Experimental study on the effect of condensate water on the performance of split air conditioning system

被引:23
|
作者
Yang, Hua [1 ,3 ]
Pei, Na [1 ,2 ]
Liu, Liansheng [1 ,3 ]
Fan, Man [1 ,3 ]
Qin, Yue [1 ]
机构
[1] Hebei Univ Technol, Sch Energy & Environm Engn, Tianjin 300401, Peoples R China
[2] North China Univ Sci & Technol, Qinggong Coll, Tangshan 063000, Peoples R China
[3] Hebei Key Lab Thermal Sci & Energy Clean Utilizat, Tianjin, Peoples R China
关键词
Split air conditioner; Condensate water; Unit performance; Energy efficiency ratio; IMPROVED ENERGY PERFORMANCE; COOLED CHILLER; ENHANCEMENT; HOT;
D O I
10.1016/j.egyr.2021.01.037
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A method of using condensate water to reduce the airflow temperature around the air conditioner condenser and improve the performance of air conditioner is presented in this study. The structure of traditional split air conditioner is adjusted by changing the installation direction of fan and adding disk-type atomization cooling element (ACE) in the outdoor unit. The performance of the air conditioner under four modes is tested in different environment temperatures. Four modes were named, i.e. the original unit without ACE, original unit with ACE, blowing mode without condensate water and blowing mode with condensate water. The blowing mode with condensate water is used to pre-cool the incoming airflow, and the maximum temperature reduction at the air outlet surface of the condenser is up to 2.2 degrees C in 35 degrees C. With the environment temperature increasing, the refrigerating capacity of four modes decreased, and the power consumption increased, leading to the decrease of EER. However, owing to the cooling effect of condensate water, the performance of blowing mode with condensate water was greatly improved compared with the original unit without ACE. The variation rates of refrigerating capacity, power consumption and EER at environment temperature of 43 degrees C were 8.1%,-9.5% and 20%, respectively. The unit with condensate water could greatly improve the performance of air conditioning in high environment temperatures. (C) 2021 The Author(s). Published by Elsevier Ltd.
引用
收藏
页码:840 / 851
页数:12
相关论文
共 50 条
  • [21] Experimental Study for the Effect of Pre-Cooling the Condenser Inlet Air of Split Type Air Conditioning Unit
    Faisal, Safaa H.
    Hammadi, Salman H.
    Mutlag, Saif S.
    ENGINEERING JOURNAL-THAILAND, 2018, 22 (05): : 67 - 85
  • [22] Experimental study of hydraulic stability for variable water volume air conditioning System
    Chang, Sainan
    Meng, Qinglong
    Liang, Yuxiao
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 1072 - 1078
  • [23] EXPERIMENTAL STUDY THE PERFORMANCE OF HYBRID SERPENTINE SOLAR COLLECTOR IN AIR CONDITIONING SYSTEM
    Gatea, Hawraa T.
    Hasson, Atheer S.
    Alwan, Adil A.
    Jabbar, Mohammed Y.
    Abed, Azher M.
    FRONTIERS IN HEAT AND MASS TRANSFER, 2022, 18 : 1 - 6
  • [24] EXPERIMENTAL STUDY ON THE THERMAL PERFORMANCE OF AN AIR CONDITIONING SYSTEM IN A PURE ELECTRIC VEHICLE
    Liu, Enhai
    Li, Haijun
    Gong, Yajun
    Wei, Yuping
    Chen, Haifei
    THERMAL SCIENCE, 2021, 25 (03): : 2093 - 2099
  • [25] Performance Evaluation and Experimental Study of the Induction Radiant Air-conditioning System
    Si, Qiang
    Zhang, Xiaosong
    9TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING (ISHVAC) JOINT WITH THE 3RD INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT (COBEE), 2015, 121 : 1795 - 1804
  • [26] Experimental and computer performance study of an automotive air conditioning system with alternative refrigerants
    Joudi, KA
    Mohammed, ASK
    Aljanabi, MK
    ENERGY CONVERSION AND MANAGEMENT, 2003, 44 (18) : 2959 - 2976
  • [27] Experimental Investigation on the Performance of Condenser for Charge Reduction of HC-290 in a Split Air-Conditioning System
    Saravanan, Ayyamperumal Lalitha
    Lal, Dhasan Mohan
    Selvam, Chandrasekaran
    HEAT TRANSFER ENGINEERING, 2020, 41 (17) : 1499 - 1511
  • [28] Quantitative and qualitative characteristics of condensate water of home air-conditioning system in Iran
    Alipour, Vali
    Mahvi, Amir Hossein
    Rezaei, Leila
    DESALINATION AND WATER TREATMENT, 2015, 53 (07) : 1834 - 1839
  • [29] Performance evaluation of a central air conditioning system using condensate as a discharge line cooler
    Sumeru, Kasni
    Pramudantoro, Triaji Pangripto
    Badarudin, Apip
    Setyawan, Andriyanto
    Sumeru, Husain Akbar
    bin Sukri, Mohamad Firdaus
    Sulaimon, Shodiya
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 63
  • [30] Experimental Study of a Hybrid System of Air Conditioning Coupled with the Distillate Water Production Unit
    Kabeel, A. E.
    Abdelgaied, Mohamed
    Zakaria, Yehya
    CENTRAL EUROPEAN SYMPOSIUM ON THERMOPHYSICS 2019 (CEST), 2019, 2133