Post-gadolinium evaluation of intracranial tumours: a comparative study of Spin Echo, Fast Spin Echo, Gradient Echo T1-weighted sequences, with and without Magnetization Transfer

被引:0
|
作者
Aprile, I
Lavaroni, A
Scott, CA
Budai, R
Beltrami, CA
Fabris, G
机构
[1] S Maria della Misericordia Gen Hosp, Dept Neuroradiol, Udine, Italy
[2] Univ Udine, Inst Pathol, I-33100 Udine, Italy
[3] S Maria della Misericordia Gen Hosp, Dept Neurol Clin Neurophysiol, Udine, Italy
来源
RIVISTA DI NEURORADIOLOGIA | 2001年 / 14卷 / 03期
关键词
brain tumours; magnetic resonance; comparative studies; magnetization transfer contrast;
D O I
10.1177/197140090101400303
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
This study compares the use of six different post-gadolinium T1-weighted sequences on intracranial tumours with the aim of evaluating their efficacy in terms of lesion and edema contrast resolution and cortex visualization. Forty-eight intracranial neoplastic lesions were evaluated after contrast media administration by means of the following Tl-weighted sequences: Fast Spin-Echo (FSE), Spin-Echo (SE) and Gradient-Echo (GE) with and without Magnetization Transfer (MT) pulse. For each technique tumour/background contrast resolution (T/B CR), oedema/background contrast resolution (E/B CR) and white matter/grey matter contrast resolution (WM/GM CR) were calculated. GE sequences, with and without MT, showed the lowest contrast resolution values for all parameters. FSE MT sequences showed the highest T/B CR values. SE sequences, instead, showed the best E/B and WM/GM CR values. FSE and SE MT values were intermediate between FSE MT and SE sequences. No sequence had high values for all contrast resolution parameters. The sequence with the best T/B CR was the FSE MT, but that with the best anatomic peritumoural edema and cortex definition was SE. Both FSE MT and SE T1-weighted sequences may be acquired to obtain accurate post-gadolinium tumour evaluation.
引用
收藏
页码:259 / 265
页数:7
相关论文
共 50 条
  • [21] Comparison of T1-weighted Spin-Echo and 3D T1-weighted multishot echo planar pulse sequences in imaging the brain at 1T
    Karantanas, AH
    Papanikolaou, N
    Vasiou, K
    Lavdas, E
    MAGNETIC RESONANCE IMAGING, 1999, 17 (05) : 663 - 668
  • [22] MR EVALUATION OF VERTEBRAL METASTASES - T1-WEIGHTED, SHORT-INVERSION-TIME INVERSION-RECOVERY, FAST SPIN-ECHO, AND INVERSION-RECOVERY FAST SPIN-ECHO SEQUENCES
    MEHTA, RC
    MARKS, MP
    HINKS, RS
    GLOVER, GH
    ENZMANN, DR
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1995, 16 (02) : 281 - 288
  • [23] Optimal MR protocol for hepatic hemangiomas - Comparison of conventional spin-echo sequences with T2-weighted turbo spin-echo and serial gradient-echo (FLASH) sequences with gadolinium enhancement
    Kim, TK
    Choi, BI
    Han, JK
    Jang, HJ
    Han, MC
    ACTA RADIOLOGICA, 1997, 38 (04) : 565 - 571
  • [24] Analysis of artefacts and detail resolution of lung MRI with breath-hold T1-weighted gradient-echo and T2-weighted fast spin-echo sequences with respiratory triggering
    Biederer, J
    Reuter, M
    Both, M
    Muhle, C
    Grimm, J
    Graessner, J
    Heller, M
    EUROPEAN RADIOLOGY, 2002, 12 (02) : 378 - 384
  • [25] Analysis of artefacts and detail resolution of lung MRI with breath-hold T1-weighted gradient-echo and T2-weighted fast spin-echo sequences with respiratory triggering
    J. Biederer
    M. Reuter
    M. Both
    C. Muhle
    J. Grimm
    J. Graessner
    M. Heller
    European Radiology, 2002, 12 : 378 - 384
  • [26] MR dynamic Gadolinium-enhanced fast multiplanar spoiled gradient-echo and spin-echo T1-weighted fat-suppressed techniques in diagnosis of pancreatic carcinoma
    Meng-Su Zeng
    Fu-Hua Yan
    Kang-Rong Zhou
    Zhu-Wan Chen
    Ji-Zhang Sun
    Cai-Zhong Chen
    Wei-Bing Shi From the Dapartment of Radiology
    Hepatobiliary&PancreaticDiseasesInternational, 2002, (02) : 294 - 298
  • [27] T2-weighted MR imaging of the uterus: Comparison of optimized fast spin-echo and HASTE sequences with conventional fast spin-echo sequences
    Gryspeerdt, S
    Van Hoe, L
    Bosmans, H
    Baert, AL
    Vergote, I
    Marchal, G
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (01) : 211 - 215
  • [28] Correction of intensity nonuniformity in spin-echo T1-weighted images
    Collewet, G
    Davenel, A
    Toussaint, C
    Akoka, S
    MAGNETIC RESONANCE IMAGING, 2002, 20 (04) : 365 - 373
  • [29] T2-WEIGHTED MR-IMAGING OF THE ABDOMEN - FAST SPIN-ECHO VS CONVENTIONAL SPIN-ECHO SEQUENCES
    CATASCA, JV
    MIROWITZ, SA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (01) : 61 - 67
  • [30] Comparison of a T1-weighted inversion-recovery-, gradient-echo- and spin-echo sequence for imaging of the brain at 3.0 Testa
    Stehling, C
    Niederstadt, T
    Krämer, S
    Kugel, H
    Schwindt, W
    Heindel, W
    Bachmann, R
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2005, 177 (04): : 536 - 542