Cleaning Initiation Criteria for Heating, Ventilation and Air-Conditioning (HVAC) Systems in Non-Industrial Buildings

被引:0
|
作者
Lavoie, Jacques [1 ]
Bahloul, Ali [1 ]
Clouttier, Yves [1 ]
机构
[1] Inst Rech Robert Sauve Sante & Secur Travail, Res Dept, Montreal, PQ, Canada
来源
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
In the United States and Canada, the initiation of air system cleaning is based on visual inspection, which is subjective and impractical fir major cleaning work. The association for the prevention and study of contamination (A SPEC) in France has published a guide on objective sampling methods (numerical evaluation method) for keeping non-porous air systems clean. However; the sampling methods have some deficiencies. The objectives of this study were to reproduce in the laboratory different levels of cleanliness in non-porous ducts of HVAC systems, to compare a new method for sampling sum face dust in ducts with those methods cited in the literature, and to compare the numerical evaluation method (objective method) to the visual method (subjective one). For each of the simulated cleanliness conditions, a committee of specialists did a visual assessment based on a scale of 3, where level I meant normal, 2 meant above normal, and 3 meant serious. According to these assessments, the established initiation criteria correspond to 0.2 grams per square meter (0.00066 ounces per square foot) for the NADCA method, 0.3 g/m(2) (0.00098 oz/ft(2)) for the ASPEC method, and 0.6 g/m(2) (0.002 oz/ft(2)) for the new method. These criteria are significantly different (p <= 0.05) from one another. When replacing the visual method, any of the surface sampling methods can be used, insofar as the corresponding initiation criterion is applied, but these results need to be evaluated in real ducts with real dust before being used as cleaning initiation criteria.
引用
收藏
页码:476 / +
页数:4
相关论文
共 50 条
  • [41] Heating, ventilation and air conditioning (HVAC) in intensive care unit
    Saran, Sai
    Gurjar, Mohan
    Baronia, Arvind
    Sivapurapu, Vijayalakshmi
    Ghosh, Pralay S.
    Raju, Gautham M.
    Maurya, Indubala
    CRITICAL CARE, 2020, 24 (01)
  • [42] Heating, ventilation and air conditioning (HVAC) in intensive care unit
    Sai Saran
    Mohan Gurjar
    Arvind Baronia
    Vijayalakshmi Sivapurapu
    Pralay S. Ghosh
    Gautham M. Raju
    Indubala Maurya
    Critical Care, 24
  • [43] Performance assessment of variable frequency drives in heating, ventilation, and air-conditioning systems
    Wang, Gang
    Song, Li
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2018, 24 (10) : 1075 - 1083
  • [44] An Overview of Root Cause Analysis of Faults in Heating, Ventilation, and Air Conditioning (HVAC) Systems
    Hwang, Min Young
    Akinci, Burcu
    Berges, Mario
    COMPUTING IN CIVIL ENGINEERING 2021, 2022, : 1441 - 1448
  • [45] An internet of things upgrade for smart and scalable heating, ventilation and air-conditioning control in commercial buildings
    Png, Ethan
    Srinivasan, Seshadhri
    Bekiroglu, Korkut
    Jiang Chaoyang
    Rong Su
    Poolla, Kameshwar
    APPLIED ENERGY, 2019, 239 : 408 - 424
  • [46] Ventilation and air-conditioning systems in the meat industry
    Muller, JH
    FLEISCHWIRTSCHAFT, 1996, 76 (02): : 134 - 135
  • [47] SOUND PROOFING FOR VENTILATION AND AIR-CONDITIONING SYSTEMS
    SCHMIDT, H
    KALTE UND KLIMATECHNIK, 1979, 32 (11): : 632 - &
  • [48] Virtual Hardware-in-the-Loop FMU Co-Simulation Based Digital Twins for Heating, Ventilation, and Air-Conditioning (HVAC) Systems
    Abrazeh, Saber
    Mohseni, Saeid-Reza
    Zeitouni, Meisam Jahanshahi
    Parvaresh, Ahmad
    Fathollahi, Arman
    Gheisarnejad, Meysam
    Khooban, Mohammad-Hassan
    IEEE TRANSACTIONS ON EMERGING TOPICS IN COMPUTATIONAL INTELLIGENCE, 2023, 7 (01): : 65 - 75
  • [49] HEATING AND AIR-CONDITIONING OF BUILDINGS - FABER,O, KELL,JR
    不详
    ROYAL SOCIETY OF HEALTH JOURNAL, 1957, 77 (06): : 282 - 282
  • [50] Application study of heating and air-conditioning equipment in residential buildings
    Xu, W.L.
    Nuantong Kongtiao/HV & AC, 2001, 31 (04):