Precision timing photon detectors using Cadmium-Telluride sensors

被引:0
|
作者
Bornheim, A. [1 ]
Mangu, A. [1 ]
Mao, J. [1 ]
Pena, C. [1 ]
Spiropulu, M. [1 ]
Xie, S. [1 ]
Zhang, Z. [1 ]
机构
[1] CALTECH, Pasadena, CA 91125 USA
关键词
Cadmium-Telluride; Precision timing; Calorimeter;
D O I
10.1016/j.nima.2017.11.095
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Precision timing properties of high energy physics detectors in high luminosity colliders has become an important requirement for the success of particle detection, of which new calorimeter with timing precision of few tens of ps is the main interest. In this paper, we presented the first calorimetry and timing performance measurement of Cadmium-Telluride (CdTe) as the active material of sampling calorimeter, using 2 GeV to 200 GeV electron beam from CERN beam lines. A good energy performance is achieved due to the better sensitivity of CdTe to X ray photons in the secondary shower than other semi-conducting sensors such as silicon. The timing resolution of the tested CdTe sensor is measured to be down to 21 ps under the best conditions. (c) 2017 Published by Elsevier B.V.
引用
收藏
页码:300 / 302
页数:3
相关论文
共 50 条
  • [31] FULL-ENERGY PEAK EFFICIENCY OF CADMIUM-TELLURIDE GAMMA-RAY SPECTROMETERS
    SIFFERT, P
    GONIDEC, JP
    CORNET, A
    BELL, RO
    WALD, FV
    NUCLEAR INSTRUMENTS & METHODS, 1974, 115 (01): : 13 - 21
  • [32] POLARIZATION IN CADMIUM TELLURIDE NUCLEAR RADIATION DETECTORS
    SIFFERT, P
    BERGER, J
    SCHARAGER, C
    CORNET, A
    STUCK, R
    BELL, RO
    SERREZE, HB
    WALD, FV
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1976, 23 (01) : 159 - 170
  • [33] APPLICATIONS OF CADMIUM TELLURIDE NUCLEAR RADIATION DETECTORS
    BEAVIN, RC
    SNOWBALL, HM
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1970, NS17 (01) : 65 - &
  • [34] CADMIUM TELLURIDE X-RAY DETECTORS
    MASLOVA, LV
    MATVEEV, OA
    RYVKIN, SM
    TERENTEV, AI
    KHUSAINOV, AK
    REVUE DE PHYSIQUE APPLIQUEE, 1977, 12 (02): : 291 - 292
  • [35] Collimation of portable cadmium telluride detectors for biotelemetry
    Bojsen, J.
    Staberg, B.
    Kolendorf, K.
    International Journal of Applied Radiation and Isotopes, 1982, 33 (12): : 1359 - 1363
  • [36] Study of the homogeneity of Cadmium Zinc Telluride detectors
    Hermon, H
    Schieber, M
    Yang, N
    James, RB
    Kolesnikov, NNP
    Ivanov, YN
    Komar, V
    Goorsky, MS
    Yoon, H
    Toney, J
    Schlesinger, TE
    SEMICONDUCTORS FOR ROOM-TEMPERATURE RADIATION DETECTOR APPLICATIONS II, 1997, 487 : 223 - 228
  • [37] Photon-induced modifications in cadmium telluride/mercury cadmium telluride heterostructure interfaces
    Agnihotri, OP
    Sehgal, HK
    Pal, R
    Gopal, V
    APPLIED PHYSICS LETTERS, 2000, 77 (09) : 1330 - 1332
  • [38] ION IMPLANTED CONTACTS ON CADMIUM TELLURIDE DETECTORS
    CORNET, A
    STUCK, R
    SIFFERT, P
    GROB, JJ
    HAGEALI, M
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1972, NS19 (03) : 358 - &
  • [39] CURRENT POSSIBILITIES AND LIMITATIONS OF CADMIUM TELLURIDE DETECTORS
    SIFFERT, P
    NUCLEAR INSTRUMENTS & METHODS, 1978, 150 (01): : 1 - 12
  • [40] PERFORMANCE OF MERCURY CADMIUM TELLURIDE PHOTOCONDUCTIVE DETECTORS
    JOZWIKOWSKA, A
    JOZWIKOWSKI, K
    ROGALSKI, A
    INFRARED PHYSICS, 1991, 31 (06): : 543 - 554