Cleaning Initiation Criteria for Heating, Ventilation and Air-Conditioning (HVAC) Systems in Non-Industrial Buildings

被引:0
|
作者
Lavoie, Jacques [1 ]
Bahloul, Ali [1 ]
Clouttier, Yves [1 ]
机构
[1] Inst Rech Robert Sauve Sante & Secur Travail, Res Dept, Montreal, PQ, Canada
来源
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
In the United States and Canada, the initiation of air system cleaning is based on visual inspection, which is subjective and impractical fir major cleaning work. The association for the prevention and study of contamination (A SPEC) in France has published a guide on objective sampling methods (numerical evaluation method) for keeping non-porous air systems clean. However; the sampling methods have some deficiencies. The objectives of this study were to reproduce in the laboratory different levels of cleanliness in non-porous ducts of HVAC systems, to compare a new method for sampling sum face dust in ducts with those methods cited in the literature, and to compare the numerical evaluation method (objective method) to the visual method (subjective one). For each of the simulated cleanliness conditions, a committee of specialists did a visual assessment based on a scale of 3, where level I meant normal, 2 meant above normal, and 3 meant serious. According to these assessments, the established initiation criteria correspond to 0.2 grams per square meter (0.00066 ounces per square foot) for the NADCA method, 0.3 g/m(2) (0.00098 oz/ft(2)) for the ASPEC method, and 0.6 g/m(2) (0.002 oz/ft(2)) for the new method. These criteria are significantly different (p <= 0.05) from one another. When replacing the visual method, any of the surface sampling methods can be used, insofar as the corresponding initiation criterion is applied, but these results need to be evaluated in real ducts with real dust before being used as cleaning initiation criteria.
引用
收藏
页码:476 / +
页数:4
相关论文
共 50 条
  • [31] Mobile Inspection Robot for Heating, Ventilation and Air Conditioning (HVAC) Ducting Systems
    Hisham, Amirah Aisha Badrul
    Xuan, Wong Liang
    Ishak, Mohamad Hafis Izran
    Idris, Nurul Hawani
    Nawi, Abdullah Mohd
    JURNAL TEKNOLOGI, 2015, 73 (06):
  • [32] Criteria for the selection of control valves for central heating and air-conditioning systems
    Gottfried, Knabe
    HLH Dusseldorf, 1997, 48 (05): : 54 - 60
  • [33] Flexible operation of active distribution network using integrated smart buildings with heating, ventilation and air-conditioning systems
    Jiang, Tao
    Li, Zening
    Jin, Xiaolong
    Chen, Houhe
    Li, Xue
    Mu, Yunfei
    APPLIED ENERGY, 2018, 226 : 181 - 196
  • [34] HEATING, VENTILATION AND AIR CONDITIONING OF BUILDINGS MONUMENT
    Muntea, Cornel
    Domnita, Florin
    NANO, BIO AND GREEN - TECHNOLOGIES FOR A SUSTAINABLE FUTURE CONFERENCE PROCEEDINGS, SGEM 2016, VOL II, 2016, : 593 - 600
  • [35] METERS FOR AIR-CONDITIONING AND HEATING SYSTEMS
    不详
    KALTE UND KLIMATECHNIK, 1978, 31 (07): : 314 - 315
  • [36] State of the art review on model predictive control (MPC) in Heating Ventilation and Air-conditioning (HVAC) field
    Yao, Ye
    Shekhar, Divyanshu Kumar
    BUILDING AND ENVIRONMENT, 2021, 200
  • [37] Faber & Kell's Heating & Air-conditioning of Buildings
    Sherratt, A. F. C.
    INTERNATIONAL JOURNAL OF AMBIENT ENERGY, 2008, 29 (02) : 110 - 111
  • [38] Capability of air filters to retain airborne bacteria and molds in heating, ventilating and air-conditioning (HVAC) systems
    Möritz, M
    Peters, H
    Nipko, B
    Rüden, H
    INTERNATIONAL JOURNAL OF HYGIENE AND ENVIRONMENTAL HEALTH, 2001, 203 (5-6) : 401 - 409
  • [39] Heat-/ventilation engineering. Dimensioning of heating and air-conditioning systems
    Vajda, József
    HLH Heizung Luftung/Klima Haustechnik, 1999, 50 (12): : 34 - 36
  • [40] Exergy Analysis of a Heating Ventilation and Air Conditioning (HVAC) System
    Prakash, K.
    Islam, F. R.
    Mamun, K. A.
    Sharma, A.
    Sen, A.
    2018 IEEE 7TH INTERNATIONAL CONFERENCE ON POWER AND ENERGY (PECON), 2018, : 378 - 383