Precision timing photon detectors using Cadmium-Telluride sensors

被引:0
|
作者
Bornheim, A. [1 ]
Mangu, A. [1 ]
Mao, J. [1 ]
Pena, C. [1 ]
Spiropulu, M. [1 ]
Xie, S. [1 ]
Zhang, Z. [1 ]
机构
[1] CALTECH, Pasadena, CA 91125 USA
关键词
Cadmium-Telluride; Precision timing; Calorimeter;
D O I
10.1016/j.nima.2017.11.095
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Precision timing properties of high energy physics detectors in high luminosity colliders has become an important requirement for the success of particle detection, of which new calorimeter with timing precision of few tens of ps is the main interest. In this paper, we presented the first calorimetry and timing performance measurement of Cadmium-Telluride (CdTe) as the active material of sampling calorimeter, using 2 GeV to 200 GeV electron beam from CERN beam lines. A good energy performance is achieved due to the better sensitivity of CdTe to X ray photons in the secondary shower than other semi-conducting sensors such as silicon. The timing resolution of the tested CdTe sensor is measured to be down to 21 ps under the best conditions. (c) 2017 Published by Elsevier B.V.
引用
收藏
页码:300 / 302
页数:3
相关论文
共 50 条
  • [41] COLLIMATION OF PORTABLE CADMIUM TELLURIDE DETECTORS FOR BIOTELEMETRY
    BOJSEN, J
    STABERG, B
    KOLENDORF, K
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1982, 33 (12): : 1359 - 1363
  • [42] MERCURY CADMIUM TELLURIDE DETECTORS FOR THERMAL IMAGING
    KNOWLES, P
    GEC JOURNAL OF RESEARCH, 1984, 2 (03): : 141 - 156
  • [43] Effect of Heat Treatment on the Surface Parameters of Cadmium-Telluride Single-Crystal Substrates
    Makhniy, V. P.
    German, I. I.
    Tchernykh, E. I.
    JOURNAL OF SURFACE INVESTIGATION, 2013, 7 (03): : 562 - 564
  • [44] Photon absorption coefficient and the Franz-Keldysh shift of cutoff wavelength for mercury cadmium telluride detectors
    Ye, YT
    Luo, JY
    Li, JX
    Ye, L
    Hong, YH
    Shu, HH
    Li, ZD
    APPLIED OPTICS, 1997, 36 (12): : 2448 - 2451
  • [45] Enhanced Photon Absorption in Subwavelength Mercury Cadmium Telluride Layer for Infrared Detectors Operating at Higher Temperature
    Sojib, Md.
    Sayeed, R.
    Avrutin, V.
    Ozgur, U.
    Dhar, N. K.
    2023 IEEE PHOTONICS CONFERENCE, IPC, 2023,
  • [46] Evaluation of Energy Loss and Charge Sharing in Cadmium Telluride Detectors for Photon-Counting Computed Tomography
    Xu, Cheng
    Danielsson, Mats
    Bornefalk, Hans
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (03) : 614 - 625
  • [47] Feasibility of using cadmium-zinc-telluride detectors in electronically collimated SPECT
    Univ of Southern California, Los Angeles, United States
    IEEE Trans Nucl Sci, 4 pt 1 (1139-1146):
  • [48] Using cadmium telluride detectors for monitoring the hermetic sealing of fuel element jackets
    Alekseeva, L.A.
    Ivanov, V.I.
    Maklakov, V.V.
    Polyakov, V.I.
    Soviet atomic energy, 1991, 69 (04): : 862 - 864
  • [49] Preliminary uranium enrichment analysis results using cadmium zinc telluride detectors
    Lavietes, AD
    McQuaid, JH
    Paulus, TJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 380 (1-2): : 406 - 409
  • [50] FEASIBILITY OF USING CADMIUM-ZINC-TELLURIDE DETECTORS IN ELECTRONICALLY COLLIMATED SPECT
    SINGH, M
    DOTY, FP
    FRIESENHAHN, SJ
    BUTLER, JF
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) : 1139 - 1146