Comparison between MDCT and Grayscale IVUS in a Quantitative Analysis of Coronary Lumen in Segments with or without Atherosclerotic Plaques

被引:3
|
作者
Falcao, Joao L. A. A. [1 ]
Falcao, Breno A. A. [1 ]
Gurudevan, Swaminatha V. [2 ]
Campos, Carlos M. [1 ]
Silva, Expedito R. [1 ]
Kalil-Filho, Roberto [1 ]
Rochitte, Carlos E. [1 ]
Shiozaki, Afonso A. [1 ]
Coelho-Filho, Otavio R. [1 ]
Lemos, Pedro A. [1 ]
机构
[1] Univ Sao Paulo, Heart Inst InCor, Med Sch USP, Sao Paulo, SP, Brazil
[2] Cedars Sinai Heart Inst, Los Angeles, CA USA
基金
巴西圣保罗研究基金会;
关键词
Coronary Artery Disease; Plaque; Atherosclerotic; /; diagnosis; Multidetector Computed Tomography / utilization; Ultrasonography; utilization; MULTISLICE COMPUTED-TOMOGRAPHY; INTRAVASCULAR ULTRASOUND; CT ANGIOGRAPHY; 64-MDCT ANGIOGRAPHY; STENOSIS; METAANALYSIS; ACCURACY; STANDARD;
D O I
10.5935/abc.20140211
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The diagnostic accuracy of 64-slice MDCT in comparison with IVUS has been poorly described and is mainly restricted to reports analyzing segments with documented atherosclerotic plaques. Objectives: We compared 64-slice multidetector computed tomography (MDCT) with gray scale intravascular ultrasound (IVUS) for the evaluation of coronary lumen dimensions in the context of a comprehensive analysis, including segments with absent or mild disease. Methods: The 64-slice MDCT was performed within 72 h before the IVUS imaging, which was obtained for at least one coronary, regardless of the presence of luminal stenosis at angiography. A total of 21 patients were included, with 70 imaged vessels (total length 114.6 +/- 38.3 mm per patient). A coronary plaque was diagnosed in segments with plaque burden > 40%. Results: At patient, vessel, and segment levels, average lumen area, minimal lumen area, and minimal lumen diameter were highly correlated between IVUS and 64-slice MDCT (p < 0.01). However, 64-slice MDCT tended to underestimate the lumen size with a relatively wide dispersion of the differences. The comparison between 64-slice MDCT and IVUS lumen measurements was not substantially affected by the presence or absence of an underlying plaque. In addition, 64-slice MDCT showed good global accuracy for the detection of IVUS parameters associated with flow-limiting lesions. Conclusions: In a comprehensive, multi-territory, and whole-artery analysis, the assessment of coronary lumen by 64-slice MDCT compared with coronary IVUS showed a good overall diagnostic ability, regardless of the presence or absence of underlying atherosclerotic plaques.
引用
收藏
页码:315 / 322
页数:8
相关论文
共 50 条
  • [41] Comparison of quantitative analysis of finger and forearm movements between early stage Parkinson's disease and scans without evidence of dopaminergic deficit (SWEDD)
    Kwon, D. Y.
    Park, M. H.
    Kim, J. W.
    MOVEMENT DISORDERS, 2018, 33 : S512 - S512
  • [42] Comparison of quantitative analysis of hand movements with gyroscope between early stage Parkinson's disease and scans without evidence of dopaminergic deficit (SWEDD)
    Ma, H. I.
    Kwon, D. Y.
    Park, M. H.
    Kang, J. H.
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2019, 405
  • [43] Comparison between minimum lumen cross-sectional area and intraluminal ultrasonic intensity analysis using integrated backscatter intravascular ultrasound for prediction of functionally significant coronary artery stenosis
    Takami, Hironori
    Sonoda, Shinjo
    Muraoka, Yoshitaka
    Miura, Toshiya
    Shimizu, Akiyoshi
    Anai, Reo
    Sanuki, Yoshinori
    Miyamoto, Tetsu
    Oginosawa, Yasushi
    Fujino, Yoshihisa
    Tsuda, Yuki
    Araki, Masaru
    Otsuji, Yutaka
    HEART AND VESSELS, 2019, 34 (02) : 208 - 217
  • [44] Comparison between minimum lumen cross-sectional area and intraluminal ultrasonic intensity analysis using integrated backscatter intravascular ultrasound for prediction of functionally significant coronary artery stenosis
    Hironori Takami
    Shinjo Sonoda
    Yoshitaka Muraoka
    Toshiya Miura
    Akiyoshi Shimizu
    Reo Anai
    Yoshinori Sanuki
    Tetsu Miyamoto
    Yasushi Oginosawa
    Yoshihisa Fujino
    Yuki Tsuda
    Masaru Araki
    Yutaka Otsuji
    Heart and Vessels, 2019, 34 : 208 - 217
  • [45] LACK OF CORRELATION BETWEEN AGE AND AMOUNTS OF CORONARY ARTERIAL NARROWING AMONG NECROPSY PATIENTS WITH FATAL CORONARY HEART-DISEASE - A QUALITATIVE AND QUANTITATIVE-ANALYSIS OF 906 MAJOR EPICARDIAL CORONARY-ARTERIES AND 7625 5 MM CORONARY SEGMENTS FROM 302 PATIENTS
    WALLER, BF
    ROBERTS, WC
    ARTERIOSCLEROSIS, 1981, 1 (01): : 62 - 63
  • [46] Feasibility of a novel radiofrequency signal analysis for in-vivo plaque characterization in humans: Comparison of plaque components between patients with and without acute coronary syndrome
    Kozuki, Amane
    Shinke, Toshiro
    Otake, Hiromasa
    Shite, Junya
    Matsumoto, Daisuke
    Kawamori, Hiroyuki
    Nakagawa, Masayuki
    Nagoshi, Ryoji
    Hariki, Hirotoshi
    Inoue, Takumi
    Nishio, Ryo
    Hirata, Ken-ichi
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 167 (04) : 1591 - 1596
  • [47] Comparison of clinical outcomes of intravascular ultrasound-calcified nodule between percutaneous coronary intervention with versus without rotational atherectomy in a propensity-score matched analysis
    Watanabe, Yusuke
    Sakakura, Kenichi
    Taniguchi, Yousuke
    Yamamoto, Kei
    Seguchi, Masaru
    Tsukui, Takunori
    Jinnouchi, Hiroyuki
    Wada, Hiroshi
    Momomura, Shin-ichi
    Fujita, Hideo
    PLOS ONE, 2020, 15 (11):
  • [48] Comparison between visual and semiquantitative analysis of the effect of attenuation correction with scatter compensation on the myocardial distribution of 99MTC MIBI in patients without coronary artery disease
    Pena, FJ
    Jimenez-Bonilla, J
    Banzo, I
    Guede, C
    Allende, RH
    Quirce, R
    Carril, JM
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (08): : 1002 - 1002
  • [49] Comparison between fractional flow reserve (FFR) and Computational fractional flow reserve derived from three-dimensional intravascular ultrasound (FFR-IVUS), percentage of diameter stenosis by visual estimation and bi-dimensional quantitative coronary angiography.
    Hideo-Kajita, Alexandre
    Garcia-Garcia, Hector
    Bezerra, Cristiano
    Pinton, Fabio A.
    Falcao, Breno
    Mariani, Jose, Jr.
    Bulant, Carlos
    Talou, Gonzalo Maso
    Filh Esteves, Antonio Esteves
    Blanco, Pablo
    Lemos, Pedro A.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (13) : B127 - B127
  • [50] Segmental Comparison between a Dedicated Bifurcation Stent and Balloon Angioplasty Using Intravascular Ultrasound and Three-Dimensional Quantitative Coronary Angiography: A Subgroup Analysis of the Tryton IDE Randomized Trial
    Grundeken, Maik J.
    Garcia-Garcia, Hector M.
    Kumsars, Indulis
    Lesiak, Maciej
    Kayaert, Peter
    Dens, Jo
    Stella, Pieter R.
    de Winter, Robbert J.
    Laak, Linda L.
    Genereux, Philippe
    Kaplan, Aaron V.
    Leon, Martin B.
    Wykrzykowska, Joanna J.
    Onuma, Yoshinobu
    Serruys, Patrick W.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2017, 89 (02) : E53 - E63