FlyEyes: A CCD-based Wavefront Sensor for PUEO, the CFHT Curvature AO System

被引:0
|
作者
Lai, Olivier [1 ]
Cuillandre, Jean-Charles [1 ]
Ho, Kevin K. Y. [1 ]
Baril, Marc [1 ]
Benedict, Tom [1 ]
Ward, Jeff [1 ]
Thomas, Jim [1 ]
Salmon, Derrick [1 ]
Lin, Chueh-Jen [2 ]
Wang, Shiang-Yu [2 ]
Luppino, Gerry [3 ]
Dorn, Reinhold [4 ]
Puget, Pascal [5 ]
Burke, Barry [6 ]
Beletic, James [7 ]
机构
[1] Canada France Hawaii Telescope Corp, 65-1238 Mamalahoa Highway, Kamuela, HI 96743 USA
[2] Natl Taiwan Univ, Inst Astron & Astrophys, Taipei 10617, Taiwan
[3] GL Sci, Honolulu, HI 96816 USA
[4] European So Observ, D-85748 Garching, Germany
[5] Lab Astrophys Observ Grenoble, F-38041 Grenoble, France
[6] MIT, Lincoln Lab, Lexington, MA 02420 USA
[7] Teledyne Imaging Sensors, Camarillo, CA 93102 USA
关键词
D O I
10.1086/659149
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
Adaptive optics wavefront sensing imposes stringent requirements on detectors, due to the simultaneous need for extremely low read noise and high frame rates. Curvature wavefront sensing measurements are based on the normalized intensity of the signal in a given subaperture, and avalance photodiodes (APDs) have traditionally been used as detectors in curvature systems such as the Canada-France-Hawaii Telescope (CFHT) adaptive optics (AO) bonnette, called PUEO after the endemic Hawaiian owl. Passively quenched APDs are robust but have low QE (similar to 40%), while actively quenched APDs can have much higher QE, but have been known to fail. Furthermore, curvature systems with large numbers of subapertures are now in operation, and the cost of individual APDs may become prohibitive for such systems. Thus, a CCD-based alternative appears very attractive, and development of a specific chip was initiated at ESO 10 years ago. In this article, we report on the performance of the Fly Eyes camera, a project that was conceived to compare the performance of the backside-illuminated custom-designed CCD detector with an array of APDs, used in an operational and well-characterized curvature wavefront AO system. The on-sky performance is demonstrated to be unaffected on bright guide stars (i.e., negligible latency), and although the faint end suffers from the 2.5 e(-) read noise, the performance can be regained by lowering the frame rate on the wavefront sensor. In this article, we report on results that show that the CCD can be used to replace an array of expensive APDs. This would enable a cost-effective upgrade of PUEO to a higher-order system, as has been proposed at various occasions.
引用
收藏
页码:448 / 460
页数:13
相关论文
共 50 条
  • [31] A CCD-BASED SYSTEM FOR ANALYSIS OF NUCLEAR COLLISIONS IN PHOTOGRAPHIC-EMULSION
    ANGIUS, SP
    ELMER, R
    JAKOBSSON, B
    KARLSSON, L
    SODERSTROM, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1992, 63 (03): : 359 - 365
  • [32] CCD-based detection system for immunity-chromatography test strip
    Liu, Lei
    Zhou, Lei
    Huang, Lihua
    Yan, Zhongqiang
    Zhao, Yongkai
    Yang, Ruifu
    Zeng, Aijun
    Yu, Kun
    Huang, Huijie
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2007, 28 (02): : 246 - 251
  • [33] CCD-based two-dimensional pneumatic arm control system
    Wang, Y-T
    Wong, R-H
    Lo, J-H
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART I-JOURNAL OF SYSTEMS AND CONTROL ENGINEERING, 2009, 223 (I5) : 585 - 590
  • [34] A SIMPLE AND LOW-COST CCD-BASED IMAGING-SYSTEM
    SLESSOR, MD
    GREEN, SI
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1992, 3 (04) : 421 - 423
  • [35] Upgrading the MMT AO system with a Near-Infrared Pyramid Wavefront Sensor
    Liu, Siqi
    Sivanandam, Suresh
    Chen, Shaojie
    Lamb, Masen
    Butko, Adam
    Veran, Jean-Pierre
    Hinz, Phil
    Mieda, Etsuko
    Hardy, Tim
    Lardiere, Olivier
    Shore, Eric
    ADAPTIVE OPTICS SYSTEMS VI, 2018, 10703
  • [36] A CCD-based system for the detection of DNA in electrophoresis gels by UV absorption
    Mahon, AR
    MacDonald, JH
    Ott, RJ
    Mainwood, A
    PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (06): : 1529 - 1541
  • [37] Improvements to the three-color optical CCD-based pyrometer system
    Fu, Tairan
    Zhao, Huan
    Zeng, Jun
    Wang, Zhe
    Zhong, Maohua
    Shi, Congling
    APPLIED OPTICS, 2010, 49 (31) : 5997 - 6005
  • [38] Testing system of CCD-based measuring optical property of chromatic display
    Yu, TH
    Dai, JM
    Liu, Y
    Jia, LJ
    PROCEEDINGS OF THE THIRD INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION SCIENCE AND TECHNOLOGY, VOL 2, 2004, : 1358 - 1361
  • [39] Proposal for measuring the quantum states of neutrons in the gravitational field with a CCD-based pixel sensor
    Sanuki, T.
    Komamiya, S.
    Kawasaki, S.
    Sonoda, S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 600 (03): : 657 - 660
  • [40] Optimization of CCD-Based Gated-Viewing System for Low Illumination Conditions
    Seyfi, Natalia A.
    Golitsyn, Alexandr A.
    Golitsyn, Andrey, V
    2019 20TH INTERNATIONAL CONFERENCE OF YOUNG SPECIALISTS ON MICRO/NANOTECHNOLOGIES AND ELECTRON DEVICES (EDM 2019), 2019, : 313 - 316