Excellence ECORE, Coll Engn, Dept Bioengn, Toledo, OH 43606 USA
[2] Univ Toledo, Engn Ctr Orthopaed Res Excellence ECORE, Coll Med, Dept Bioengn, Toledo, OH 43606 USA
[3] Univ Toledo, Engn Ctr Orthopaed Res Excellence ECORE, Coll Engn, Dept Orthopaed Surg, Toledo, OH 43606 USA
[4] Univ Toledo, Engn Ctr Orthopaed Res Excellence ECORE, Coll Med, Dept Orthopaed Surg, Toledo, OH 43606 USA
[5] Medipol Univ, Dept Biomed Engn, TR-34810 Istanbul, Turkey
[6] Metro North Hosp & Hlth Serv, Herston Biofabricat Inst, Brisbane, Qld 4029, Australia
来源
BIOENGINEERING-BASEL | 2022年 / 9卷 / 01期
关键词
cervical spine; finite element; dynamic cervical implant; multilevel fusion; hybrid surgery; disc replacement;
D O I
10.3390/bioengineering9010016
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Cervical fusion has been a standard procedure for treating abnormalities associated with the cervical spine. However, the reliability of anterior cervical discectomy and fusion (ACDF) has become arguable due to its adverse effects on the biomechanics of adjacent segments. One of the drawbacks associated with ACDF is adjacent segment degeneration (ASD), which has served as the base for the development of dynamic stabilization systems (DSS) and total disc replacement (TDR) devices for cervical spine. However, the hybrid surgical technique has also gained popularity recently, but its effect on the biomechanics of cervical spine is not well researched. Thus, the objective of this FE study was to draw a comparison among single-level, bi-level, and hybrid surgery with dynamic cervical implants (DCIs) with traditional fusion. Reductions in the range of motion (ROM) for all the implanted models were observed for all the motions except extension, compared to for the intact model. The maximum increase in the ROM of 42% was observed at segments C5-C6 in the hybrid DCI model. The maximum increase in the adjacent segment's ROM of 8.7% was observed in the multilevel fusion model. The maximum von Mises stress in the implant was highest for the multilevel DCI model. Our study also showed that the shape of the DCI permitted flexion/extension relatively more compared to lateral bending and axial rotation.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Biomechanics of coupled motion in the cervical spine during simulated whiplash in patients with pre-existing cervical or lumbar spinal fusion A FINITE ELEMENT STUDY
    Huang, H.
    Nightingale, R. W.
    Dang, A. B. C.
    BONE & JOINT RESEARCH, 2018, 7 (01): : 28 - 35
  • [42] The Evidence for the Use of Osteobiologics in Hybrid Constructs (Anterior Cervical Discectomy and Fusion and Total Disc Replacement) in Multilevel Cervical Degenerative Disc Disease: A Systematic Review
    Hoelen, Thomay-Claire A.
    Willems, Paul C.
    Loenen, Arjan
    Meisel, Hans Joerg
    Wang, Jeffrey C.
    Jain, Amit
    Buser, Zorica
    Arts, Jacobus J.
    GLOBAL SPINE JOURNAL, 2024, 14 (2_SUPPL) : 120S - 128S
  • [43] Influence of assigned material combination in a simulated total cervical disc replacement design on kinematics of a model of the full cervical spine: A finite element analysis study
    Qi, Yuxin
    Lewis, Gladius
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2016, 27 (06) : 633 - 646
  • [44] Comparative analysis of the biomechanics of anterior cervical discectomy and fusion with multiple segmental plates fixation versus single multilevel plate fixation: a finite element study
    Huang, Weibo
    Tian, Ye
    Wang, Hongli
    Zou, Fei
    Ma, Xiaosheng
    Jiang, Jianyuan
    Li, Ruoyu
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [45] Comparative analysis of the biomechanics of anterior cervical discectomy and fusion with multiple segmental plates fixation versus single multilevel plate fixation: a finite element study
    Weibo Huang
    Ye Tian
    Hongli Wang
    Fei Zou
    Xiaosheng Ma
    Jianyuan Jiang
    Ruoyu Li
    BMC Musculoskeletal Disorders, 23
  • [46] External and internal responses of cervical disc arthroplasty and anterior cervical discectomy and fusion: A finite element modeling study
    Purushothaman, Yuvaraj
    Yoganandan, Narayan
    Jebaseelan, Davidson
    Choi, Hoon
    Baisden, Jamie
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2020, 106
  • [47] The safety and efficacy of hybrid surgery for multilevel cervical degenerative disc disease versus anterior cervical discectomy and fusion or cervical disc arthroplasty: a systematic review and meta-analysis
    Marcus A. Hollyer
    Emma C. Gill
    Salma Ayis
    Andreas K. Demetriades
    Acta Neurochirurgica, 2020, 162 : 289 - 303
  • [48] The safety and efficacy of hybrid surgery for multilevel cervical degenerative disc disease versus anterior cervical discectomy and fusion or cervical disc arthroplasty: a systematic review and meta-analysis
    Hollyer, Marcus A.
    Gill, Emma C.
    Ayis, Salma
    Demetriades, Andreas K.
    ACTA NEUROCHIRURGICA, 2020, 162 (02) : 289 - 303
  • [49] Comparison of sagittal parameters for anterior cervical discectomy and fusion, hybrid surgery, and total disc replacement for three levels of cervical spondylosis
    Hung, Che-Wei
    Wu, Ming-Fang
    Yu, Gwo-Fane
    Ko, Chin-Chu
    Kao, Cheng-Hsing
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2018, 168 : 140 - 146
  • [50] RETRACTED: Hybrid Surgery Versus Anterior Cervical Discectomy and Fusion in Multilevel Cervical Disc Diseases: A Meta-Analysis (Retracted Article)
    Zhang, Jianfeng
    Meng, Fanxin
    Ding, Yan
    Li, Jie
    Han, Jian
    Zhang, Xintao
    Dong, Wei
    MEDICINE, 2016, 95 (21)