Rapid and visual detection of 2019 novel coronavirus (SARS-CoV-2) by a reverse transcription loop-mediated isothermal amplification assay

被引:385
|
作者
Yan, C. [1 ]
Cui, J. [1 ]
Huang, L. [2 ]
Du, B. [1 ]
Chen, L. [3 ]
Xue, G. [1 ]
Li, S. [1 ]
Zhang, W. [1 ]
Zhao, L. [1 ]
Sun, Y. [1 ]
Yao, H. [1 ]
Li, N. [1 ]
Zhao, H. [1 ]
Feng, Y. [1 ]
Liu, S. [1 ]
Zhang, Q. [1 ]
Liu, D. [4 ]
Yuan, J. [1 ]
机构
[1] Capital Inst Paediat, Beijing, Peoples R China
[2] Peoples Liberat Army Gen Hosp, Treatment & Res Ctr Infect Dis, Med Ctr 5, Beijing, Peoples R China
[3] Beijing Macro & Microtest Biotech Co Ltd, Beijing, Peoples R China
[4] Chinese Acad Sci, Ctr Bacteria & Virus Resources & Bioinformat, Wuhan Inst Virol, Computat Virol Grp, Wuhan, Peoples R China
基金
中国国家自然科学基金;
关键词
SARS-CoV-2; RT-LAMP; COVID-19; Detection; Visual;
D O I
10.1016/j.cmi.2020.04.001
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Objective: To evaluate a reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay for detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), and compare it with RTPCR. Methods: We designed primers specific to the orf1ab and S genes of SARS-CoV-2. Total viral RNA was extracted using the QIAamp Viral RNA Mini Kit. We optimized the RT-LAMP assay, and evaluated it for its sensitivity and specificity of detection using real-time turbidity monitoring and visual observation. Results: The primer sets orf1ab-4 and S-123 amplified the genes in the shortest times, the mean (+/- SD) times were 18 +/- 1.32 min and 20 +/- 1.80 min, respectively, and 63 degrees C was the optimum reaction temperature. The sensitivities were 2 x 10(1) copies and 2 x 10(2) copies per reaction with primer sets orf1ab-4 and S-123, respectively. This assay showed no cross-reactivity with 60 other respiratory pathogens. To describe the availability of this method in clinical diagnosis, we collected 130 specimens from patients with clinically suspected SARS-CoV-2 infection. Among them, 58 were confirmed to be positive and 72 were negative by RT-LAMP. The sensitivity was 100% (95% CI 92.3%-100%), specificity 100% (95% CI 93.7% e100%). This assay detected SARS-CoV-2 in a mean (+/- SD) time of 26.28 +/- 4.48 min and the results can be identified with visual observation. Conclusion: These results demonstrate that we developed a rapid, simple, specific and sensitive RT-LAMP assay for SARS-CoV-2 detection among clinical samples. It will be a powerful tool for SARS-CoV-2 identification, and for monitoring suspected patients, close contacts and high-risk groups. (C) 2020 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:773 / 779
页数:7
相关论文
共 50 条
  • [41] Novel reverse transcription-multiple inner primer loop-mediated isothermal amplification (RT-MIPLAMP) for visual and sensitive detection of SARS-CoV-2
    He, Xiaofei
    Su, Fengxia
    Chen, Yutong
    Li, Zhengping
    [J]. ANALYTICAL METHODS, 2022, 14 (47) : 5012 - 5018
  • [42] Development of a reverse transcription-loop-mediated isothermal amplification as a rapid early-detection method for novel SARS-CoV-2
    Baek, Yun Hee
    Um, Jihye
    Antigua, Khristine Joy C.
    Park, Ji-Hyun
    Kim, Yeonjae
    Oh, Sol
    Kim, Young-il
    Choi, Won-Suk
    Kim, Seong Gyu
    Jeong, Ju Hwan
    Chin, Bum Sik
    Nicolas, Halcyon Dawn G.
    Ahn, Ji-Young
    Shin, Kyeong Seob
    Choi, Young Ki
    Park, Jun-Sun
    Song, Min-Suk
    [J]. EMERGING MICROBES & INFECTIONS, 2020, 9 (01) : 998 - 1007
  • [43] Development of a reverse transcription loop-mediated isothermal amplification assay for visual detection of avian reovirus
    Xie, Zhixun
    Peng, Yi
    Luo, Sisi
    Wang, Ying
    Liu, Jiabo
    Pang, Yaoshan
    Deng, Xianwen
    Xie, Zhiqin
    Xie, Liji
    Fan, Qing
    Teng, Liqiong
    Wang, Xiuqing
    [J]. AVIAN PATHOLOGY, 2012, 41 (03) : 311 - 316
  • [44] Development of multiplexed reverse-transcription loop-mediated isothermal amplification for detection of SARS-CoV-2 and influenza viral RNA
    Zhang, Yinhua
    Tanner, Nathan A.
    [J]. BIOTECHNIQUES, 2021, 70 (03) : 167 - 174
  • [46] Reverse transcription loop-mediated isothermal amplification assay for rapid detection of Papaya ringspot virus
    Shen, Wentao
    Tuo, Decai
    Yan, Pu
    Yang, Yong
    Li, Xiaoying
    Zhou, Peng
    [J]. JOURNAL OF VIROLOGICAL METHODS, 2014, 204 : 93 - 100
  • [47] A loop-mediated isothermal amplification-enabled analytical assay for the detection of SARS-CoV-2: A review
    Li, Mingna
    Ge, Hongjuan
    Sun, Zhe
    Fu, Jangshan
    Cao, Lele
    Feng, Xinrui
    Meng, Guixian
    Peng, Yubo
    Liu, Yan
    Zhao, Chen
    [J]. FRONTIERS IN CELLULAR AND INFECTION MICROBIOLOGY, 2022, 12
  • [48] Development of Reverse Transcription Loop-Mediated Isothermal Amplification Assays Targeting Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2)
    Park, Gun-Soo
    Ku, Keunbon
    Baek, Seung-Hwa
    Kim, Seong-Jun
    Kim, Seung Il
    Kim, Bum-Tae
    Maeng, Jin-Soo
    [J]. JOURNAL OF MOLECULAR DIAGNOSTICS, 2020, 22 (06): : 729 - 735
  • [49] SIMPLE RNA EXTRACTION METHOD FOR REVERSE TRANSCRIPTION LOOP-MEDIATED AMPLIFICATION DETECTION OF SARS-COV-2
    Zulkefli, Nur Zulaikha
    Bukhari, Fatma Diyana Mohd
    Lai, Meng Yee
    Suppiah, Jeyanthi
    Thayan, Ravindran
    Isa, Mohd Khairi Mat
    Lau, Yee Ling
    [J]. SOUTHEAST ASIAN JOURNAL OF TROPICAL MEDICINE AND PUBLIC HEALTH, 2022, 53 (03) : 345 - 355
  • [50] A triple-target reverse transcription loop-mediated isothermal amplification (RT-LAMP) for rapid and accurate detection of SARS-CoV-2 virus
    Zhang, Cong
    Lv, Ji
    Cao, Yanan
    Yao, Xiaowei
    Yin, Mingzhu
    Li, Shuiqing
    Zheng, Junping
    Liu, Hongtao
    [J]. ANALYTICA CHIMICA ACTA, 2023, 1255