Optimal Path Planning for Robotic Insertion of Steerable Electrode Arrays in Cochlear Implant Surgery

被引:49
|
作者
Zhang, Jian [1 ]
Roland, J. Thomas, Jr. [2 ]
Manolidis, Spiros [3 ]
Simaan, Nabil [1 ]
机构
[1] Columbia Univ, Dept Mech Engn, New York, NY 10027 USA
[2] NYU, Med Ctr, Dept Otolaryngol & Neurosurg, New York, NY 10016 USA
[3] Beth Israel Hosp, Dept Head & Neck Surg, New York, NY 10003 USA
基金
美国国家科学基金会;
关键词
surgical assistance; cochlear implant path planning; underactuated robot; steerable electrode array; STRAIGHT; DESIGN;
D O I
10.1115/1.3039513
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents an optimal path planning method of steerable electrode arrays for robot assisted cochlear implant surgery In this paper, the authors present a novel design of steerable electrode arrays that can actively bend at the up An embedded strand in the electrode array provides an active steering degrees of freedom (DoF) This paper addresses the calibration of the steerable electrode arrays and the optimal path planning for inserting it into planar and three dimensional scala tympani models The goal of the path planning is to minimize the intracochlear forces that the electrode array applies on the walls of the scala tympam during insertion This problem is solved by designing insertion path planning algorithms that provide best fit between the shape of the electrode aunty and the curved scala tympani during insertion Optimality measures that account fittape discrepancies between the steerable electrode array and the scala tympam are used to solve for the optimal path planning of the robot Different arrangements of DoF and insertion speed force feedback (ISFF) are simulated and experimentally validated in this paper A quality of insertion metric describing the gap between the steerable electrode array and the scala tympam model is presented and as correspondence to the insertion force is shown The results of using 1DoF 2DoF and 4DoF electrode array insertion setups are compared The 1DoE insertion setup fiver nonsteerable electrode arrays The 2DoF insertion setup uses single axis insertion with steerable electrode arrays. The 4DoF insertion setup allows full control of the insertion depth and the approach angle of the electrode with respect to the cochlea while using steerable electrode arrays It is shown that living steerable electrode arrays significantly reducer the maximal insertion force (59.6% or more) and effectively prevents buckling of the electrode array The 4DoF Insertion setup further reduces the maximal electrode insertion forces The results of using ISFF for steerable electrodes show a slight decrease in the insertion forcer in contrast to a slight increase for nonsteerable electrodes These results show that further research is required in order to determine the optimal ISFF control law and its effectiveness in reducing electrode invention fortes [DOI 10.1115/1.3039513]
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Modelling and Optimization of the Insertion of a Preformed Cochlear Implant Electrode Array
    Rau, Th S.
    Lenarz, Th
    Majdani, O.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2014, 59 : S1080 - +
  • [42] Direct Feedback during Insertion of the Cochlear Implant Electrode Comment
    Brill, Ioana Tereza
    LARYNGO-RHINO-OTOLOGIE, 2024, 103 (09) : 630 - 630
  • [43] Development of Insertion Models Predicting Cochlear Implant Electrode Position
    van der Marel, Kim S.
    Briaire, Jeroen J.
    Wolterbeek, Ron
    Verbist, Berit M.
    Frijns, Johan H. M.
    EAR AND HEARING, 2016, 37 (04): : 473 - 482
  • [44] Cochlear implant deep electrode insertion: Extent of insertional trauma
    Gstoettner, W
    Plenk, H
    Franz, P
    Hamzavi, J
    Baumgartner, W
    Czerny, C
    Ehrenberger, K
    ACTA OTO-LARYNGOLOGICA, 1997, 117 (02) : 274 - 277
  • [45] Insertion trauma of a cochlear implant electrode array with Nitinol inlay
    Thomas S. Rau
    Lenka Harbach
    Nick Pawsey
    Marcel Kluge
    Peter Erfurt
    Thomas Lenarz
    Omid Majdani
    European Archives of Oto-Rhino-Laryngology, 2016, 273 : 3573 - 3585
  • [46] The Effect of Different Lubricants on Cochlear Implant Electrode Insertion Forces
    Kontorinis, Georgios
    Paasche, Gerrit
    Lenarz, Thomas
    Stoever, Timo
    OTOLOGY & NEUROTOLOGY, 2011, 32 (07) : 1050 - 1056
  • [47] Intracochlear Pressure Transients During Cochlear Implant Electrode Insertion
    Greene, Nathaniel T.
    Mattingly, Jameson K.
    Hartl, Renee M. Banakis
    Tollin, Daniel J.
    Cass, Stephen P.
    OTOLOGY & NEUROTOLOGY, 2016, 37 (10) : 1541 - 1548
  • [48] Automatic Cochlear Duct Length Estimation for Selection of Cochlear Implant Electrode Arrays
    Rivas, Alejandro
    Cakir, Ahmet
    Hunter, Jacob B.
    Labadie, Robert F.
    Zuniga, M. Geraldine
    Wanna, George B.
    Dawant, Benoit M.
    Noble, Jack H.
    OTOLOGY & NEUROTOLOGY, 2017, 38 (03) : 339 - 346
  • [49] 128-multidetector CT: For assessment of optimal depth of electrode array insertion in cochlear implant operations
    Sultan, Amina
    Ghonim, Mohamed Rashad
    Abdelslam, Eman Muhammad
    Abdelaziz, Aya Mohamad
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2018, 49 (03): : 652 - 657
  • [50] Evaluation of Intracochlear Trauma Caused by Insertion of Cochlear Implant Electrode Arrays through Different Quadrants of the Round Window
    Queiroz Martins, Graziela de Souza
    Brito Neto, Rubens Vuono
    Tsuji, Robinson Koji
    Mello Santiago Gebrim, Eloisa Maria
    Bento, Ricardo Ferreira
    BIOMED RESEARCH INTERNATIONAL, 2015, 2015