Two-Dimensional Shear-Wave Elastography for Kidney Stiffness Assessment

被引:16
|
作者
Grosu, Iulia [1 ]
Bob, Flaviu [1 ]
Sporea, Ioan [2 ]
Popescu, Alina [2 ]
Sirli, Roxana [2 ]
Schiller, Adalbert [1 ]
机构
[1] Victor Babes Univ Med & Pharm, Dept Nephrol, 156 L Rebreanu Bd, Timisara, Romania
[2] Victor Babes Univ Med & Pharm, Dept Gastroenterol & Hepatol, Timisara, Romania
关键词
chronic kidney disease; shear waves; shear-wave elastography; ultrasound elastography; TRANSIENT ELASTOGRAPHY; LIVER FIBROSIS; CLINICAL-USE; ULTRASOUND; ELASTICITY; EXPERIENCE; DIAGNOSIS; DISEASE; VALUES;
D O I
10.1097/RUQ.0000000000000461
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study aimed to analyze the utility of bidimensional shear-wave elastography for renal assessment and in the prediction of chronic kidney disease (CKD). The study included 92 subjects: 50 healthy volunteers and 42 patients with different degrees of CKD (mean age, 57.5 +/- 13.4; 50% were female), excluding those undergoing renal replacement therapies, obstructive pathology, or renal lithiasis. We performed kidney shear-wave velocity (KSWV) determinations in the midportion of the parenchyma of each kidney. The median values were expressed in meters per second. We obtained successful assessments in 94% of the cases for the right kidney (RK) and 90.2% for the left kidney (LK), with an intraclass correlation coefficient of 0.96 (RK) and 0.91 (LK). We obtained significantly lower KSWV values in the CKD lot as opposed to the healthy volunteers: RK: 1.38 +/- 0.1 versus 1.78 +/- 0.1 m/s, P = 0.05; LK: 1.37 +/- 0.1 m/s versus 1.72 +/- 0.1 m/s. We could predict the presence of CKD with a sensitivity of 89.2% and a specificity of 76.9% for a KSWV of less than 1.47 m/s, with a tendency of KSWV to decrease with CKD progression. Our study shows that KSWV measured using bidimensional shear-wave elastography decreases in patients with CKD compared with normal subjects, and that for a cutoff value of below 1.47 m/s we could predict, with a good sensitivity and specificity, the presence of CKD.
引用
收藏
页码:144 / 148
页数:5
相关论文
共 50 条
  • [1] Reliability and applicability of two-dimensional shear-wave elastography for the evaluation of liver stiffness
    Varbobitis, Ioannis C.
    Siakavellas, Spyros I.
    Koutsounas, Ioannis S.
    Karagiannakis, Dimitrios S.
    Ioannidou, Panagiota
    Papageorgiou, Maria-Vasiliki
    Pavlopoulou, Ioanna D.
    Schizas, Dimitrios
    Bamias, Giorgos
    Vlachogiannakos, Ioannis
    Ladas, Spyros D.
    Papatheodoridis, George V.
    EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2016, 28 (10) : 1204 - 1209
  • [2] TWO-DIMENSIONAL SHEAR-WAVE ELASTOGRAPHY FOR ASSESSMENT OF LIVER FIBROSIS IN CHILDREN
    Kofinova, Denitza
    Shentova-Eneva, Rayna
    Hadzhiyski, Petyo
    Baycheva, Mila
    Kyoseva-Shishkova, Diana
    Yaneva, Penka
    Avdjieva-Tzavella, Daniela
    COMPTES RENDUS DE L ACADEMIE BULGARE DES SCIENCES, 2021, 74 (10): : 1565 - 1570
  • [3] Three-dimensional shear-wave elastography for differentiating benign and malignant breast lesions: comparison with two-dimensional shear-wave elastography
    Ji Hyun Youk
    Hye Mi Gweon
    Eun Ju Son
    Jin Chung
    Jeong-Ah Kim
    Eun-kyung Kim
    European Radiology, 2013, 23 : 1519 - 1527
  • [4] Three-dimensional shear-wave elastography for differentiating benign and malignant breast lesions: comparison with two-dimensional shear-wave elastography
    Youk, Ji Hyun
    Gweon, Hye Mi
    Son, Eun Ju
    Chung, Jin
    Kim, Jeong-Ah
    Kim, Eun-kyung
    EUROPEAN RADIOLOGY, 2013, 23 (06) : 1519 - 1527
  • [5] Liver fibrosis with two-dimensional shear-wave elastography in patients with autoimmune hepatitis
    Xing, Xian
    Yan, Yuling
    Shen, Yi
    Xue, Mei
    Wang, Xiaoze
    Luo, Xuefeng
    Yang, Li
    EXPERT REVIEW OF GASTROENTEROLOGY & HEPATOLOGY, 2020, 14 (07) : 631 - 638
  • [6] Noninvasive Evaluation of Liver Fibrosis by Using Two-dimensional Shear-Wave Elastography
    Ozturker, Coskun
    Karagoz, Ergenekon
    Mutlu, Hakan
    RADIOLOGY, 2016, 280 (01) : 323 - 324
  • [7] Intra-individual comparison of liver stiffness measurements by magnetic resonance elastography and two-dimensional shear-wave elastography in 888 patients
    Ichikawa, Hideo
    Yasuda, Eisuke
    Kumada, Takashi
    Takeshima, Kenji
    Ogawa, Sadanobu
    Tsunekawa, Akikazu
    Goto, Tatsuya
    Nakaya, Koji
    Akita, Tomoyuki
    Tanaka, Junko
    ULTRASONOGRAPHY, 2023, 42 (01) : 65 - 77
  • [8] Liver Stiffness Measured by Two-Dimensional Shear-Wave Elastography: Prognostic Value after Radiofrequency Ablation for Hepatocellular Carcinoma
    Lee, Dong Ho
    Lee, Jeong Min
    Yoon, Jung-Hwan
    Kim, Yoon Jun
    Lee, Jeong-Hoon
    Yu, Su Jong
    Han, Joon Koo
    LIVER CANCER, 2018, 7 (01) : 65 - 75
  • [9] Noninvasive Evaluation of Liver Fibrosis by Using Two-dimensional Shear-Wave Elastography Response
    Zheng, Jian
    Zheng, Rongqin
    RADIOLOGY, 2016, 280 (01) : 324 - 324
  • [10] The Emerging Role of Two-dimensional US Shear-Wave Elastography in Chronic Liver Disease
    Chauhan, Anil
    RADIOLOGY, 2018, 289 (02) : 416 - 417