Ultrasound assessment of pubertal breast development in girls: intra- and interobserver agreement

被引:8
|
作者
Bruserud, Ingvild Saervold [1 ,2 ]
Roelants, Mathieu [3 ]
Oehme, Ninnie Helen Bakken [1 ,2 ]
Eide, Geir Egil [4 ,5 ]
Bjerknes, Robert [1 ,2 ]
Rosendahl, Karen [6 ,7 ]
Juliusson, Petur B. [1 ,2 ]
机构
[1] Univ Bergen, Dept Clin Sci, Bergen, Norway
[2] Haukeland Hosp, Dept Pediat, Bergen, Norway
[3] Univ Leuven, KU Leuven, Dept Publ Hlth & Primary Care, Leuven, Belgium
[4] Haukeland Hosp, Clin Res Ctr, Bergen, Norway
[5] Univ Bergen, Dept Global Publ Hlth & Primary Care, Bergen, Norway
[6] Haukeland Hosp, Dept Radiol, Bergen, Norway
[7] Univ Bergen, Dept Clin Med, Bergen, Norway
关键词
Breast development; Children; Measurement error; Observer agreement; Pubertal staging; Ultrasound; PRECOCIOUS PUBERTY; ADOLESCENTS; CHILDREN; MASSES; US;
D O I
10.1007/s00247-018-4188-7
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background Clinical assessment of pubertal breast development using Tanner staging is subjective. This has led to the introduction of ultrasound (US), aiming for a more objective analysis. However, information regarding its reliability is lacking. Objective To examine intra- and interobserver agreement of breast maturity staging using US and to examine the precision of direct measurements of the gland. Materials and methods Fifty-seven healthy girls (mean age: 10.9 years, range: 6.1 to 15.9 years) were examined independently by two observers using US of the left breast to score the glandular maturity stage on a 0-5 scale, and to measure the depth and diameter. One observer repeated the examination after 20 to 35 min to assess intra-observer agreement. Cohen's kappa with linear weights was used to examine intra- and interobserver agreement of the US staging, while the measurement precision was analyzed using Bland-Altman plots and 95% limits of agreement. Results The agreement of US staging on a 0-5 scale was very good (kappa 0.84; 95% confidence interval [CI] 0.78-0.91) for intra-observer observation and good (kappa 0.71; 95% CI 0.62-0.80) for interobserver observation. Measurements of glandular depth and diameter were unbiased for a single observer, but the variances were large both within and between observers. Conclusion US using a scale from 0 to 5 is a reliable method to stage the development of glandular breast tissue during puberty in healthy girls. Measurements of glandular depth and diameter were found to be imprecise.
引用
收藏
页码:1576 / 1583
页数:8
相关论文
共 50 条
  • [41] Interobserver agreement of multicompartment ultrasound in the assessment of pelvic floor anatomy
    Lone, Farah
    Sultan, Abdul H.
    Stankiewicz, Aleksandra
    Thakar, Ranee
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1059):
  • [42] Intra- and interobserver variability of 4D ultrasound examination of the infrarenal aorta
    Derwich, Wojciech
    Wiedemann, Antonia
    Wittek, Andreas
    Filmann, Natalie
    Blase, Christopher
    Schmitz-Rixen, Thomas
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2021, 40 (11) : 2391 - 2402
  • [43] Intra- and interobserver reproducibility of transvaginal ultrasound for the detection and measurement of endometriotic lesions of the bowel
    Chaggar, Prubpreet
    Tellum, Tina
    Cohen, Abigail
    Jurkovic, Davor
    [J]. ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2023, 102 (10) : 1306 - 1315
  • [44] Analysis of agreement between self-assessment and observed classification of pubertal development among school girls
    Guimaraes, JD
    Passos, ADC
    [J]. REVISTA DE SAUDE PUBLICA, 1997, 31 (03): : 263 - 271
  • [45] Intra- and interobserver variability of Kleerekoper's method in vertebral fracture assessment
    Olmez, N
    Kaya, T
    Gunaydin, R
    Vidinli, BD
    Erdogan, N
    Memis, A
    [J]. CLINICAL RHEUMATOLOGY, 2005, 24 (03) : 215 - 218
  • [46] Intra- and interobserver variability of Kleerekoper’s method in vertebral fracture assessment
    Nese Olmez
    Taciser Kaya
    Rezzan Gunaydin
    Berna Dirim Vidinli
    Nezahat Erdogan
    Asuman Memis
    [J]. Clinical Rheumatology, 2005, 24 : 215 - 218
  • [47] Automated Ultrasound of the Breast for Diagnosis: Interobserver Agreement on Lesion Detection and Characterization
    Shin, Hee Jung
    Kim, Hak Hee
    Cha, Joo Hee
    Park, Ju Hyun
    Lee, Kyoung Eun
    Kim, Jeoung Hyun
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (03) : 747 - 754
  • [48] An offline 3D-ultrasonography intra- and interobserver agreement study of fetal cerebral structures
    Buisman, E. T.
    Albers, M. E.
    Onland-Moret, N. C.
    Kahn, R. S.
    Franx, A.
    de Heus, R.
    [J]. BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2017, 124 : 36 - 36
  • [49] Intra- and interobserver agreement of rectus femoris cross-sectional area in critically ill patients
    Hrdy, Ondrej
    Vrbica, Kamil
    Kovar, Marek
    Korbicka, Tomas
    Gal, Roman
    [J]. MINERVA ANESTESIOLOGICA, 2021, 87 (04) : 494 - 495
  • [50] Intra- and Interobserver Agreement in Hallux Valgus Angle Measurements on Weightbearing and Non-Weightbearing Radiographs
    van der Woude, Pieter
    Keizer, Stefan B.
    Wever-Korevaar, Martine
    Thomassen, Bregje J. W.
    [J]. JOURNAL OF FOOT & ANKLE SURGERY, 2019, 58 (04): : 706 - 712