Quantitative assessment of the stent/scaffold strut embedment analysis by optical coherence tomography

被引:0
|
作者
Yohei Sotomi
Hiroki Tateishi
Pannipa Suwannasom
Jouke Dijkstra
Jeroen Eggermont
Shengnan Liu
Erhan Tenekecioglu
Yaping Zheng
Mohammad Abdelghani
Rafael Cavalcante
Robbert J. de Winter
Joanna J. Wykrzykowska
Yoshinobu Onuma
Patrick W. Serruys
Takeshi Kimura
机构
[1] University of Amsterdam,Academic Medical Center
[2] Erasmus Medical Center,ThoraxCenter
[3] Chiang Mai University,Northern Region Heart Center, Faculty of Medicine
[4] Leiden University Medical Center,Division of Image Processing, Department of Radiology
[5] Imperial College London,International Centre for Circulatory Health, NHLI
[6] Kyoto University Hospital,Department of Cardiovascular Medicine
关键词
Strut embedment; Polymeric scaffold; Metallic stent; Reproducibility;
D O I
暂无
中图分类号
学科分类号
摘要
The degree of stent/scaffold embedment could be a surrogate parameter of the vessel wall-stent/scaffold interaction and could have biological implications in the vascular response. We have developed a new specific software for the quantitative evaluation of embedment of struts by optical coherence tomography (OCT). In the present study, we described the algorithm of the embedment analysis and its reproducibility. The degree of embedment was evaluated as the ratio of the embedded part versus the whole strut height and subdivided into quartiles. The agreement and the inter- and intra-observer reproducibility were evaluated using the kappa and the interclass correlation coefficient (ICC). A total of 4 pullbacks of OCT images in 4 randomly selected coronary lesions with 3.0 × 18 mm devices [2 lesions with Absorb BVS and 2 lesions with XIENCE (both from Abbott Vascular, Santa Clara, CA, USA)] from Absorb Japan trial were evaluated by two investigators with QCU-CMS software version 4.69 (Leiden University Medical Center, Leiden, The Netherlands). Finally, 1481 polymeric struts in 174 cross-sections and 1415 metallic struts in 161 cross-sections were analyzed. Inter- and intra-observer reproducibility of quantitative measurements of embedment ratio and categorical assessment of embedment in Absorb BVS and XIENCE had excellent agreement with ICC ranging from 0.958 to 0.999 and kappa ranging from 0.850 to 0.980. The newly developed embedment software showed excellent reproducibility. Computer-assisted embedment analysis could be a feasible tool to assess the strut penetration into the vessel wall that could be a surrogate of acute injury caused by implantation of devices.
引用
收藏
页码:871 / 883
页数:12
相关论文
共 50 条
  • [1] Quantitative assessment of the stent/scaffold strut embedment analysis by optical coherence tomography
    Sotomi, Yohei
    Tateishi, Hiroki
    Suwannasom, Pannipa
    Dijkstra, Jouke
    Eggermont, Jeroen
    Liu, Shengnan
    Tenekecioglu, Erhan
    Zheng, Yaping
    Abdelghani, Mohammad
    Cavalcante, Rafael
    de Winter, Robbert J.
    Wykrzykowska, Joanna J.
    Onuma, Yoshinobu
    Serruys, Patrick W.
    Kimura, Takeshi
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2016, 32 (06): : 871 - 883
  • [2] Quantitative analysis of intracoronary optical coherence tomography measurements of stent strut apposition and tissue coverage
    Barlis, Peter
    Dimopoulos, Konstantinos
    Tanigawa, Jun
    Dzielicka, Ewa
    Ferrante, Giuseppe
    Del Furia, Francesca
    Di Mario, Carlo
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2010, 141 (02) : 151 - 156
  • [3] Stent strut detection in intravascular optical coherence tomography
    Carreira, Maria J.
    Gonzalez, Y. M.
    Penedo, M. G.
    Trillo, R.
    PROCEEDINGS OF THE 2013 8TH IBERIAN CONFERENCE ON INFORMATION SYSTEMS AND TECHNOLOGIES (CISTI 2013), 2013,
  • [4] Reproducibility of quantitative optical coherence tomography for stent analysis
    Gonzalo, Nieves
    Garcia-Garcia, Hector M.
    Serruys, Patrick W.
    Commissaris, Koen H.
    Bezerra, Hiram
    Gobbens, Pierre
    Costa, Marco
    Regar, Evelyn
    EUROINTERVENTION, 2009, 5 (02) : 224 - 232
  • [5] Reproducibility of quantitative optical coherence tomography for stent analysis
    Lopez, N. Gonzalo
    Garcia-Garcia, H. M.
    Serruys, P. W.
    Commissaris, K.
    Bezerra, H.
    Gobbens, P.
    Costa, M.
    Regar, E.
    EUROPEAN HEART JOURNAL, 2009, 30 : 675 - 675
  • [6] Reproducibility Of Quantitative Optical Coherence Tomography For Stent Analysis
    Gonzalo, Nieves
    Garcia-Garcia, Hector M.
    Serruys, Patrick W.
    Commissaris, Koen H.
    Bezerra, Hiram
    Gobbens, Pierre
    Costa, Marco
    Regar, Evelyn
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (6A): : 55D - 56D
  • [7] Accuracy of measurement of stent strut thickness by optical coherence tomography
    Terashima, Mitsuyasu
    Nakayama, Yoshiaki
    Suzuki, Yasuyoshi
    Katoh, Osamu
    Suzuki, Takahiko
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (10) : B53 - B53
  • [8] Accuracy of measurement of stent strut thickness by optical coherence tomography
    Terashima, M.
    Nakayama, Y.
    Suzuki, Y.
    Habara, M.
    Katoh, O.
    Suzuki, T.
    EUROPEAN HEART JOURNAL, 2008, 29 : 684 - 684
  • [9] Optical coherence tomography assessment of strut coverage of a fully biodegradable Everolimus-eluting stent
    Kukreja, N.
    Regar, E.
    De Winter, S.
    Bruining, N.
    Sianos, G.
    Serruys, P. W.
    EUROPEAN HEART JOURNAL, 2007, 28 : 263 - 263
  • [10] Automated measurement of stent strut coverage in intravascular optical coherence tomography
    Chi Young Ahn
    Byeong-Keuk Kim
    Myeong-Ki Hong
    Yangsoo Jang
    Jung Heo
    Chulmin Joo
    Jin Keun Seo
    Journal of the Korean Physical Society, 2015, 66 : 558 - 570