Clinical implementation of proton Monte Carlo dose calculation

被引:0
|
作者
Paganetti, H [1 ]
Jiang, H [1 ]
Kollipara, S [1 ]
机构
[1] Massachusetts Gen Hosp, NE Proton Therapy Ctr, Boston, MA 02114 USA
关键词
D O I
10.1118/1.1998066
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Clinical use of Monte Carlo dose calculation to support routine treatment planning and delivery at the Northeast Proton Therapy Center. Method and Materials: The Monte Carlo code GEANT4 was used to model the treatment heads. More than 1000 objects were considered in the geometry. This includes a time dependent simulation of the modulator wheel (broad beam modulation) and the magnetic field settings (beam scanning). The code was benchmarked against phantom measurements. Further, the capability of using CT data information was implemented in GEANT4. Different Hounsfield unit to material conversion methods were tested. The standard GEANT4 tracking algorithm was modified to allow time‐efficient dose calculation. A software link of the Monte Carlo dose engine to the patient database and the commercial planning system was established. Results: The setup for Monte Carlo dose calculation is automated via a user interface. Information from the commercial treatment planning system and the treatment machine control software is imported to generate Monte Carlo input files. Dose calculations have been performed for radiosurgery and for breast, paranasal sinus, spine, and lung malignancies. Monte Carlo dose distributions can be imported into the planning system for analysis. Differences to the planning program could be identified. Due to the detailed model of the treatment head, Monte Carlo is also being used for absolute dosimetry. The reading of the segmented parallel plate ionization chamber in the treatment head was simulated with 1.4 % accuracy. Output factors can thus be simulated using the patient geometry. Conclusion: Proton Monte Carlo dose calculation for treatment planning support can be efficiently done using GEANT4 based software. Re‐calculated plans can be used for decision making in the planning process. Simulated output factors allow the use of Monte Carlo for absolute dosimetry. This is the first clinically implemented complete Monte Carlo for proton therapy. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2028 / 2028
页数:1
相关论文
共 50 条
  • [21] Experimental Validation of Clinical as Well as Monte Carlo Dose Calculation for Proton Therapy of Lung Cancer Patients
    Grassberger, C.
    Daartz, J.
    Dowdell, S.
    Verburg, J.
    Sharp, G.
    Paganetti, H.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [22] Validation of Monte-Carlo Proton Dose Calculation for Real Tissue Samples
    Wang, H.
    Wu, J.
    Zhang, R.
    Baer, E.
    Geng, C.
    Jee, K.
    Sharp, G.
    Paganetti, H.
    Tang, J.
    Lu, H.
    [J]. MEDICAL PHYSICS, 2017, 44 (06)
  • [23] Development of a Framework for Monte Carlo Dose Calculation of Intensity Modulated Proton Plans
    Loebner, H. A.
    Frei, D.
    Volken, W.
    Mueller, S.
    Aebersold, D. M.
    Stampanoni, M. F. M.
    Manser, P.
    Fix, M. K.
    Kueng, R.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E742 - E742
  • [24] Real-time hybrid Monte Carlo for dose calculation in proton therapy
    Ibanez, P.
    Valladolid, V.
    Villa-Abaunza, A.
    Espinosa, A.
    Arias, F.
    Galve, P.
    Sanchez-Parcerisa, D.
    Udias, J. M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1532 - S1533
  • [25] Characterizing a proton beam scanning system for Monte Carlo dose calculation in patients
    Grassberger, C.
    Lomax, Anthony
    Paganetti, H.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (02): : 633 - 645
  • [26] GPU-based fast Monte Carlo dose calculation for proton therapy
    Jia, Xun
    Schuemann, Jan
    Paganetti, Harald
    Jiang, Steve B.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (23): : 7783 - 7797
  • [27] FRoG dose computation meets Monte Carlo accuracy for proton therapy dose calculation in lung
    Magro, Giuseppe
    Mein, Stewart
    Kopp, Benedikt
    Mastella, Edoardo
    Pella, Andrea
    Ciocca, Mario
    Mairani, Andrea
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 86 : 66 - 74
  • [28] Clinical Implementation and Application of Monte Carlo Methods in Photon and Electron Dose Calculation - New Issues to Consider in Clinical Practice
    Tyagi, N.
    Cygler, J.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [29] On the evaluation and implementation of efficient sampling algorithms for Monte Carlo based dose calculation
    Chetty, IJ
    DeMarco, JJ
    Solberg, TD
    [J]. USE OF COMPUTERS IN RADIATION THERAPY, 2000, : 428 - 430
  • [30] GPU-accelerated Monte Carlo convolution/superposition implementation for dose calculation
    Zhou, Bo
    Yu, Cedric X.
    Chen, Danny Z.
    Hu, X. Sharon
    [J]. MEDICAL PHYSICS, 2010, 37 (11) : 5593 - 5603