Investigation into Cervical Spine Biomechanics Following Single, Multilevel and Hybrid Disc Replacement Surgery with Dynamic Cervical Implant and Fusion: A Finite Element Study

被引:5
|
作者
Mumtaz, Muzammil [1 ,2 ,3 ,4 ]
Zafarparandeh, Iman [5 ]
Erbulut, Deniz Ufuk [6 ]
机构
[1] Univ Toledo, Engn Ctr Orthopaed Res Excellence ECORE, Coll Engn, Dept Bioengn, Toledo, OH 43606 USA
[2] Univ Toledo, Engn Ctr Orthopaed Res Excellence ECORE, Coll Med, Dept Bioengn, Toledo, OH 43606 USA
[3] Univ Toledo, Engn Ctr Orthopaed Res Excellence ECORE, Coll Engn, Dept Orthopaed Surg, Toledo, OH 43606 USA
[4] Univ Toledo, Engn Ctr Orthopaed Res Excellence ECORE, Coll Med, Dept Orthopaed Surg, Toledo, OH 43606 USA
[5] Medipol Univ, Dept Biomed Engn, TR-34810 Istanbul, Turkey
[6] Metro North Hosp & Hlth Serv, Herston Biofabricat Inst, Brisbane, Qld 4029, Australia
来源
BIOENGINEERING-BASEL | 2022年 / 9卷 / 01期
关键词
cervical spine; finite element; dynamic cervical implant; multilevel fusion; hybrid surgery; disc replacement;
D O I
10.3390/bioengineering9010016
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Cervical fusion has been a standard procedure for treating abnormalities associated with the cervical spine. However, the reliability of anterior cervical discectomy and fusion (ACDF) has become arguable due to its adverse effects on the biomechanics of adjacent segments. One of the drawbacks associated with ACDF is adjacent segment degeneration (ASD), which has served as the base for the development of dynamic stabilization systems (DSS) and total disc replacement (TDR) devices for cervical spine. However, the hybrid surgical technique has also gained popularity recently, but its effect on the biomechanics of cervical spine is not well researched. Thus, the objective of this FE study was to draw a comparison among single-level, bi-level, and hybrid surgery with dynamic cervical implants (DCIs) with traditional fusion. Reductions in the range of motion (ROM) for all the implanted models were observed for all the motions except extension, compared to for the intact model. The maximum increase in the ROM of 42% was observed at segments C5-C6 in the hybrid DCI model. The maximum increase in the adjacent segment's ROM of 8.7% was observed in the multilevel fusion model. The maximum von Mises stress in the implant was highest for the multilevel DCI model. Our study also showed that the shape of the DCI permitted flexion/extension relatively more compared to lateral bending and axial rotation.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Surgical strategy used in multilevel cervical disc replacement and cervical hybrid surgery: Four case reports
    Wang, Xiao-Fei
    Meng, Yang
    Liu, Hao
    Hong, Ying
    Wang, Bei-Yu
    WORLD JOURNAL OF CLINICAL CASES, 2020, 8 (17) : 3890 - 3902
  • [22] Surgical strategy used in multilevel cervical disc replacement and cervical hybrid surgery: Four case reports
    Xiao-Fei Wang
    Yang Meng
    Hao Liu
    Ying Hong
    Bei-Yu Wang
    World Journal of Clinical Cases, 2020, (17) : 3890 - 3902
  • [23] Biomechanical evaluation of a dynamic fusion cage design for cervical spine: A finite element study
    Liu, Jung-Tung
    Chen, Wen-Chuan
    Wei, Hung-Wen
    ADVANCES IN MECHANICAL ENGINEERING, 2017, 9 (05)
  • [24] EFFECTS OF CERVICAL DISC REPLACEMENT AND ANTERIOR FUSION FOR DIFFERENT BONE CONDITIONS: A FINITE ELEMENT STUDY
    Biswas, Jayanta Kumar
    Roy, Sandipan
    Pradhan, Rururaj
    Rana, Masud
    Majumdar, Sourav
    INTERNATIONAL JOURNAL FOR MULTISCALE COMPUTATIONAL ENGINEERING, 2019, 17 (04) : 411 - 427
  • [25] Biomechanics following skip-level cervical disc arthroplasty versus skip-level cervical discectomy and fusion: a finite element-based study
    Ting-kui Wu
    Yang Meng
    Bei-yu Wang
    Xin Rong
    Ying Hong
    Chen Ding
    Hua Chen
    Hao Liu
    BMC Musculoskeletal Disorders, 20
  • [26] Biomechanics following skip-level cervical disc arthroplasty versus skip-level cervical discectomy and fusion: a finite element-based study
    Wu, Ting-kui
    Meng, Yang
    Wang, Bei-yu
    Rong, Xin
    Hong, Ying
    Ding, Chen
    Chen, Hua
    Liu, Hao
    BMC MUSCULOSKELETAL DISORDERS, 2019, 20 (1)
  • [27] BIOMECHANICAL STUDY OF THE CERVICAL SPINE WITH DISC IMPLANTS: A FINITE ELEMENT ANALYSIS
    Szkoda, K.
    Galaska, P.
    Zak, M.
    Pezowicz, C.
    ENGINEERING MECHANICS 2017, 2017, : 966 - 969
  • [28] The Safety of Single and Multilevel Cervical Total Disc Replacement in Ambulatory Surgery Centers
    Cuellar, Jason M.
    Lanman, Todd H.
    Rasouli, Alexandre
    SPINE, 2020, 45 (08) : 512 - 521
  • [29] Comparison of Cervical Spine Biomechanics After Fixed- and Mobile-Core Artificial Disc Replacement: A Finite Element Analysis
    Lee, Sang-Hun
    Im, Yang-Jin
    Kim, Ki-Tack
    Kim, Yoon-Hyuk
    Park, Won-Man
    Kim, Kyungsoo
    SPINE, 2011, 36 (09) : 700 - 708
  • [30] FINITE ELEMENT ANALYSIS OF CERVICAL SPINE WITH DIFFERENT CONSTRAINED TYPES OF TOTAL DISC REPLACEMENT
    Lin, Chien-Yu
    Chuang, Shih-Youeng
    Chiang, Chang-Jung
    Tsuang, Yang-Hwei
    Chen, Weng-Pin
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2014, 14 (03)