Automated stent strut coverage and apposition analysis of in-vivo intra coronary Optical Coherence Tomography images

被引:0
|
作者
Ughi, Giovanni J. [1 ]
Adriaenssens, Tom [2 ]
Onsea, Kevin [2 ]
Kayaert, Peter [2 ]
Dubois, Christophe [1 ,2 ]
Coosemans, Mark [2 ]
Sinnaeve, Peter [1 ,2 ]
Desmet, Walter [1 ,2 ]
D'hooge, Jan [1 ]
机构
[1] Catholic Univ Louvain, Dept Cardiovasc Dis, B-3000 Louvain, Belgium
[2] Univ Hosp Leuven, Div Cardiol, Leuven, Belgium
关键词
Optical Coherence Tomography; OCT; intravascular imaging; image processing; lumen segmentation; stent strut segmentation; ACCURACY;
D O I
10.1117/12.874612
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Several studies have proven that intra-vascular OCT is an appropriate imaging modality able to evaluate stent strut apposition and coverage in coronary arteries. Currently image processing is performed manually resulting in a very time consuming and labor intensive procedure. We propose an algorithm for fully automatic individual stent strut apposition and coverage analysis in coronary arteries. The vessel lumen and stent strut are automatically detected and segmented through analysis of the intensity profiles of the A-scan lines. From these data, apposition and coverage can then be estimated automatically. The algorithm was validated using manual measurement (performed by two trained cardiologists) as a reference. 108 images were taken at random from in-vivo pullbacks from 9 different patient presenting 'real-life' situations (i.e. blood residual, small luminal objects and artifacts). High Pearson's correlation coefficients were found (R = 0.96 - 0.95) between the automated and manual measurements while Bland-Altman statistics showed no significant bias with good limits of agreement. As such, it was shown that the presented algorithm provides a robust and a fast tool to automatically estimate apposition and coverage of stent struts in in-vivo pullbacks. This will be important for the integration of this technology in clinical routine and large clinical trials.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Quantitative assessment of the stent/scaffold strut embedment analysis by optical coherence tomography
    Yohei Sotomi
    Hiroki Tateishi
    Pannipa Suwannasom
    Jouke Dijkstra
    Jeroen Eggermont
    Shengnan Liu
    Erhan Tenekecioglu
    Yaping Zheng
    Mohammad Abdelghani
    Rafael Cavalcante
    Robbert J. de Winter
    Joanna J. Wykrzykowska
    Yoshinobu Onuma
    Patrick W. Serruys
    Takeshi Kimura
    [J]. The International Journal of Cardiovascular Imaging, 2016, 32 : 871 - 883
  • [42] Automated Analysis of Directional Optical Coherence Tomography Images
    Rossant, Florence
    Grieve, Kate
    Paques, Michel
    [J]. IMAGE ANALYSIS AND RECOGNITION, ICIAR 2017, 2017, 10317 : 524 - 532
  • [43] Relationship between stent apposition pattern and neointimal coverage after sirolimus-eluting stent implantation: Analysis by optical coherence tomography imaging
    Terashima, M
    Ito, T
    Katoh, O
    Malsubara, T
    Tsuchikane, E
    Ehara, M
    Kinoshita, Y
    Suzuki, T
    Takeda, Y
    Nasu, K
    Surmely, JF
    Tanaka, N
    Murata, A
    Suzuki, T
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (04) : 13B - 13B
  • [44] An Optical Coherence Tomography Assessment of Stent Strut Apposition Based on the Presence of Lipid-Rich Plaque in the Carotid Artery
    Liu, Rui
    Jiang, Yongjun
    Xiong, Yunyun
    Li, Min
    Ma, Minmin
    Zhu, Wusheng
    Yin, Qin
    Li, Wei
    Xu, Gelin
    Liu, Xinfeng
    [J]. JOURNAL OF ENDOVASCULAR THERAPY, 2015, 22 (06) : 942 - 949
  • [45] Early Coverage of Drug Eluting Stents and Bioresorbable Scaffolds Analysed By Optical Coherence Tomography: Evidence of the Impact of Stent Apposition and Strut Characteristic on the Neointimal Healing Process
    Lee, Renick D.
    Foin, Nicolas
    Soh, Nicole
    Ang, Ivy
    Shim, Winston
    Torii, Ryo
    Wong, Philip
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (15) : B180 - B180
  • [46] Automated analysis of fibrous cap in intravascular optical coherence tomography images of coronary arteries
    Lee, Juhwan
    Pereira, Gabriel T. R.
    Gharaibeh, Yazan
    Kolluru, Chaitanya
    Zimin, Vladislav N.
    Dallan, Luis A. P.
    Kim, Justin N.
    Hoori, Ammar
    Al-Kindi, Sadeer G.
    Guagliumi, Giulio
    Bezerra, Hiram G.
    Wilson, David L.
    [J]. SCIENTIFIC REPORTS, 2022, 12 (01):
  • [47] Automated analysis of fibrous cap in intravascular optical coherence tomography images of coronary arteries
    Juhwan Lee
    Gabriel T. R. Pereira
    Yazan Gharaibeh
    Chaitanya Kolluru
    Vladislav N. Zimin
    Luis A. P. Dallan
    Justin N. Kim
    Ammar Hoori
    Sadeer G. Al-Kindi
    Giulio Guagliumi
    Hiram G. Bezerra
    David L. Wilson
    [J]. Scientific Reports, 12 (1)
  • [48] Outcomes of everolimus-eluting stent incomplete stent apposition: a serial optical coherence tomography analysis
    Shimamura, Kunihiro
    Kubo, Takashi
    Akasaka, Takashi
    Kozuma, Ken
    Kimura, Kazuo
    Kawamura, Masaki
    Sumiyoshi, Tetsuya
    Ino, Yasushi
    Yoshiyama, Minoru
    Sonoda, Shinjo
    Igarashi, Keiichi
    Miyazawa, Akiyoshi
    Uzui, Hiroyasu
    Sakanoue, Yuji
    Shinke, Toshiro
    Morino, Yoshihiro
    Tanabe, Kengo
    Kadota, Kazushige
    Kimura, Takeshi
    [J]. EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2015, 16 (01) : 23 - 28
  • [49] OUTCOMES OF EVEROLIMUS-ELUTING STENT INCOMPLETE STENT APPOSITION: A SERIAL OPTICAL COHERENCE TOMOGRAPHY ANALYSIS
    Shimamura, Kunihiro
    Kubo, Takashi
    Akasaka, Takashi
    Kozuma, Ken
    Kimura, Kazuo
    Sumiyoshi, Tetsuya
    Ino, Yasushi
    Yoshiyama, Minoru
    Sonoda, Shinjo
    Igarashi, Keiichi
    Miyazawa, Akiyoshi
    Uzui, Hiroyasu
    Sakanoue, Yuji
    Shinke, Toshiro
    Morino, Yoshihiro
    Tanabe, Kengo
    Kadota, Kazushige
    Kimura, Takeshi
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) : A1794 - A1794
  • [50] Accuracy of measurement of stent strut thickness by optical coherence tomography
    Terashima, Mitsuyasu
    Nakayama, Yoshiaki
    Suzuki, Yasuyoshi
    Katoh, Osamu
    Suzuki, Takahiko
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (10) : B53 - B53