Computed diffusion-weighted MRI for prostate cancer detection: the influence of the combinations of b-values

被引:29
|
作者
Ueno, Y. [1 ]
Takahashi, S. [1 ]
Ohno, Y. [1 ,2 ]
Kitajima, K. [1 ]
Yui, M. [3 ]
Kassai, Y. [3 ]
Kawakami, F. [4 ]
Miyake, H. [5 ]
Sugimura, K. [1 ]
机构
[1] Kobe Univ, Grad Sch Med, Dept Radiol, Kobe, Hyogo 657, Japan
[2] Kobe Univ, Grad Sch Med, Adv Biomed Imaging Res, Kobe, Hyogo 657, Japan
[3] Toshiba Med Syst Corp, Otawara, Tochigi, Japan
[4] Kobe Univ, Grad Sch Med, Dept Pathol, Kobe, Hyogo 657, Japan
[5] Kobe Univ, Grad Sch Med, Dept Urol, Kobe, Hyogo 657, Japan
来源
BRITISH JOURNAL OF RADIOLOGY | 2015年 / 88卷 / 1048期
关键词
BODY; LOCALIZATION; CHALLENGES; PET/CT;
D O I
10.1259/bjr.20140738
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To evaluate the influence of the combinations of b-values on computed diffusion-weighted images (cDWIs) for prostate cancer (PCa) detection at b=2000 smm(-2). Methods: Diffusion-weighted imaging (DWIs) for 31 patients with PCa (65.2 +/- 7.1 years) were obtained pre-operatively at different b-values (0, 100, 500, 1000 and 2000 s mm(-2)) on a 3-T MRI. cDWIs at b=2000 were generated by using six b-value combinations: 0-100 s mm(-2) (cDWI(0-100)); 0-500 smm(-2) (cDWI(0-500)); 100-500 s mm(-2) (cDWI(100-500)); 0-1000 s mm(-2) (cDWI(0-1000)); 100-1000 s mm(-2) (cDWI(100-1000)); and 500-1000 s mm(-2) (cDWI(500-1000)). These cDWIs and measured DWIs with b=2000 s mm(-2) (mDWI(2000)) were evaluated in this setting. To assess image quality for each DWI, contrast ratios (CRs) of cancerous and non-cancerous lesions were evaluated. To compare the detectability of PCa for each DWI, receiver operating characteristic analysis was used. Results: CRs of all cDWIs were significantly higher than those of mDWI(2000) (p < 0.05). Areas under the curve of cDWI(0-100) (0.62) and cDWI(0-500) (0.65) were significantly smaller (p < 0.05) than those of others (cDWI(100-500), 0.72; cDWI(0-1000), 0.73; cDWI(100-1000), 0.71; cDWI(500-1000), 0.74; mDWI(2000), 0.72). Conclusion: The combinations of b-values influenced image quality and diagnostic ability of cDWIs for PCa detection. The combinations of b >= 100 and b >= 500 s mm(-2), as well as b=0 and b=1000 s mm(-2), were optimal in this study. Advances in knowledge: For generating the useful cDWI for PCa detection, radiologists should take care of the combination of b-values when including low b-values.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Diffusion MRI of cancer: From low to high b-values
    Tang, Lei
    Zhou, Xiaohong Joe
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 49 (01) : 23 - 40
  • [32] Intravoxel Incoherent Motion Diffusion-Weighted Magnetic Resonance Imaging of Cervical Cancer With Different b-Values
    Wu, Qingxia
    Wang, Yan
    Shi, Ligang
    Dong, Li
    Liu, Mingbo
    Dou, Shewei
    Zhu, Shaocheng
    Wang, Meiyun
    Shi, Dapeng
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2017, 41 (04) : 592 - 598
  • [33] Comparison of synthesized and acquired high b-value diffusion-weighted MRI for detection of prostate cancer
    Kallis, Karoline
    Conlin, Christopher C.
    Zhong, Allison Y.
    Hussain, Troy S.
    Chatterjee, Aritrick
    Karczmar, Gregory S.
    Rakow-Penner, Rebecca
    Dale, Anders M.
    Seibert, Tyler M.
    CANCER IMAGING, 2024, 24 (01)
  • [34] Diffusion-weighted imaging: determination of the best pair of b-values to discriminate breast lesions
    Nogueira, L.
    Brandao, S.
    Matos, E.
    Nunes, R. G.
    Loureiro, J.
    Ferreira, H. A.
    Ramos, I.
    BRITISH JOURNAL OF RADIOLOGY, 2014, 87 (1039):
  • [35] Diffusion-weighted signal models in healthy and cancerous peripheral prostate tissues: Comparison of outcomes obtained at different b-values
    Mazzoni, Lorenzo N.
    Lucarini, Silvia
    Chiti, Stefano
    Busoni, Simone
    Gori, Cesare
    Menchi, Ilario
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (03) : 512 - 518
  • [36] Hybrid Multidimensional T2 and Diffusion-Weighted MRI for Prostate Cancer Detection
    Wang, Shiyang
    Peng, Yahui
    Medved, Milica
    Yousuf, Ambereen N.
    Ivancevic, Marko K.
    Karademir, Ibrahim
    Jiang, Yulei
    Antic, Tatjana
    Sammet, Steffen
    Oto, Aytekin
    Karczmar, Gregory S.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (04) : 781 - 788
  • [37] Diffusion-Weighted MRI as a Predictor of Extracapsular Extension in Prostate Cancer
    Kim, Chan Kyo
    Park, Sung Yoon
    Park, Jung Jae
    Park, Byung Kwan
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 202 (03) : W270 - W276
  • [38] The emerging role of diffusion-weighted MRI in prostate cancer management
    Lawrence, Edward M.
    Gnanapragasam, Vincent J.
    Priest, Andrew N.
    Sala, Evis
    NATURE REVIEWS UROLOGY, 2012, 9 (02) : 94 - 101
  • [39] Diffusion-Weighted MRI at 3 T for the Evaluation of Prostate Cancer
    Kim, Chan Kyo
    Park, Byung Kwan
    Kim, Bohyun
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (06) : 1461 - 1469
  • [40] Accuracy of high b-value diffusion-weighted MRI for prostate cancer detection: a meta-analysis
    Godley, Keith Craig
    Syer, Tom Joseph
    Toms, Andoni Paul
    Smith, Toby Oliver
    Johnson, Glyn
    Cameron, Donnie
    Malcolm, Paul Napier
    ACTA RADIOLOGICA, 2018, 59 (01) : 105 - 113