Comparison of synthesized and acquired high b-value diffusion-weighted MRI for detection of prostate cancer

被引:0
|
作者
Kallis, Karoline [2 ]
Conlin, Christopher C. [1 ]
Zhong, Allison Y. [2 ]
Hussain, Troy S. [2 ]
Chatterjee, Aritrick [6 ,7 ]
Karczmar, Gregory S. [6 ,7 ]
Rakow-Penner, Rebecca [1 ]
Dale, Anders M. [1 ,3 ,4 ]
Seibert, Tyler M. [1 ,2 ,5 ]
机构
[1] Univ Calif San Diego Hlth, Dept Radiol, San Diego, CA 92093 USA
[2] Univ Calif San Diego Hlth, Dept Radiat Med & Appl Sci, La Jolla, CA 92093 USA
[3] Univ Calif San Diego Hlth, Dept Neurosci, San Diego, CA USA
[4] Univ Calif San Diego, Halicioglu Data Sci Inst, San Diego, CA USA
[5] Univ Calif San Diego, Jacobs Sch Engn, Dept Bioengn, San Diego, CA 92093 USA
[6] Univ Chicago, Dept Radiol, Chicago, IL USA
[7] Univ Chicago, Sanford J Grossmann Ctr Excellence Prostate Imagin, Chicago, IL USA
基金
美国国家卫生研究院;
关键词
Diffusion-weighted imaging; Prostate cancer; Synthetic high b-values; Restricted Spectrum Imaging; FEASIBILITY; DIAGNOSIS; PERFUSION; IMAGES; TISSUE; DWI;
D O I
10.1186/s40644-024-00723-6
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background High b-value diffusion-weighted images (DWI) are used for detection of clinically significant prostate cancer (csPCa). This study qualitatively and quantitatively compares synthesized DWI (sDWI) to acquired (aDWI) for detection of csPCa. Methods One hundred fifty-one consecutive patients who underwent prostate MRI and biopsy were included in the study. Axial DWI with b = 0, 500, 1000, and 2000 s/mm(2) using a 3T clinical scanner using a 32-channel phased-array body coil were acquired. We retrospectively synthesized DWI for b = 2000 s/mm(2) via extrapolation based on mono-exponential decay, using b = 0 and b = 500 s/mm(2) (sDWI(500)) and b = 0, b = 500 s/mm(2), and b = 1000 s/mm(2) (sDWI(1000)). Differences in signal intensity between sDWI and aDWI were evaluated within different regions of interest (prostate alone, prostate plus 5 mm, 30 mm and 70 mm margin and full field of view). The maximum DWI value within each ROI was evaluated for prediction of csPCa. Classification accuracy was compared to Restriction Spectrum Imaging restriction score (RSIrs), a previously validated biomarker based on multi-exponential DWI. Discrimination of csPCa was evaluated via area under the receiver operating characteristic curve (AUC). Results Within the prostate, mean +/- standard deviation of percent mean differences between sDWI and aDWI signal were -46 +/- 35% for sDWI(1000) and -67 +/- 24% for sDWI(500). AUC for aDWI, sDWI(500,) sDWI(1000), and RSIrs within the prostate 0.62[95% confidence interval: 0.53, 0.71], 0.63[0.54, 0.72], 0.65[0.56, 0.73] and 0.78[0.71, 0.86], respectively. Conclusions DWI is qualitatively comparable to aDWI within the prostate. However, hyperintense artifacts are introduced with sDWI in the surrounding pelvic tissue that interfere with quantitative cancer detection and might mask metastases. In the prostate, RSIrs yields superior quantitative csPCa detection than sDWI or aDWI.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Model selection for high b-value diffusion-weighted MRI of the prostate
    Mazaheri, Yousef
    Hotker, Andreas M.
    Shukla-Dave, Amita
    Akin, Oguz
    Hricak, Hedvig
    MAGNETIC RESONANCE IMAGING, 2018, 46 : 21 - 27
  • [2] Accuracy of high b-value diffusion-weighted MRI for prostate cancer detection: a meta-analysis
    Godley, Keith Craig
    Syer, Tom Joseph
    Toms, Andoni Paul
    Smith, Toby Oliver
    Johnson, Glyn
    Cameron, Donnie
    Malcolm, Paul Napier
    ACTA RADIOLOGICA, 2018, 59 (01) : 105 - 113
  • [3] Breast Cancer Conspicuity on Computed Versus Acquired High b-Value Diffusion-Weighted MRI
    DelPriore, Michaela R.
    Biswas, Debosmita
    Hippe, Daniel S.
    Zecevic, Mladen
    Parsian, Sana
    Scheel, John R.
    Rahbar, Habib
    Partridge, Savannah C.
    ACADEMIC RADIOLOGY, 2021, 28 (08) : 1108 - 1117
  • [4] Ultra-high b-value diffusion-weighted MRI for the detection of prostate cancer with 3-T MRI
    Ueno, Yoshiko
    Kitajima, Kazuhiro
    Sugimura, Kazuro
    Kawakami, Fumi
    Miyake, Hideaki
    Obara, Makoto
    Takahashi, Satoru
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 38 (01) : 154 - 160
  • [5] Synthetic Apparent Diffusion Coefficient for High b-Value Diffusion-Weighted MRI in Prostate
    Sahoo, Prativa
    Rockne, Russell C.
    Jung, Alexander
    Gupta, Pradeep K.
    Rathore, Ram K. S.
    Gupta, Rakesh K.
    PROSTATE CANCER, 2020, 2020
  • [6] Evaluation of the impact of computed high b-value diffusion-weighted imaging on prostate cancer detection
    Sadhna Verma
    Saradwata Sarkar
    Jason Young
    Rajesh Venkataraman
    Xu Yang
    Anil Bhavsar
    Nilesh Patil
    James Donovan
    Krishnanath Gaitonde
    Abdominal Radiology, 2016, 41 : 934 - 945
  • [7] Comparison of calculated and acquired high b value diffusion-weighted imaging in prostate cancer
    Grant, Kinzya B.
    Agarwal, Harsh K.
    Shih, Joanna H.
    Bernardo, Marcelino
    Pang, Yuxi
    Daar, Dagane
    Merino, Maria J.
    Wood, Bradford J.
    Pinto, Peter A.
    Choyke, Peter L.
    Turkbey, Baris
    ABDOMINAL IMAGING, 2015, 40 (03): : 578 - 586
  • [8] Evaluation of the impact of computed high b-value diffusion-weighted imaging on prostate cancer detection
    Verma, Sadhna
    Sarkar, Saradwata
    Young, Jason
    Venkataraman, Rajesh
    Yang, Xu
    Bhavsar, Anil
    Patil, Nilesh
    Donovan, James
    Gaitonde, Krishnanath
    ABDOMINAL RADIOLOGY, 2016, 41 (05) : 934 - 945
  • [9] Comparison of calculated and acquired high b value diffusion-weighted imaging in prostate cancer
    Kinzya B. Grant
    Harsh K. Agarwal
    Joanna H. Shih
    Marcelino Bernardo
    Yuxi Pang
    Dagane Daar
    Maria J. Merino
    Bradford J. Wood
    Peter A. Pinto
    Peter L. Choyke
    Baris Turkbey
    Abdominal Imaging, 2015, 40 : 578 - 586
  • [10] High b-value diffusion-weighted MRI of normal brain
    Burdette, JH
    Durden, DD
    Elster, AD
    Yen, YF
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2001, 25 (04) : 515 - 519