Post-gadolinium evaluation of intracranial tumours: a comparative study of Spin Echo, Fast Spin Echo, Gradient Echo T1-weighted sequences, with and without Magnetization Transfer

被引:0
|
作者
Aprile, I
Lavaroni, A
Scott, CA
Budai, R
Beltrami, CA
Fabris, G
机构
[1] S Maria della Misericordia Gen Hosp, Dept Neuroradiol, Udine, Italy
[2] Univ Udine, Inst Pathol, I-33100 Udine, Italy
[3] S Maria della Misericordia Gen Hosp, Dept Neurol Clin Neurophysiol, Udine, Italy
来源
RIVISTA DI NEURORADIOLOGIA | 2001年 / 14卷 / 03期
关键词
brain tumours; magnetic resonance; comparative studies; magnetization transfer contrast;
D O I
10.1177/197140090101400303
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
This study compares the use of six different post-gadolinium T1-weighted sequences on intracranial tumours with the aim of evaluating their efficacy in terms of lesion and edema contrast resolution and cortex visualization. Forty-eight intracranial neoplastic lesions were evaluated after contrast media administration by means of the following Tl-weighted sequences: Fast Spin-Echo (FSE), Spin-Echo (SE) and Gradient-Echo (GE) with and without Magnetization Transfer (MT) pulse. For each technique tumour/background contrast resolution (T/B CR), oedema/background contrast resolution (E/B CR) and white matter/grey matter contrast resolution (WM/GM CR) were calculated. GE sequences, with and without MT, showed the lowest contrast resolution values for all parameters. FSE MT sequences showed the highest T/B CR values. SE sequences, instead, showed the best E/B and WM/GM CR values. FSE and SE MT values were intermediate between FSE MT and SE sequences. No sequence had high values for all contrast resolution parameters. The sequence with the best T/B CR was the FSE MT, but that with the best anatomic peritumoural edema and cortex definition was SE. Both FSE MT and SE T1-weighted sequences may be acquired to obtain accurate post-gadolinium tumour evaluation.
引用
收藏
页码:259 / 265
页数:7
相关论文
共 50 条
  • [41] STAGING URINARY-BLADDER CANCER - VALUE OF T1-WEIGHTED 3-DIMENSIONAL MAGNETIZATION PREPARED-RAPID GRADIENT-ECHO AND 2-DIMENSIONAL SPIN-ECHO SEQUENCES
    BARENTSZ, JO
    JAGER, G
    MUGLER, JP
    OOSTERHOF, G
    PETERS, H
    VANERNING, LTJO
    RUIJS, SHJ
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 164 (01) : 109 - 115
  • [42] PROSPECTIVE COMPARISON OF T2-WEIGHTED FAST SPIN-ECHO, WITH AND WITHOUT FAT-SUPPRESSION, AND CONVENTIONAL SPIN-ECHO PULSE SEQUENCES IN THE UPPER ABDOMEN
    SCHWARTZ, LH
    SELTZER, SE
    TEMPANY, CMC
    SILVERMAN, SG
    PIWNICAWORMS, DR
    ADAMS, DF
    HERMAN, L
    HERMAN, LT
    HOOSHMAND, R
    RADIOLOGY, 1993, 189 (02) : 411 - 416
  • [43] Comparison of single-echo T2-weighted fast spin-echo and conventional spin-echo MR sequences - In the detection of brain lesions of multiple sclerosis
    Sparacia, G
    Angileri, T
    Banco, A
    Miraglia, R
    Nicastro, T
    Lagalla, R
    RIVISTA DI NEURORADIOLOGIA, 1998, 11 (04): : 471 - 476
  • [44] CONTRAST ON T2-WEIGHTED IMAGES OF THE LUMBAR SPINE USING FAST SPIN-ECHO AND GATED CONVENTIONAL SPIN-ECHO SEQUENCES
    CHAPPELL, PM
    GLOVER, GH
    ENZMANN, DR
    NEURORADIOLOGY, 1995, 37 (03) : 183 - 186
  • [45] Comparison of T2-weighted fast spin-echo and spin-echo MR sequences in the detection of brain lesions of multiple sclerosis
    Sparacia, G
    Angileri, T
    Accardi, M
    Pappalardo, S
    Sarno, C
    DeMaria, M
    RIVISTA DI NEURORADIOLOGIA, 1997, 10 : 233 - 235
  • [46] Bone Marrow Metastases: T2-weighted Dixon Spin-Echo Fat Images Can Replace T1-weighted Spin-Echo Images
    Maeder, Yael
    Dunet, Vincent
    Richard, Raphael
    Becce, Fabio
    Omoumi, Patrick
    RADIOLOGY, 2018, 286 (03) : 853 - 864
  • [47] Analysis of magnetization transfer effects on T1-weighted spin-echo scans using a simple tissue phantom simulating gadolinium-enhanced brain lesions
    Finelli, DA
    Hurst, GC
    Frank, HA
    Gullapali, RP
    Apicella, A
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (04): : 731 - 738
  • [48] SPONTANEOUS NECROSIS OF THE FEMORAL CONDYLUS - NOVEL FINDINGS IN T2-WEIGHTED SPIN-ECHO SEQUENCES AND GRADIENT ECHO STUDIES
    BOOTSVELD, K
    SIEWERT, B
    REISER, M
    KOCH, W
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1992, 156 (04): : 360 - 364
  • [49] COMPARISON OF GRADIENT-RECALLED-ECHO AND T2-WEIGHTED SPIN-ECHO PULSE SEQUENCES IN INTRAMEDULLARY SPINAL LESIONS
    KATZ, BH
    QUENCER, RM
    HINKS, RS
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1989, 10 (04) : 815 - 822
  • [50] Fat suppression imaging in neuroradiology with T2 weighted fast spin echo sequences
    Scarabino, T
    Giannatempo, GM
    Simeone, A
    Perfetto, F
    Popolizio, T
    Polonara, G
    Salvolini, U
    RIVISTA DI NEURORADIOLOGIA, 1996, 9 (02): : 157 - 164