Probe Oscillation Shear Elastography (PROSE): A High Frame-Rate Method for Two-Dimensional Ultrasound Shear Wave Elastography

被引:31
|
作者
Mellema, Daniel C. [1 ,2 ]
Song, Pengfei [2 ]
Kinnick, Randall R. [3 ]
Urban, Matthew W. [2 ]
Greenleaf, James F. [3 ]
Manduca, Armando [3 ]
Chen, Shigao [2 ]
机构
[1] Mayo Clin, Coll Med, Mayo Grad Sch, Rochester, MN 55905 USA
[2] Mayo Clin, Coll Med, Dept Radiol, Rochester, MN 55905 USA
[3] Mayo Clin, Coll Med, Dept Physiol & Biomed Engn, Rochester, MN 55905 USA
基金
美国国家卫生研究院;
关键词
Inclusion; mechanical vibration; shear wave; ultrasound elastography; MAGNETIC-RESONANCE ELASTOGRAPHY; ACOUSTIC RADIATION FORCE; TRANSIENT ELASTOGRAPHY; TISSUE ELASTICITY; BIOLOGICAL TISSUES; SOFT-TISSUES; IN-VIVO; MODULUS; TECHNOLOGY; VIBRATION;
D O I
10.1109/TMI.2016.2550007
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Ultrasound shear wave elastography (SWE) utilizes the propagation of induced shear waves to characterize the shear modulus of soft tissue. Many methods rely on an acoustic radiation force (ARF) "push beam" to generate shear waves. However, specialized hardware is required to generate the push beams, and the thermal stress that is placed upon the ultrasound system, transducer, and tissue by the push beams currently limits the frame-rate to about 1 Hz. These constraints have limited the implementation of ARF to high-end clinical systems. This paper presents Probe Oscillation Shear Elastography (PROSE) as an alternative method to measure tissue elasticity. PROSE generates shear waves using a harmonic mechanical vibration of an ultrasound transducer, while simultaneously detecting motion with the same transducer under pulse-echo mode. Motion of the transducer during detection produces a "strain-like" compression artifact that is coupled with the observed shear waves. A novel symmetric sampling scheme is proposed such that pulse-echo detection events are acquired when the ultrasound transducer returns to the same physical position, allowing the shear waves to be decoupled from the compression artifact. Full field-of-view (FOV) two-dimensional (2D) shear wave speed images were obtained by applying a local frequency estimation (LFE) technique, capable of generating a 2D map from a single frame of shear wave motion. The shear wave imaging frame rate of PROSE is comparable to the vibration frequency, which can be an order of magnitude higher than ARF based techniques. PROSE was able to produce smooth and accurate shear wave images from three homogeneous phantoms with different moduli, with an effective frame rate of 300 Hz. An inclusion phantom study showed that increased vibration frequencies improved the accuracy of inclusion imaging, and allowed targets as small as 6.5 mm to be resolved with good contrast (contrast-to-noise ratio >= 19 dB) between the target and background.
引用
收藏
页码:2098 / 2106
页数:9
相关论文
共 50 条
  • [1] Pancreas ultrasound two-dimensional shear wave elastography in healthy children
    Qiu, Lisa
    Trout, Andrew T.
    Bennett, Paula S.
    Dillman, Jonathan R.
    [J]. PEDIATRIC RADIOLOGY, 2021, 51 (03) : 403 - 409
  • [2] Pancreas ultrasound two-dimensional shear wave elastography in healthy children
    Lisa Qiu
    Andrew T. Trout
    Paula S. Bennett
    Jonathan R. Dillman
    [J]. Pediatric Radiology, 2021, 51 : 403 - 409
  • [3] TWO-DIMENSIONAL AND SHEAR WAVE ELASTOGRAPHY ULTRASOUND: A RELIABLE METHOD TO ANALYSE SPASTIC MUSCLES?
    Mathevon, Laure
    Michel, F.
    Aubry, S.
    Testa, R.
    Lapole, T.
    Arnaudeau, L. F.
    Fernandez, B.
    Parratte, B.
    Calmels, P.
    [J]. MUSCLE & NERVE, 2018, 57 (02) : 222 - 228
  • [4] Artifacts in two-dimensional shear wave elastography of liver
    Hui-Peng Wang
    Peng-Chao Zheng
    Xue-Mei Wang
    Liang Sang
    [J]. World Journal of Gastroenterology, 2023, (21) : 3318 - 3327
  • [5] Artifacts in two-dimensional shear wave elastography of liver
    Wang, Hui-Peng
    Zheng, Peng-Chao
    Wang, Xue-Mei
    Sang, Liang
    [J]. WORLD JOURNAL OF GASTROENTEROLOGY, 2023, 29 (21) : 3318 - 3327
  • [6] Interconversion of elasticity measurements between two-dimensional shear wave elastography and transient elastography
    Kim, Yeun-Yoon
    Kim, Myung-Joon
    Shin, Hyun Joo
    Yoon, Haesung
    Kim, Ha Yan
    Lee, Mi-Jung
    [J]. MEDICAL ULTRASONOGRAPHY, 2018, 20 (02) : 127 - 133
  • [7] Diagnostic problems in two-dimensional shear wave elastography of the liver
    Naganuma, Hiroko
    Ishida, Hideaki
    Uno, Atsushi
    Nagai, Hiroshi
    Kuroda, Hidekatsu
    Ogawa, Masahiro
    [J]. WORLD JOURNAL OF RADIOLOGY, 2020, 12 (05): : 76 - 86
  • [8] Comparison of two-dimensional shear wave elastography and point shear wave elastography techniques with magnetic resonance findings in detection of patellar tendinopathy
    Yurdaisik, Isil
    [J]. EKLEM HASTALIKLARI VE CERRAHISI-JOINT DISEASES AND RELATED SURGERY, 2019, 30 (03): : 275 - 281
  • [9] Three-dimensional shear-wave elastography for differentiating benign and malignant breast lesions: comparison with two-dimensional shear-wave elastography
    Ji Hyun Youk
    Hye Mi Gweon
    Eun Ju Son
    Jin Chung
    Jeong-Ah Kim
    Eun-kyung Kim
    [J]. European Radiology, 2013, 23 : 1519 - 1527
  • [10] Two-Dimensional Shear-Wave Elastography for Kidney Stiffness Assessment
    Grosu, Iulia
    Bob, Flaviu
    Sporea, Ioan
    Popescu, Alina
    Sirli, Roxana
    Schiller, Adalbert
    [J]. ULTRASOUND QUARTERLY, 2021, 37 (02) : 144 - 148