A simple ensemble strategy of uninformative variable elimination and partial least-squares for near-infrared spectroscopic calibration of pharmaceutical products

被引:22
|
作者
Tan, Chao [1 ,2 ]
Wu, Tong [1 ]
Xu, Zehong [1 ]
Li, Weiyi [1 ]
Zhang, Kaishi [1 ]
机构
[1] Yibin Univ, Dept Chem & Chem Engn, Yibin 644007, Sichuan, Peoples R China
[2] Yibin Univ, Computat Phys Key Lab Sichuan Prov, Yibin 644007, Sichuan, Peoples R China
关键词
Near-infrared; Spectroscopy; Ensemble; Calibration; Uninformative variable elimination; SUBSPACE REGRESSION ENSEMBLE; REFLECTANCE SPECTROSCOPY; WAVELET TRANSFORM; FEASIBILITY; TOBACCO;
D O I
10.1016/j.vibspec.2011.09.011
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Based on uninformative variable elimination (UVE) and partial least squares (PLS), a simple ensemble strategy, named EUVEPLS, is proposed for multivariate calibration of near-infrared spectroscopy. In such a strategy, different calibration sets are first formed by randomly selecting a fixed number of objects from the available calibration data, with replacement, in this manner, different PLS models can be obtained, as in the jackknife procedure. Then, the UVE is used to shrink the original variable space into a specific Subspace, in which a PLS model with the optimal number of latent variables is determined by cross-validation. This process is repeated until a fixed number of candidate models, and therefore the same number of subspaces, are obtained. Finally, those models with better performance are used to produce an ensemble model by simple/weighted average. Two NIR spectral datasets concerning the pharmaceutical products are used to verify the accuracy and robustness of the proposed EUVEPLS. The results confirmed the superiority of EUVEPLS to two single model reference methods (UVEPLS and full-spectrum PLS). (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:44 / 49
页数:6
相关论文
共 50 条
  • [31] Determination of Main Categories of Components in Corn Steep Liquor by Near-Infrared Spectroscopy and Partial Least-Squares Regression
    Xiao, Xue
    Hou, Yuanyuan
    Du, Jun
    Liu, Yang
    Liu, Yanjie
    Dong, Linyi
    Liang, Qionglin
    Wang, Yiming
    Bai, Gang
    Luo, Guoan
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2012, 60 (32) : 7830 - 7835
  • [32] Efficient Near-Infrared Spectroscopic Calibration Methods for Pharmaceutical Blend Monitoring
    Brian M. Zacour
    Benoît Igne
    James K. Drennen
    Carl A. Anderson
    [J]. Journal of Pharmaceutical Innovation, 2011, 6 : 10 - 23
  • [33] Efficient Near-Infrared Spectroscopic Calibration Methods for Pharmaceutical Blend Monitoring
    Zacour, Brian M.
    Igne, Benoit
    Drennen, James K., III
    Anderson, Carl A.
    [J]. JOURNAL OF PHARMACEUTICAL INNOVATION, 2011, 6 (01) : 10 - 23
  • [34] Interval partial least-squares regression (iPLS):: A comparative chemometric study with an example from near-infrared spectroscopy
    Norgaard, L
    Saudland, A
    Wagner, J
    Nielsen, JP
    Munck, L
    Engelsen, SB
    [J]. APPLIED SPECTROSCOPY, 2000, 54 (03) : 413 - 419
  • [35] Partial least squares regression calibration for determining wax content in processed flax fiber by near-infrared spectroscopy
    Sohn, M
    Himmelsbach, DS
    Morrison, WH
    Akin, DE
    Barton, FE
    [J]. APPLIED SPECTROSCOPY, 2006, 60 (04) : 437 - 440
  • [36] Characterization of a Stable Adaptive Calibration Model Using Near-Infrared Spectroscopy and Partial Least Squares with a Kalman Filter
    Mei, Qing-Ping
    Tang, Yi-Ke
    Li, Tai-Fu
    Yao, Li-Zhong
    Yang, Qiong
    Zhang, Heng-Jian
    Liu, Xiao-Hong
    [J]. ANALYTICAL LETTERS, 2018, 51 (08) : 1176 - 1193
  • [37] A method for near-infrared spectral calibration of complex plant samples with wavelet transform and elimination of uninformative variables
    Xueguang Shao
    Fang Wang
    Da Chen
    Qingde Su
    [J]. Analytical and Bioanalytical Chemistry, 2004, 378 : 1382 - 1387
  • [38] Optimisation of partial least squares regression calibration models in near-infrared spectroscopy: a novel algorithm for wavelength selection
    Smith, MR
    Jee, RD
    Moffat, AC
    Rees, DR
    Broad, NW
    [J]. ANALYST, 2003, 128 (11) : 1312 - 1319
  • [39] Combining bootstrap and uninformative variable elimination: Chemometric identification of metabonomic biomarkers by nonparametric analysis of discriminant partial least squares
    Sun, Xiao-Ming
    Yu, Xiao-Ping
    Liu, Yun
    Xu, Lu
    Di, Duo-Long
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2012, 115 : 37 - 43
  • [40] Variable selection using genetic algorithm for analysis of near-infrared spectral data using partial least squares
    Soh, Chit Siang
    Ong, Kok Meng
    Raveendran, P.
    [J]. 2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 1178 - 1181