Comparison between MDCT and Grayscale IVUS in a Quantitative Analysis of Coronary Lumen in Segments with or without Atherosclerotic Plaques

被引:3
|
作者
Falcao, Joao L. A. A. [1 ]
Falcao, Breno A. A. [1 ]
Gurudevan, Swaminatha V. [2 ]
Campos, Carlos M. [1 ]
Silva, Expedito R. [1 ]
Kalil-Filho, Roberto [1 ]
Rochitte, Carlos E. [1 ]
Shiozaki, Afonso A. [1 ]
Coelho-Filho, Otavio R. [1 ]
Lemos, Pedro A. [1 ]
机构
[1] Univ Sao Paulo, Heart Inst InCor, Med Sch USP, Sao Paulo, SP, Brazil
[2] Cedars Sinai Heart Inst, Los Angeles, CA USA
基金
巴西圣保罗研究基金会;
关键词
Coronary Artery Disease; Plaque; Atherosclerotic; /; diagnosis; Multidetector Computed Tomography / utilization; Ultrasonography; utilization; MULTISLICE COMPUTED-TOMOGRAPHY; INTRAVASCULAR ULTRASOUND; CT ANGIOGRAPHY; 64-MDCT ANGIOGRAPHY; STENOSIS; METAANALYSIS; ACCURACY; STANDARD;
D O I
10.5935/abc.20140211
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The diagnostic accuracy of 64-slice MDCT in comparison with IVUS has been poorly described and is mainly restricted to reports analyzing segments with documented atherosclerotic plaques. Objectives: We compared 64-slice multidetector computed tomography (MDCT) with gray scale intravascular ultrasound (IVUS) for the evaluation of coronary lumen dimensions in the context of a comprehensive analysis, including segments with absent or mild disease. Methods: The 64-slice MDCT was performed within 72 h before the IVUS imaging, which was obtained for at least one coronary, regardless of the presence of luminal stenosis at angiography. A total of 21 patients were included, with 70 imaged vessels (total length 114.6 +/- 38.3 mm per patient). A coronary plaque was diagnosed in segments with plaque burden > 40%. Results: At patient, vessel, and segment levels, average lumen area, minimal lumen area, and minimal lumen diameter were highly correlated between IVUS and 64-slice MDCT (p < 0.01). However, 64-slice MDCT tended to underestimate the lumen size with a relatively wide dispersion of the differences. The comparison between 64-slice MDCT and IVUS lumen measurements was not substantially affected by the presence or absence of an underlying plaque. In addition, 64-slice MDCT showed good global accuracy for the detection of IVUS parameters associated with flow-limiting lesions. Conclusions: In a comprehensive, multi-territory, and whole-artery analysis, the assessment of coronary lumen by 64-slice MDCT compared with coronary IVUS showed a good overall diagnostic ability, regardless of the presence or absence of underlying atherosclerotic plaques.
引用
收藏
页码:315 / 322
页数:8
相关论文
共 50 条
  • [31] 128-Detector-Row Computed Tomography coronary angiography assessing differences in morphology and distribution of atherosclerotic plaques between patients with and without pre-test probability of significant coronary artery disease
    Lazoura, O.
    Vlychou, M.
    Vassiou, K.
    Kelekis, A.
    Kanavou, T.
    Thriskos, P.
    Fezoulidis, I. V.
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 77 (01) : 123 - 130
  • [32] COMPARISON OF THE EFFECTIVENESS OF LOVASTATIN THERAPY FOR HYPERCHOLESTEROLEMIA AFTER HEART-TRANSPLANTATION BETWEEN PATIENTS WITH AND WITHOUT PRETRANSPLANT ATHEROSCLEROTIC CORONARY-ARTERY DISEASE
    ANGUITA, M
    ALONSOPULPON, L
    ARIZON, JM
    CAVERO, MA
    VALLES, F
    SEGOVIA, J
    PEREZJIMENEZ, F
    CRESPO, M
    CONCHA, M
    AMERICAN JOURNAL OF CARDIOLOGY, 1994, 74 (08): : 776 - 779
  • [34] Comparison between different kernel reformatting filters in 3D quantitative analysis of MDCT coronary angiographyAccuratezza diagnostica della quantificazione automatica di stenosi coronarica (QCTA) mediante differenti filtri di convoluzione
    R. Malagò
    A. Pezzato
    C. Barbiani
    W. Mantovani
    G. Caliari
    U. Alfonsi
    D. Tavella
    R. Pozzi Mucelli
    La radiologia medica, 2011, 116 (8) : 1203 - 1216
  • [35] How to achieve DES-like results without drugs? Relation between atherosclerotic plaque and 6-month neolintimal volume in coronary artery specific stented segments using intravascular ultrasound
    Narbute, I
    Erglis, A
    Jegere, S
    Kumsars, I
    Kalnins, U
    AMERICAN JOURNAL OF CARDIOLOGY, 2003, 92 (6A): : 207L - 207L
  • [36] Quantitative Comparison of Blood and Blood Products Requirement between Two Groups with and without Auto-transfusion following Coronary Artery Bypass Grafting Surgery
    Soltanzadeh, Mansoor
    Ebadi, Ahmad
    Tabatabaiee, Seyed Kamaladin
    Firoozabadi, Mehdi Dehghani
    Firoozabadi, Mehdi Dehghani
    Mali, Shahriar
    Sheikhi, Mohammad Ali
    Ravanshadi, Farshid
    Nezamabadi, Vahid
    LIFE SCIENCE JOURNAL-ACTA ZHENGZHOU UNIVERSITY OVERSEAS EDITION, 2012, 9 (03): : 905 - 907
  • [37] The quantitative assessment of the rotation and twist of the left ventricle during dobutamine stress echocardiography-comparison between patients with and without significant coronary artery stenosis
    Mielczarek, A. J.
    Kasprzak, J. D.
    Lipiec, P.
    Wierzbowska-Drabik, K.
    EUROPEAN HEART JOURNAL, 2015, 36 : 602 - 602
  • [38] Quantitative analysis of angiographically border lesions in patients with stable coronary artery disease: Comparison between intravascular ultrasound, multislice computed tomography, and coronary angiography.
    Horszczaruk, GJ
    Kochman, J
    Roik, M
    Rdzanek, A
    Bakon, L
    Wilczynska, J
    Wretowski, D
    Gola, M
    Pietrasik, A
    Huczek, Z
    Pacho, R
    Opolski, G
    AMERICAN JOURNAL OF CARDIOLOGY, 2004, 94 (6A): : 165E - 165E
  • [39] Comparison of Two Contemporary Quantitative Atherosclerotic Plaque Assessment Tools for Coronary Computed Tomography Angiography: Single-Center Analysis and Multi-Center Patient Cohort Validation
    Weichsel, Loris
    Giesen, Alexander
    Andre, Florian
    Renker, Matthias
    Baumann, Stefan
    Breitbart, Philipp
    Beer, Meinrad
    Maurovitch-Horvat, Pal
    Szilveszter, Balint
    Vattay, Borbala
    Buss, Sebastian J.
    Marwan, Mohamed
    Giannopoulos, Andreas A.
    Kelle, Sebastian
    Frey, Norbert
    Korosoglou, Grigorios
    DIAGNOSTICS, 2024, 14 (02)
  • [40] RELATION OF SERUM TOTAL CHOLESTEROL AND TRIGLYCERIDE LEVELS TO THE AMOUNT AND EXTENT OF CORONARY ARTERIAL NARROWING BY ATHEROSCLEROTIC PLAQUE IN CORONARY HEART-DISEASE - QUANTITATIVE-ANALYSIS OF 2,037 5 MM SEGMENTS OF 160 MAJOR EPICARDIAL CORONARY-ARTERIES IN 40 NECROPSY PATIENTS
    CABIN, HS
    ROBERTS, WC
    AMERICAN JOURNAL OF MEDICINE, 1982, 73 (02): : 227 - 234