Swept source optical coherence tomography with external clocking using voltage controlled oscillator

被引:1
|
作者
Lee, Eung Je [1 ]
Kim, Yong Pyung [1 ]
机构
[1] Kyung Hee Univ, Coll Elect & Informat, Inst Laser Engn, Yongin 446701, Gyeonggi Do, South Korea
关键词
wavelength-swept source; frequency domain optical coherence tomography; Fourier domain mode-locked laser; recalibration of beat frequency broadening; DOMAIN MODE-LOCKING; SEMICONDUCTOR-LASER; LOCKED LASER; NM; FDML;
D O I
10.1117/1.3577705
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In this study, a beat signal recalibration method was developed for optical coherence tomography (OCT) with a high-speed wavelength-swept source. By adopting a voltage-controlled oscillator (VCO) modulated by a sinusoidal waveform as a trigger for the OCT system, the broadening of the beat frequency due to laser tuning rate variations was recalibrated. For this study, OCT based on a Fourier domain mode-locked (FDML) laser at a sweep rate of 60.9 kHz was demonstrated. OCT images of 1500x409 pixels were obtained with the sensitivity of 100 dB. Temporal frequency variations in the FDML laser and OCT images obtained with the proposed technique were also described. When compared to a conventional recalibration method using optical components, swept source optical coherence tomography operated with a VCO clock exhibited superior performance and high stability. From the experimental results, it was demonstrated that the proposed method is sufficient to recalibrate the time-frequency variations in interferometry with a high-speed wavelength-swept source. (C) 2011 Society of Photo-Optical Instrumentation Engineers (SPIE). [DOI: 10.1117/1.3577705]
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Swept Source Optical Coherence Tomography: a Review
    Yasin Alibhai A.
    Or C.
    Witkin A.J.
    [J]. Current Ophthalmology Reports, 2018, 6 (1) : 7 - 16
  • [2] Advances in swept-source optical coherence tomography and optical coherence tomography angiography
    Zheng, Fang
    Deng, Xiaofeng
    Zhang, Qi
    He, Jingliang
    Ye, Panpan
    Liu, Shan
    Li, Peng
    Zhou, Jian
    Fang, Xiaoyun
    [J]. ADVANCES IN OPHTHALMOLOGY PRACTICE AND RESEARCH, 2023, 3 (02): : 67 - 79
  • [3] Identification of Ink Marks Using Swept Source Optical Coherence Tomography
    Wu Tonh
    Wu Chao
    Pan Ruibin
    Zhang Lei
    He Chongjun
    Wang Jiming
    Lu Yuangang
    Liu Youwen
    [J]. CHINESE JOURNAL OF LASERS-ZHONGGUO JIGUANG, 2020, 47 (11):
  • [4] Assessing Embryo Development using Swept Source Optical Coherence Tomography
    Caujolle, S.
    Cernat, R.
    Silvestri, G.
    Marques, M. J.
    Bradu, A.
    Feuchter, T.
    Robinson, G.
    Griffin, D.
    Podoleanu, A.
    [J]. 2ND CANTERBURY CONFERENCE ON OCT WITH EMPHASIS ON BROADBAND OPTICAL SOURCES, 2018, 10591
  • [5] Quantification of the Posterior Cornea Using Swept Source Optical Coherence Tomography
    Wahlig, Stephen
    Yam, Gary Hin-Fai
    Chong, Wesley
    Seah, Xin-Yi
    Kocaba, Viridiana
    Ang, Marcus
    Htoon, Hla Myint
    Tun, Tin A.
    Ong, Hon Shing
    Mehta, Jodhbir S.
    [J]. TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2018, 7 (05):
  • [6] A study on optical coherence tomography using high frequency swept source
    Ding, Lei
    Tong, Xinglin
    Chen, Liang
    Hu, Pan
    Huang, Di
    Zhao, Minli
    Wen, Hongqiao
    [J]. IMAGE SENSING TECHNOLOGIES: MATERIALS, DEVICES, SYSTEMS, AND APPLICATIONS III, 2016, 9854
  • [7] Cataract quantification using swept-source optical coherence tomography
    Panthier, Christophe
    Saad, Main
    Rouger, Helene
    Gatinel, Damien
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (06): : 893 - 894
  • [8] Cataract quantification using swept-source optical coherence tomography
    Bras, Joao E. G.
    Sickenberger, Wolfgang
    Hirnschall, Nino
    Findl, Oliver
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (12): : 1478 - 1481
  • [9] Swept source optical coherence tomography in globe perforation
    Dubey, Devashish
    Shanmugam, Mahesh
    Ramanjulu, Rajesh
    Mishra, K. C. Divyansh
    Doshi, Bindiya
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (10) : 1697 - +
  • [10] Handheld swept source optical coherence tomography angiography
    Liu, Gangjun
    Yang, Jianlong
    Liu, Liang
    Campbell, J. Peter
    Huang, David
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)