Rapid and visual detection of 2019 novel coronavirus (SARS-CoV-2) by a reverse transcription loop-mediated isothermal amplification assay

被引:384
|
作者
Yan, C. [1 ]
Cui, J. [1 ]
Huang, L. [2 ]
Du, B. [1 ]
Chen, L. [3 ]
Xue, G. [1 ]
Li, S. [1 ]
Zhang, W. [1 ]
Zhao, L. [1 ]
Sun, Y. [1 ]
Yao, H. [1 ]
Li, N. [1 ]
Zhao, H. [1 ]
Feng, Y. [1 ]
Liu, S. [1 ]
Zhang, Q. [1 ]
Liu, D. [4 ]
Yuan, J. [1 ]
机构
[1] Capital Inst Paediat, Beijing, Peoples R China
[2] Peoples Liberat Army Gen Hosp, Treatment & Res Ctr Infect Dis, Med Ctr 5, Beijing, Peoples R China
[3] Beijing Macro & Microtest Biotech Co Ltd, Beijing, Peoples R China
[4] Chinese Acad Sci, Ctr Bacteria & Virus Resources & Bioinformat, Wuhan Inst Virol, Computat Virol Grp, Wuhan, Peoples R China
基金
中国国家自然科学基金;
关键词
SARS-CoV-2; RT-LAMP; COVID-19; Detection; Visual;
D O I
10.1016/j.cmi.2020.04.001
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Objective: To evaluate a reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay for detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), and compare it with RTPCR. Methods: We designed primers specific to the orf1ab and S genes of SARS-CoV-2. Total viral RNA was extracted using the QIAamp Viral RNA Mini Kit. We optimized the RT-LAMP assay, and evaluated it for its sensitivity and specificity of detection using real-time turbidity monitoring and visual observation. Results: The primer sets orf1ab-4 and S-123 amplified the genes in the shortest times, the mean (+/- SD) times were 18 +/- 1.32 min and 20 +/- 1.80 min, respectively, and 63 degrees C was the optimum reaction temperature. The sensitivities were 2 x 10(1) copies and 2 x 10(2) copies per reaction with primer sets orf1ab-4 and S-123, respectively. This assay showed no cross-reactivity with 60 other respiratory pathogens. To describe the availability of this method in clinical diagnosis, we collected 130 specimens from patients with clinically suspected SARS-CoV-2 infection. Among them, 58 were confirmed to be positive and 72 were negative by RT-LAMP. The sensitivity was 100% (95% CI 92.3%-100%), specificity 100% (95% CI 93.7% e100%). This assay detected SARS-CoV-2 in a mean (+/- SD) time of 26.28 +/- 4.48 min and the results can be identified with visual observation. Conclusion: These results demonstrate that we developed a rapid, simple, specific and sensitive RT-LAMP assay for SARS-CoV-2 detection among clinical samples. It will be a powerful tool for SARS-CoV-2 identification, and for monitoring suspected patients, close contacts and high-risk groups. (C) 2020 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:773 / 779
页数:7
相关论文
共 50 条
  • [1] A Novel Reverse Transcription Loop-Mediated Isothermal Amplification Method for Rapid Detection of SARS-CoV-2
    Lu, Renfei
    Wu, Xiuming
    Wan, Zhenzhou
    Li, Yingxue
    Jin, Xia
    Zhang, Chiyu
    [J]. INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2020, 21 (08)
  • [2] A Sensitive Reverse Transcription Loop-Mediated Isothermal Amplification Assay for Direct Visual Detection of SARS-CoV-2
    Lau, Yee
    Ismail, Ilyiana
    Mustapa, Nur
    Lai, Meng
    Soh, Tuan
    Hassan, Afifah
    Peariasamy, Kalaiarasu
    Lee, Yee
    Goh, Pik
    [J]. AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2020, 103 (06): : 2350 - 2352
  • [3] A Multiplex and Colorimetric Reverse Transcription Loop-Mediated Isothermal Amplification Assay for Sensitive and Rapid Detection of Novel SARS-CoV-2
    Juscamayta-Lopez, Eduardo
    Valdivia, Faviola
    Horna, Helen
    Tarazona, David
    Linares, Liza
    Rojas, Nancy
    Huaringa, Maribel
    [J]. FRONTIERS IN CELLULAR AND INFECTION MICROBIOLOGY, 2021, 11
  • [4] Development of a Novel Reverse Transcription Loop-Mediated Isothermal Amplification Method for Rapid Detection of SARS-CoV-2
    Renfei Lu
    Xiuming Wu
    Zhenzhou Wan
    Yingxue Li
    Lulu Zuo
    Jianru Qin
    Xia Jin
    Chiyu Zhang
    [J]. Virologica Sinica, 2020, (03) : 344 - 347
  • [5] Development of a Novel Reverse Transcription Loop-Mediated Isothermal Amplification Method for Rapid Detection of SARS-CoV-2
    Lu, Renfei
    Wu, Xiuming
    Wan, Zhenzhou
    Li, Yingxue
    Zuo, Lulu
    Qin, Jianru
    Jin, Xia
    Zhang, Chiyu
    [J]. VIROLOGICA SINICA, 2020, 35 (03) : 344 - 347
  • [6] Development of a Novel Reverse Transcription Loop-Mediated Isothermal Amplification Method for Rapid Detection of SARS-CoV-2
    Renfei Lu
    Xiuming Wu
    Zhenzhou Wan
    Yingxue Li
    Lulu Zuo
    Jianru Qin
    Xia Jin
    Chiyu Zhang
    [J]. Virologica Sinica., 2020, 35 (03) - 347
  • [7] Rapid visual detection of SARS-CoV-2 by colorimetric loop-mediated isothermal amplification
    Reynes, Barbara
    Serra, Francisca
    Palou, Andreu
    [J]. BIOTECHNIQUES, 2021, 70 (04) : 218 - 225
  • [8] Real-time reverse transcription loop-mediated isothermal amplification for rapid detection of SARS-CoV-2
    Lau, Yee Ling
    Ismail, Ilyiana
    Mustapa, Nur Izati
    Lai, Meng Yee
    Soh, Tuan Suhaila Tuan
    Hassan, Afifah
    Peariasamy, Kalaiarasu M.
    Lee, Yee Leng
    Chong, Yoong Min
    Sam, I-Ching
    Goh, Pik Pin
    [J]. PEERJ, 2020, 8
  • [9] Colorimetric Reverse Transcription-Loop-Mediated Isothermal Amplification Assay for Rapid Detection of SARS-CoV-2
    Lai, Meng Yee
    Tang, Soo Nee
    Lau, Yee Ling
    [J]. AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2021, 105 (02): : 375 - 377
  • [10] Colorimetric reverse transcriptional loop-mediated isothermal amplification for rapid detection of SARS-CoV-2
    Rai, P.
    Anupama, K. P.
    Pai, A. P.
    Prerana, S.
    Prajna, V. S.
    Ballamoole, K. K.
    Maiti, B.
    [J]. INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2022, 116 : S36 - S36