A CCD-BASED SYSTEM FOR ANALYSIS OF NUCLEAR COLLISIONS IN PHOTOGRAPHIC-EMULSION

被引:7
|
作者
ANGIUS, SP [1 ]
ELMER, R [1 ]
JAKOBSSON, B [1 ]
KARLSSON, L [1 ]
SODERSTROM, K [1 ]
机构
[1] UNIV LUND,DEPT PHYS,S-22362 LUND,SWEDEN
关键词
D O I
10.1016/0168-583X(92)95120-G
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A CCD-based system for reading and analyzing nuclear emulsion pictures is described. Profile and area measurements on tracks produced by stopping nuclei with charge 1 to 79 are presented. The charge resolution is ranging from DELTA-Z/Z less-than-or-equal-to 0.6 at a residual range of 100-mu-m to DELTA-Z/Z less-than-or-equal-to 0.3 at 200-mu-m for all charges.
引用
收藏
页码:359 / 365
页数:7
相关论文
共 50 条
  • [1] RADIOSTIMULATED INCREASE OF SENSITIVITY OF NUCLEAR PHOTOGRAPHIC-EMULSION IN AUTORADIOGRAPHY
    RUSOV, VD
    ZELENTSOVA, TN
    SEMENOV, MY
    ZAKHAROV, VI
    KRAVCHENKO, SN
    ZHURNAL NAUCHNOI I PRIKLADNOI FOTOGRAFII, 1987, 32 (06): : 401 - 408
  • [2] RELATIVISTIC NUCLEAR PHOTOGRAPHIC-EMULSION FOR LARGE VOLUME PILES
    BOGOMOLOV, KS
    ROMANOVSKAYA, KM
    RAZORENOVA, IF
    VETCHINKINA, ZI
    MYLTSEVA, VA
    ZHURAVLEV, DA
    KONDRATEVA, MA
    NYMMIK, RA
    CHIKOVA, LO
    PRIBORY I TEKHNIKA EKSPERIMENTA, 1975, (05): : 63 - 65
  • [3] CCD-based astrometric measurement of photographic plates
    Fierro, IHB
    Calderón, JH
    REVISTA MEXICANA DE ASTRONOMIA Y ASTROFISICA, 2003, 39 (02) : 303 - 310
  • [4] METHOD OF GRAIN COUNTING FOR IDENTIFICATION OF NUCLEAR TRACKS IN DILUTED PHOTOGRAPHIC-EMULSION
    DITLOV, VA
    BRADNOVA, V
    RADIATION MEASUREMENTS, 1995, 24 (02) : 145 - 151
  • [5] A CCD-based tissue imaging system
    MacDonald, JH
    Wells, K
    Reader, AJ
    Ott, RJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 392 (1-3): : 220 - 226
  • [6] EMPIRICAL DENSITY-FUNCTION ANALYSIS OF PHOTOGRAPHIC-EMULSION GRADIENT CURVES
    PITT, DA
    RACHU, ML
    SAHYUN, MRV
    PHOTOGRAPHIC SCIENCE AND ENGINEERING, 1977, 21 (06): : 331 - 335
  • [7] SYSTEM-ANALYSIS OF CCD-BASED BAR CODE READERS
    TSI, D
    MAROM, E
    KATZ, J
    SWARTZ, J
    APPLIED OPTICS, 1993, 32 (19): : 3504 - 3512
  • [8] FORTRAN-BASED PHOTOGRAPHIC-EMULSION CALIBRATION PROCEDURE FOR USE IN QUANTITATIVE SPECTROMETRY
    HOLCOMBE, JA
    BRINKMAN, DW
    SACKS, RD
    ANALYTICAL CHEMISTRY, 1975, 47 (03) : 441 - 447
  • [9] REPRESENTATION OF THE PHOTOGRAPHIC-EMULSION CALIBRATION GRAPH IN EMISSION SPECTROGRAPHIC ANALYSIS BY A SIMPLIFIED FORMULA
    SHOAEB, AM
    HELMI, MS
    ELSHERBINEY, EM
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1986, 1 (02) : 157 - 159
  • [10] Evaluation of a CCD-based tissue imaging system
    MacDonald, JH
    Wells, K
    Ott, RJ
    1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 1458 - 1461