Quantitative assessment of the stent/scaffold strut embedment analysis by optical coherence tomography

被引:0
|
作者
Yohei Sotomi
Hiroki Tateishi
Pannipa Suwannasom
Jouke Dijkstra
Jeroen Eggermont
Shengnan Liu
Erhan Tenekecioglu
Yaping Zheng
Mohammad Abdelghani
Rafael Cavalcante
Robbert J. de Winter
Joanna J. Wykrzykowska
Yoshinobu Onuma
Patrick W. Serruys
Takeshi Kimura
机构
[1] University of Amsterdam,Academic Medical Center
[2] Erasmus Medical Center,ThoraxCenter
[3] Chiang Mai University,Northern Region Heart Center, Faculty of Medicine
[4] Leiden University Medical Center,Division of Image Processing, Department of Radiology
[5] Imperial College London,International Centre for Circulatory Health, NHLI
[6] Kyoto University Hospital,Department of Cardiovascular Medicine
来源
The International Journal of Cardiovascular Imaging | 2016年 / 32卷
关键词
Strut embedment; Polymeric scaffold; Metallic stent; Reproducibility;
D O I
暂无
中图分类号
学科分类号
摘要
The degree of stent/scaffold embedment could be a surrogate parameter of the vessel wall-stent/scaffold interaction and could have biological implications in the vascular response. We have developed a new specific software for the quantitative evaluation of embedment of struts by optical coherence tomography (OCT). In the present study, we described the algorithm of the embedment analysis and its reproducibility. The degree of embedment was evaluated as the ratio of the embedded part versus the whole strut height and subdivided into quartiles. The agreement and the inter- and intra-observer reproducibility were evaluated using the kappa and the interclass correlation coefficient (ICC). A total of 4 pullbacks of OCT images in 4 randomly selected coronary lesions with 3.0 × 18 mm devices [2 lesions with Absorb BVS and 2 lesions with XIENCE (both from Abbott Vascular, Santa Clara, CA, USA)] from Absorb Japan trial were evaluated by two investigators with QCU-CMS software version 4.69 (Leiden University Medical Center, Leiden, The Netherlands). Finally, 1481 polymeric struts in 174 cross-sections and 1415 metallic struts in 161 cross-sections were analyzed. Inter- and intra-observer reproducibility of quantitative measurements of embedment ratio and categorical assessment of embedment in Absorb BVS and XIENCE had excellent agreement with ICC ranging from 0.958 to 0.999 and kappa ranging from 0.850 to 0.980. The newly developed embedment software showed excellent reproducibility. Computer-assisted embedment analysis could be a feasible tool to assess the strut penetration into the vessel wall that could be a surrogate of acute injury caused by implantation of devices.
引用
收藏
页码:871 / 883
页数:12
相关论文
共 50 条
  • [21] Strut apposition after coronary stent implantation visualised with optical coherence tomography
    Radu, Maria
    Jorgensen, Erik
    Kelbaek, Henning
    Helqvist, Steffen
    Skovgaard, Lene
    Saunamaki, Karl
    EUROINTERVENTION, 2010, 6 (01) : 86 - 93
  • [22] Stent Strut Apposition in Coronary Bifurcation Lesions assessed with Optical Coherence Tomography
    Ferrante, Giuseppe
    Ramasami, Nandakumar
    Tyczynski, Pawel
    Kukreja, Neville
    Aguiar-Souto, Pablo
    Del Furia, Francesca
    Barlis, Peter
    Beatt, Kevin
    Di Mario, Carlo
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (10) : A78 - A78
  • [23] Quantitative Optical Coherence Tomography Analysis for Late In-Stent Restenotic Lesions
    Fu, Qiang
    Suzuki, Nobuaki
    Kozuma, Ken
    Miyagawa, Mutsuld
    Nomura, Takahiro
    Kawashima, Hideyuki
    Shiratori, Yoshitaka
    Ishikawa, Shuichi
    Kyono, Hiroyuki
    Isshiki, Takaaki
    INTERNATIONAL HEART JOURNAL, 2015, 56 (01) : 13 - 17
  • [24] Quantitative optical coherence tomography signal analysis for in-stent restenotic tissue
    Suzuki, N.
    Kozuma, K.
    Saito, T.
    Hosogoe, N.
    Naito, K.
    Otsuki, S.
    Ishikawa, S.
    Kyono, H.
    Miyazawa, A.
    Isshiki, T.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2011, 183 : 746 - 746
  • [25] Quantitative optical coherence tomography signal analysis for in-stent restenotic tissue
    Suzuki, N.
    Kozuma, K.
    Saito, T.
    Hosogoe, N.
    Naito, K.
    Otsuki, S.
    Ishikawa, S.
    Kyono, H.
    Miyazawa, A.
    Isshiki, T.
    EUROPEAN HEART JOURNAL, 2011, 32 : 746 - 746
  • [26] The role of optical coherence tomography guidance in scaffold versus stent optimization
    Al Nooryani, Arif A.
    Abdelrahman, Nagwa A.
    Helmy, Hatem A.
    Kishk, Yehia T.
    Hassan, Ayman K. M.
    EGYPTIAN HEART JOURNAL, 2020, 72 (01):
  • [27] The role of optical coherence tomography guidance in scaffold versus stent optimization
    Arif A. Al Nooryani
    Nagwa A. Abdelrahman
    Hatem A. Helmy
    Yehia T. Kishk
    Ayman K. M. Hassan
    The Egyptian Heart Journal, 72
  • [28] Role of Optical Coherence Tomography in the Assessment of Stent Deformation
    Abdel-Hadi, Hani
    Shah, Ashish H.
    Dzavik, Vladimir
    CANADIAN JOURNAL OF CARDIOLOGY, 2016, 32 (03) : 396.e1 - 396.e2
  • [29] Optical coherence tomography assessment of early stent strut coverage in patients treated with a thin-strut bare cobalt-chromium stent coated with silicon carbide
    Samim, Mariam
    Agostoni, Pierfrancesco
    Voskuil, Michiel
    Belkacemi, Anouar
    Doevendans, Pieter A.
    Stella, Pieter R.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2012, 157 (02) : 291 - 292
  • [30] Strut Level Optical Coherence Tomography Evaluation of Coronary Stent Strut Coverage Temporal Trends: A Systematic Review
    Lee, Kwan S.
    Lee, Justin Z.
    Riaz, Irbaz B.
    Husnain, Muhammad
    Riaz, Haris
    Lotun, Kapil
    Kern, Karl B.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 62 (18) : B255 - B256