In vitro failure and fracture resistance of veneered and full-contour zirconia restorations

被引:70
|
作者
Preis, Verena [1 ]
Behr, Michael [1 ]
Hahnel, Sebastian [1 ]
Handel, Gerhard [1 ]
Rosentritt, Martin [1 ]
机构
[1] Univ Med Ctr Regensburg, Dept Prosthet Dent, D-93042 Regensburg, Germany
关键词
Zirconia; Full-contour; Surface treatment; Wear; Fracture resistance; FIXED-PARTIAL DENTURES; DENTAL PROSTHESES; Y-TZP; FRACTOGRAPHIC ANALYSES; SUBSTRUCTURE CERAMICS; LABORATORY SIMULATION; WEAR PERFORMANCE; BITE FORCE; STRENGTH; CROWNS;
D O I
10.1016/j.jdent.2012.07.010
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: This study evaluated the failure and fracture resistance of zirconia-based fixed partial dentures (FPDs) under the influence of different surface treatments and adjustment procedures. Methods: Seven groups (n = 8/group) of three-unit zirconia-based FPDs were fabricated in anatomic design (AD) or anatomically reduced design (ARD) and surfaces were prepared according to clinical relevance: #1: AD - sintered; #2: AD - sintered - glazed; #3: AD - sintered - sandblasted - glazed; #4: AD - sintered - polished - grinded (contact points adjusted); #5: AD - sintered - polished - grinded - repolished; #6: ARD - sintered - veneered; #7: control: analogous to #3 but without thermal cycling (TC) and mechanical loading (ML). FPDs were adhesively bonded to polymethylmethacrylate abutment teeth. TCML (TC: 6000 x 5 degrees/55 degrees; ML: 1.2 x 10(6) x 50 N, 1.6 Hz) was conducted in a chewing simulator with steatite spheres as antagonists. Failures were monitored and fracture resistance was determined after ageing. Data were analysed statistically with Mann-Whitney U-test (Kolmogorov-Smirnov-test; alpha = 0.05). FPDs were subjected to scanning electron microscopy for fractographic failure analysis. Results: None of the FPDs failed during TCML, but showed wear at contact points. Median fracture force ranged between 1173.5 N (#4) and 1316.0 N (#3) without significant (p = 0.910) differences between the groups or in comparison to the control (p > 0.462). Conclusions: Zirconia restorations showed high resistance to failures and fracture under different surface treatment variations. Full-contour polished or glazed zirconia FPDs might be an alternative to common veneered restorations. (c) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:921 / 928
页数:8
相关论文
共 50 条
  • [1] Fracture Resistance and Failure Mode of Monolithic Zirconia, Veneered Zirconia, and Metal-Ceramic Full-Coverage Restorations: A Comparative In Vitro Study
    Almohammed, Saleh N.
    Dourado, Annalita M.
    Al Quran, Firas A.
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2024, 37 (01) : 80 - 91
  • [2] In vitro performance of full-contour zirconia single crowns
    Beuer, Florian
    Stimmelmayr, Michael
    Gueth, Jan-Frederik
    Edelhoff, Daniel
    Naumann, Michael
    [J]. DENTAL MATERIALS, 2012, 28 (04) : 449 - 456
  • [3] Veneered Zirconia-Based Restorations Fracture Resistance Analysis
    Al-Wahadni, Ahed
    Shahin, Ahmad
    Kurtz, Kenneth S.
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2018, 27 (07): : 651 - 658
  • [4] Fracture Resistance of a Selection of Full-Contour All-Ceramic Crowns: An In Vitro Study
    Zesewitz, Tim F.
    Knauber, Andreas W.
    Nothdurft, Frank P.
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2014, 27 (03) : 264 - 266
  • [5] Fracture resistance of glazed, full-contour ZLS incisor crowns
    Schwindling, Franz Sebastian
    Rues, Stefan
    Schmitter, Marc
    [J]. JOURNAL OF PROSTHODONTIC RESEARCH, 2017, 61 (03) : 344 - 349
  • [6] Influence of cusp inclination and curvature on the in vitro failure and fracture resistance of veneered zirconia crowns
    Preis, Verena
    Dowerk, Thomas
    Behr, Michael
    Kolbeck, Carola
    Rosentritt, Martin
    [J]. CLINICAL ORAL INVESTIGATIONS, 2014, 18 (03) : 891 - 900
  • [7] Influence of cusp inclination and curvature on the in vitro failure and fracture resistance of veneered zirconia crowns
    Verena Preis
    Thomas Dowerk
    Michael Behr
    Carola Kolbeck
    Martin Rosentritt
    [J]. Clinical Oral Investigations, 2014, 18 : 891 - 900
  • [8] Effect of Glazing on Flexural Strength of Full-Contour Zirconia
    Kumchai, Hattanas
    Juntavee, Patrapan
    Sun, Arthur F.
    Nathanson, Dan
    [J]. INTERNATIONAL JOURNAL OF DENTISTRY, 2018, 2018
  • [9] Different Designs of Deep Marginal Elevation and Its Influence on Fracture Resistance of Teeth with Monolith Zirconia Full-Contour Crowns
    Robaian, Ali
    Alqahtani, Abdullah
    Alanazi, Khalid
    Alanazi, Abdulrhman
    Almalki, Meshal
    Aljarad, Anas
    Albaijan, Refal
    Maawadh, Ahmed
    Sufyan, Aref
    Mirza, Mubashir Baig
    [J]. MEDICINA-LITHUANIA, 2023, 59 (04):
  • [10] Impact of multiple firings on fracture load of veneered zirconia restorations
    Hensel, Justine
    Reise, Michael
    Liebermann, Anja
    Buser, Ramona
    Stawarczyk, Bogna
    [J]. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2022, 130