Rapid Injection Linear Dichroism for Studying the Kinetics of Biological Processes

被引:12
|
作者
Hicks, Matthew R. [2 ,3 ]
Rodger, Alison [2 ,3 ]
Lin, Yu-pin [1 ]
Jones, Nykola C. [4 ]
Hoffmann, Soren Vronning [4 ]
Dafforn, Timothy R. [1 ]
机构
[1] Univ Birmingham, Sch Biosci, Birmingham B15 2TT, W Midlands, England
[2] Univ Warwick, Dept Chem, Coventry CV4 7AL, W Midlands, England
[3] Univ Warwick, Warwick Ctr Analyt Sci, Coventry CV4 7AL, W Midlands, England
[4] Aarhus Univ, Inst Storage Ring Facil ISA, Dept Phys & Astron, DK-8000 Aarhus C, Denmark
基金
英国工程与自然科学研究理事会;
关键词
SYNCHROTRON-RADIATION; CONFORMATIONAL-CHANGE; MEMBRANE-INSERTION; DNA-MOLECULES; BOUND GTP; FLOW; ORIENTATION; BINDING;
D O I
10.1021/ac300842h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Linear dichroism is defined as the differential absorbance of linearly polarized light oriented in two orthogonal directions by an aligned sample. The measurement of a linear dichroism (LD) spectrum of a sample provides two key pieces of structural information. First, that the sample and the chromophores within the sample are able to align. Second, given knowledge of the transition polarization directions of the chromophores, the orientation of the chromophores within the aligned sample can be resolved. It has been shown that LD can provide unique information on the structure of some of the more challenging biomolecular complexes. This has included macromolecular protein and peptide fibers such as actin, tubulin, and amyloids as well as protein-membrane complexes and DNA-protein complexes. Much of this work has been enabled by the development of a low volume Couette flow cell that efficiently aligns long molecules in solution. However, the current Couette system is inherently complex to assemble for each experiment and hence not suited to measurement of rapid reactions. In this paper we detail the development of the first rapid injection LD cell. The system utilizes a conventional stopped-flow injection system coupled to a modified low volume Couette cell, where a narrow bore capillary replaces the normal solid central rod. The system is shown to have similar optical characteristics to the conventional LD Couette flow cell but with the added benefit of a much shorter dead time (0.60 s compared to similar to 60). The rapid injection Couette cell has been used to measure the degradation of DNA by DNA exonuclease I, providing data that would not be available using a conventional system.
引用
收藏
页码:6561 / 6566
页数:6
相关论文
共 50 条
  • [31] Peptide Adsorption to Lipid Bilayers: Slow Processes Revealed by Linear Dichroism Spectroscopy
    Ennaceur, Sue M.
    Hicks, Matthew R.
    Pridmore, Catherine J.
    Dafforn, Tim R.
    Rodger, Alison
    Sanderson, John M.
    BIOPHYSICAL JOURNAL, 2009, 96 (04) : 1399 - 1407
  • [32] Use of FTIR spectroscopy for studying the kinetics of solid-state processes
    Tikhomirov, SV
    Arkhangelskii, IV
    Volynskii, AB
    Elyashberg, ME
    JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 52 (08) : 743 - 747
  • [33] USE OF THE ANALOG-NUMBER METHOD IN STUDYING THE KINETICS OF FAST PROCESSES
    AFANASEV, VN
    KRAVCHENKO, OI
    KRESTOV, GA
    ZHURNAL FIZICHESKOI KHIMII, 1983, 57 (03): : 754 - 756
  • [34] On rapid oscillations driving biological processes at disparate timescales
    Lunz, Davin
    PHYSICAL BIOLOGY, 2021, 18 (03)
  • [35] DEVELOPMENT OF TECHNIQUES FOR STUDYING DYE PENETRATION IN RAPID CARPET COLORATION PROCESSES
    BAKKER, PGH
    CRAWSHAW, GH
    INCE, J
    JOURNAL OF THE SOCIETY OF DYERS AND COLOURISTS, 1973, 89 (12): : 486 - 492
  • [36] USE OF MODELS IN STUDYING MACROPHAGE CELL IMAGES AND THE UNDERLYING BIOLOGICAL PROCESSES
    JORDAN, MM
    PERKINS, WJ
    IMAGE AND VISION COMPUTING, 1987, 5 (02) : 139 - 144
  • [37] Molecular imaging with radionuclides, a powerful technique for studying biological processes in vivo
    Cisbani, E.
    Cusanno, F.
    Garibaldi, F.
    Magliozzi, M. L.
    Majewski, S.
    Torrioli, S.
    Tsui, B. M. W.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 571 (1-2): : 169 - 172
  • [38] A MICRO-SIZED GENERIC DEMONSTRATOR FOR STUDYING SYNTHETIC BIOLOGICAL PROCESSES
    Uth, Marc-Florian
    Herwig, Heinz
    PROCEEDINGS IF THE ASME 9TH INTERNATIONAL CONFERENCE ON NANOCHANNELS, MICROCHANNELS AND MINICHANNELS 2011, VOL 1, 2012, : 407 - 413
  • [39] ARTHROPOD MODEL SYSTEMS FOR STUDYING COMPLEX BIOLOGICAL PROCESSES IN THE SPACE ENVIRONMENT
    MARCO, R
    DEJUAN, E
    USHAKOV, I
    HERNANDORENA, A
    GONZALEZJURADO, J
    CALLEJA, M
    MANZANARES, M
    MAROTO, M
    GARESSE, R
    REITZ, G
    MIQUEL, J
    LIFE SCIENCES AND SPACE RESEARCH XXV (1): GRAVITATIONAL BIOLOGY, 1994, 14 (08): : 215 - 227
  • [40] A friendly-Biological Reactor Simulator (BioReSIM) for studying biologial processes in wastewater treatment processes
    Molina Gil, Raul
    Pariente Castillo, Maria Isabel
    Vasiliadou, Ioanna
    Rodriguez Hernandez, Ivan
    Martinez Castillejo, Fernando
    Melero Hernandez, Juan Antonio
    ATTIC-REVISTA D INNOVACIO EDUCATIVA, 2014, (13): : 104 - 113